Search results for "impression"

showing 10 items of 103 documents

Impression of multiple implants using photogrammetry: Description of technique and case presentation

2014

Aim: To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Study Design: Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abut - ments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 image…

MaleDental Impression TechniqueComputer sciencemedicine.medical_treatmentDentistryOdontologíaCase presentationProsthesismedicineHumansDental Impression TechniqueGeneral DentistryDental ImplantsEdentulismOral Medicine and Pathologybusiness.industryResearchSoft tissueMiddle Agedmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludImpressionPhotogrammetryOtorhinolaryngologyPhotogrammetryUNESCO::CIENCIAS MÉDICASSurgeryImplantbusinessMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Therapeutic Drug Monitoring for Patients With Alzheimer Dementia to Improve Treatment With Donepezil

2015

BACKGROUND Aiming to verify that therapeutic drug monitoring has the potential to optimize treatment with acetylcholine esterase inhibitors of patients with Alzheimer dementia, this study investigated whether serum concentrations of donepezil are associated with clinical improvement. METHODS Clinical improvement was measured using the clinical global impression (CGI) scale, and donepezil concentrations were measured in serum by a high-performance liquid chromatographic method with spectrophotometric detection. RESULTS In total, 206 serum samples from 106 patients (49.5% female) were retrospectively available for analysis. Patients included were treated under everyday conditions. Their mean …

MaleDrugmedicine.medical_specialtymedia_common.quotation_subjectGastroenterologyPiperidinesAlzheimer DiseaseInternal medicinemental disordersmedicineHumansDonepezilPharmacology (medical)DonepezilAgedRetrospective Studiesmedia_commonPharmacologyDose-Response Relationship DrugReceiver operating characteristicmedicine.diagnostic_testbusiness.industryRetrospective cohort studyAlzheimer dementiaDose–response relationshipTreatment OutcomeTherapeutic drug monitoringIndansClinical Global ImpressionFemaleCholinesterase InhibitorsDrug Monitoringbusinessmedicine.drugTherapeutic Drug Monitoring
researchProduct

[Variables associated with disability in elderly bipolar patients on ambulatory treatment].

2010

Introduction: Studies on adult bipolar patients have demonstrated a disability associated with the bipolar disorder, even in euthymic patients, but there is a lack of data in the elderly population. Material and method: A cross-sectional, multicentre study on a consecutive sample of ambulatory bipolar patients (DSM-IV-TR criteria), aged 65 years or over. Retrospective and cross-sectional sociodemographic and clinical data were collected, as well as the Clinical Global Impression for Bipolar Modified scale (CGI-BP-M) and the level of disability using the World Health Organisation Disability Assessment Schedule (WHO/DAS). The disability was assessed globally and by areas. The presence of a mo…

Malemedicine.medical_specialtyBipolar DisorderBipolar disorderCross-sectional studyMEDLINEDisability EvaluationElderlyAmbulatory caremental disordersmedicineAmbulatory CareHumansBipolar disorderAgedRetrospective StudiesDisabilitybusiness.industryMedical comorbidityRetrospective cohort studyGeneral Medicinemedicine.diseaseCross-Sectional StudiesAmbulatoryClinical Global ImpressionPhysical therapyFemalebusinessRevista de psiquiatria y salud mental
researchProduct

Serum concentrations of hydroxybupropion for dose optimization of depressed patients treated with bupropion.

2014

Background Bupropion is a dopamine and norepinephrine reuptake inhibitor approved for the treatment of depression and smoking cessation. According to the recently published reviews, it is a candidate for therapeutic drug monitoring (TDM) to improve therapeutic outcomes and reduce risks of intolerability or intoxication. In practice, however, the use of TDM is limited due to the chemical instability of bupropion. This investigation sought to determine if the major, active, and chemically stable metabolite 4-hydroxybupropion is a suitable measure to guide antidepressant drug therapy with bupropion. Methods 4-Hydroxybupropion serum levels were measured using a newly developed and validated hig…

Malemedicine.medical_specialtyUrologyNorepinephrine reuptake inhibitorPharmacokineticsmedicineHumansPharmacology (medical)BupropionChromatography High Pressure LiquidRetrospective StudiesPharmacologyBupropionDepressive Disordermedicine.diagnostic_testbusiness.industryTherapeutic effectHydroxybupropionMiddle AgedTherapeutic drug monitoringArea Under CurveClinical Global ImpressionAntidepressantAntidepressive Agents Second-GenerationFemalebusinessmedicine.drugHalf-LifeTherapeutic drug monitoring
researchProduct

Association between alcoholism and symptom expression, patient symptom goals, and clinical response in advanced cancer patients

2019

Aim: The aim of this study was to determine the influence of alcoholism on symptom expression, personalized symptom goal (PSG) and patient goal response (PGR), and patient global impression (PGI) in advanced cancer patients. Methods: This was a secondary analysis of an international multicenter study. Advanced cancer patients who had a history of alcohol dependence positive, according to CAGE (cut down, annoy, guilt, eye-opener), were selected. Thirty patients (3.45%) were CAGE-positive. This sample was matched with 30 patients with similar characteristics who were CAGE-negative. Patients rated symptom intensity by using the Edmonton Symptom Assessment Score (ESAS) at admission (T0) and the…

Malemedicine.medical_specialtyWeaknessPalliative careNauseaPain medicine03 medical and health sciences0302 clinical medicineNeoplasmsStatistical significanceInternal medicinemental disordersHumansMedicine030212 general & internal medicineAgedGlobal impressionbusiness.industryMinimal clinically important differenceAlcohol dependencePatients’ goalAdvanced cancerAdvanced cancer patientAlcoholismOncology030220 oncology & carcinogenesisClinical responseSymptom burdenFemalelipids (amino acids peptides and proteins)Symptom Assessmentmedicine.symptombusinessGoals
researchProduct

Positron Microscopy Studies of Wear Tracks on a Copper Surface

2014

Positron microscopy was used for studies of defects induced by ball indentation or sliding on the surface of well-annealed copper samples. A focused positron beam of 24.5-keV energy was used to scan the deformed region of the indenter impression, and measurements of the annihilation line parameter were performed. In the case of ball indentation, the measured defect distribution correlates well with the von Mises stress distribution of the Hertz contact and the von Mises yield criterion. For the wear track produced by pin on disc dry sliding, an asymmetric defect distribution near the wear track is observed. It indicates the presence of a tangential force that additionally deforms the sample.

Materials scienceAnnihilationMechanical Engineeringchemistry.chemical_elementSurfaces and InterfacesCopperImpressionSurfaces Coatings and FilmsPositronchemistryMechanics of MaterialsIndentationMicroscopyBall (bearing)Forensic engineeringvon Mises yield criterionComposite materialTribology Letters
researchProduct

Improving PMMA resin using graphene oxide for a definitive prosthodontic rehabilitation - A clinical report

2019

The use of acrylic resins as a definitive material has shown some advantages comparing to other definitive materials. However, their poor mechanical properties remain a major drawback. In this case report, graphene oxide (GO) was incorporated into polymethyl methacrylate (PMMA) resin for a definitive maxillary rehabilitation, combined with an intraoral digital impression and a three-dimensional facial scan. After 8 months of the placement of the definitive prosthesis, no mechanical, aesthetic, or biologic complications were reported, and the soft tissues showed excellent health and stability. The incorporation of GO in PMMA resins seems to be a suitable option for prosthetic rehabilitation.…

Materials sciencemedicine.medical_treatmentOxideDentistryCase ReportProsthesislaw.invention03 medical and health scienceschemistry.chemical_compound0302 clinical medicineClinical reportlawmedicineDental Impression TechniqueGeneral DentistryAcrylic resin030304 developmental biologyProsthetic Dentistry0303 health sciencesbusiness.industryGrapheneDental prosthesistechnology industry and agriculture030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Impressionchemistryvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumbusinessJournal of Clinical and Experimental Dentistry
researchProduct

A holistic approach to design for 4D Printing

2019

Invented in 1983, as a rapid prototyping process, additive manufacturing (AM) is nowadays considered as a manufacturing process almost in the same way as conventional processes. For example, parts obtained by AM are found in aircraft structures. This AM evolution is mainly due to the shape complexity allowed by the process. The driving forces behind this evolution include: the development of various techniques on the layer-wise manufacturing principle and the improvement both in quantity and quality of the range of materials that can be processed. Many other AM techniques and materials continue to emerge. In the wake of the AM (usually referred to as 3D printing) another mode of manufacturi…

Matériaux intelligentsFabrication additiveConception pour l’impression 4DAdditive manufacturingDfamDesign for 4D Printing (Df4DP)Voxel-Based modelingSmart materials4D printingImpression 4D[PHYS.MECA.MEMA]Physics [physics]/Mechanics [physics]/Mechanics of materials [physics.class-ph][PHYS.MECA.MEMA] Physics [physics]/Mechanics [physics]/Mechanics of materials [physics.class-ph]Modélisation à base de voxelsConception pour la fabrication additive
researchProduct

Proactive design and formalization of related spatiotemporal knowledge : application to assembly process and additive manufacturing with smart materi…

2019

...

MéréotopologieMatériaux intelligentsProactive designFabrication additiveVoxelOntologyAdditive manufacturing[SPI] Engineering Sciences [physics]Smart materialsOntologie4D printingPLMMereotopologyConception proactiveImpression 4D[SPI.MECA.GEME]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph][SPI]Engineering Sciences [physics]Advanved CADCAO avancéeVoxels[SPI.MECA.GEME] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]
researchProduct

Intégration proactive des métiers en conception et formalisation des connaissances spatio-temporelles associées : application à l'assemblage et à la …

2019

...

MéréotopologieProactive design[SPI] Engineering Sciences [physics]Additive manufacturingadvanced CADOntologie4D printingconception pour l'X[SPI.MECA] Engineering Sciences [physics]/Mechanics [physics.med-ph]PLM[SPI]Engineering Sciences [physics]CAO avancéeontologies[SPI.MECA.GEME] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]design for XMatériaux intelligentsFabrication additiveVoxelOntologySmart materials[SPI.MECA]Engineering Sciences [physics]/Mechanics [physics.med-ph]MereotopologyConception proactiveImpression 4D[SPI.MECA.GEME]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]Advanved CADVoxels
researchProduct