Search results for "ingegneria"
showing 10 items of 1227 documents
External knowledge sourcing for R&D activities: antecedents and implications of governance mode choice
2014
This paper investigates how internal and external factors affect the choice between alliances and joint ventures (A&JVs) and mergers and acquisitions (M&As) for the external sourcing of research and development (R&D) activities, and whether or not such a choice is really con- tingent, that is, is it the best choice in terms of its impact on firms’ innovative performance under those circumstances? We build a set of hypotheses based on both the transaction-cost theory and the resource-based view, and test them through a secondary data source analy- sis. We found that companies adopt either R&D M&A or A&JV depending on internal (e.g. resources and capabilities, innovation experience) and exter…
A model for predicting the mixed-mode fatigue crack growth in a bonded joint
2013
Bonded joints are highly sensitive to the presence of defects and to the degradation phenomena, and this aspect represents the primary obstacle to their use in different structural engineering applications. Delamination in a bonded joint represents, in fact, one of the primary, most common and insidious causes of damage. In this paper, a numerical–experimental study on the crack propagation along the adhesive layer of a bonded joint specimen is carried out. Experimental study is focused on the evaluation of the damage modalities of a bonded joint when the specimens are subject to fatigue load. Experimental tests are compared with the results of several numerical analysis performed in ANSYS …
Influence on the transient evoked otoacoustic emission by GSM 915 MHz electromagnetic fields: comparative analysis between control and exposed groups
2006
Modelling biological nitrogen and phosphorus removal with soluble microbial products (SMP) production-degradation processes
2011
Over the last two decades, Membrane Bioreactors (MBR) are increasingly used for wastewater treatment. Mathematical modelling of MBR systems has played a key role in order to better explain the effect of their peculiarities. Indeed, several MBR models have been presented in literature in order to improve the knowledge on MBR systems: biological models, hybrid models which include soluble microbial product (SMP) modelling, physical models able to describe the membrane fouling and integrated models which couple the hybrid models with the physical ones. However, among the existing MBR models only few integrated models have been developed which take into account the existing relationship between…
Towards a reduction of greenhouse gas emission from wastewater treatment plants: a new plant wide experimental and modelling approach
2016
The increasing interest in greenhouse gas (GHG) emissions from wastewater treatment plants (WWTPs) has led to the development of new tools for their design and management. Studies about gas emissions show that the sewer collection and the wastewater treatment plant are anthropogenic GHG potential sources, so they contribute to the climate change and air pollution. A wastewater treatment plant receives wastewater from sewers and, while produces treated water for discharge into surface water, emits the three major greenhouse gases, CO2, CH4, and N2O, during the treatment processes, and additional amounts of CO2 and CH4 from the energy demands (Bani Shahabadi et al., 2009). Indeed, energy cons…
Global sensitivity analysis in environmental water quality modelling: Where do we stand?
2014
Global sensitivity analysis (GSA) is a valuable tool to support the use of mathematical models for environmental systems. During the last years the water quality modelling field has embraced the use of GSA. Environmental water quality modellers have tried to transfer the knowledge and experience acquired in other disciplines. The main objective of this paper is to provide an informed problem statement of the issues surrounding GSA applications in the environmental water quality modelling field. Specifically, this paper aims at identifying, for each GSA method, the potential use, the critical issues to be solved and the limits identified in a comprehensive literature review. The paper shows …
Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach
2020
Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bo…
Influence of sutures configuration on the strength of tendon-patch joints for rotator cuff tears treatment
2019
Abstract Purpose Massive rotator cuff tears are common in the aging population. The incidence of failed rotator cuff repairs is still quite high, especially in the treatment of full-thickness tears or revision repairs. In this context, natural and synthetic meshes can be used as augmentation scaffolds or as devices to close the gap between a retracted tendon and the bone. The purpose of this work is to evaluate the ultimate tensile strength of different tendon-patch joints in order to consider their use in the treatment of massive cuff tears. Materials and methods Porcine tendons and a synthetic low-density polypropylene mesh have been used. A preliminary study on the tensile strength of te…
Biomechanical Analysis of a New Elbow Prosthesis
2019
Total elbow arthroplasty (TEA) is an effective and frequently used treatment for patients with debilitating elbow pathology. Total elbow prostheses have lagged behind those of the knee, hip and shoulder for different reasons, such as the high failure rate of the early designs. Concern remains regarding the longevity of TEA implants, especially in younger patients. The main cause of revision of the implant is usually related to the phenomenon of aseptic loosening mainly due to the cement-bone interface failure. Aim of this work is the biomechanical analysis of a new elbow prosthesis to investigate the mechanical behaviour at the cement-bone interface. For this reason, a musculoskeletal model…
Optimal positioning of the humeral component in the reverse shoulder prosthesis.
2014
Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. The main goal o…