Search results for "ingegneria"

showing 10 items of 1227 documents

Effect of Temperature on N2O and NO Emission in a Partial Nitrification SBR Treating Reject Wastewater

2017

Temperature is a very important parameter during nitritation, having a direct effect on ammonia oxidation rate (AOR) and enzymatic activities which relate to both N2O and NO emission. This study aims at investigating the effect of temperature on AOR, N2O and NO production in an enriched ammonia oxidizing bacteria (AOB) sequencing batch reactor (SBR) performing partial nitrification (PN) of synthetic reject wastewater. To achieve that, a SBR was subject to several shifts in temperature (in the range of 30 to 15 °C, 5 °C for each decrease). Cycle studies, which contain two aeration phases, were conducted under each temperature. The results showed that AOR specific exponentially correlates wit…

Ammonia oxidation rate Nitrous oxide Nitric oxide Reject wastewater TemperatureSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleInorganic chemistryNitrous OxideReject WastewaterTemperatureSequencing batch reactorAmmonia-oxidizing bacteriaNitrous oxideNitric Oxideequipment and suppliesPulp and paper industryAmmoniachemistry.chemical_compoundAmmonia Oxidation RatechemistryWastewaterNitrificationNo productionAeration
researchProduct

Anaerobic moving bed biofilm reactor followed by aerobic granular sludge for brewery wastewater treatment

2018

Small and medium breweries discharging to municipal sewers without treatment generate significant loads with typical concentrations reported by Valta et al. (2014) as 2-6 g COD L-1, 25-80 mg TN L-1, 10-50 mg TP L-1, with pH between 4.5 and 12. Treatment of the high-strength wastewater requires specialized low footprint processes, such as aerobic granular sludge (AGS), capable of high-rate degradation, as well as simultaneous nitrogen and phosphorous removal (Wang et al., 2007). The objective of this study was to evaluate the start-up period of AGS receiving brewery wastewater after initial anaerobic pre-treatment.

Anaerobic moving bed biofilm reactorSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleAerobic granular sludge
researchProduct

Investigating the level of significance of the coherence function in cardiovascular variability analysis

2002

Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), spectral estimator parameters should also be considered. In this study, the surrogate data technique was introduced to define the level of significance of the CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate the CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parame…

Analysis of covarianceThreshold limit valueFrequency domainStatistical significanceStatisticsSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaEstimatorCoherence (signal processing)Cardiology and Cardiovascular MedicineTransfer functionSoftwareMathematicsSurrogate data
researchProduct

Home-prepared anatase, rutile, and brookite TiO2 for selective photocatalytic oxidation of 4-methoxybenzyl alcohol in water: reactivity and ATR-FTIR …

2009

5th European Meeting on Solar Chemistry and Photocatalysis -- OCT 04-08, 2008 -- Palermo, ITALY

AnataseSettore ING-IND/24 - Principi Di Ingegneria ChimicaAldehydesCatalystsChemistryBrookiteInorganic chemistryAlcoholSelective photooxidation 4-methoxybenzylalcohol TiO2 ATR-FTIRP-anisaldehydeCatalysischemistry.chemical_compoundOrganic-chemistryGreen routeRutilevisual_artvisual_art.visual_art_mediumPhotocatalysisAqueous suspensionReactivity (chemistry)Partial oxidationSettore CHIM/07 - Fondamenti Chimici Delle TecnologiePhysical and Theoretical Chemistry
researchProduct

Photocatalytic thin films of TiO2 formed by a sol-gel process using titanium tetraisopropoxide as the precursor

2008

Abstract Thin TiO 2 films were prepared with the dip-coating technique by using sols deriving from titanium tetraisopropoxide. TiO 2 films were formed on glass substrates previously covered by a SiO 2 layer obtained from a tetraethylortosilicate sol. The films, after a thermal treatment at 673 K, mainly consisted of TiO 2 anatase. The samples were characterised by X-ray diffraction, UV–Vis spectroscopy, scanning electron microscopy and atomic force microscopy. The photoactivity of the various films was tested by using as probe reaction the photo-oxidation of 2-propanol in gas-solid regime. The photoreactivity results indicated that the TiO 2 films were efficient for degrading 2-propanol und…

AnataseSettore ING-IND/24 - Principi Di Ingegneria ChimicaMaterials sciencebusiness.industryScanning electron microscope2-Propanol photodegradation Dip-coating Structural properties Thin film Titanium dioxideMetals and AlloysSurfaces and InterfacesDip-coatingSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsTitanium oxidechemistry.chemical_compoundOpticsChemical engineeringchemistryTitanium dioxideMaterials ChemistryPhotocatalysisDip-coating Titanium dioxide Thin film 2-propanol Photodegradation Structural propertiesSettore CHIM/07 - Fondamenti Chimici Delle TecnologieThin filmbusinessSol-gel
researchProduct

Procedimento di preparazione di scaffolds polimerici preangiogenizzati.

2009

AngiogenesiSettore ING-IND/24 - Principi Di Ingegneria ChimicaECMIngeneria tessutaleRigenerazionePolimeriPLLA
researchProduct

In vitro Antifungal Activity of Biopolymeric Foam Activated with Carvacrol

2020

Background: Active packaging represents a defining strategy to improve food quality and safety of the packaged foods. This study aimed to evaluate the in vitro ability of commercial biopolymeric foams, namely Mater-Bi (MB), activated with 20% of carvacrol, to develop a completely biodegradable and compostable packaging to inhibit the growth of spoilage and pathogenic yeasts.
 Methods: MB foams, with and without carvacrol, were produced by melt mixing and the foaming process was performed in a laboratory press. The antifungal activity of foams containing carvacrol was tested applying the disk diffusion method. Statistical analysis was done using XLStat software version 7.5.2 for Excel.&…

Antifungallcsh:TP368-456Chemistrymedicine.drug_classcarvacrolSettore ING-IND/34 - Bioingegneria IndustrialeyeastsbiopolymersSettore AGR/15 - Scienze E Tecnologie AlimentariIn vitroBiopolymer Carvacrol Disk diffusion antimicrobial tests Food packaging Yeastslcsh:Food processing and manufacturechemistry.chemical_compoundSettore ING-IND/22 - Scienza E Tecnologia Dei Materialimedicinedisk diffusion antimicrobial testsCarvacrolFood sciencefood packagingSettore AGR/16 - Microbiologia AgrariaFood ScienceJournal of Food Quality and Hazards Control
researchProduct

Computer Modeling for the Prediction of Thoracic Aortic Stent Graft Collapse

2011

OBJECTIVE: To assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch. METHODS: One-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimen…

Aortic archMalemedicine.medical_specialtyAortographymedicine.medical_treatmentHemodynamicsAorta ThoracicFOS: Medical engineeringProsthesis DesignAortographyBlood Vessel Prosthesis ImplantationImaging Three-DimensionalBlood vessel prosthesismedicine.arteryMaterials TestingmedicineHumansComputer Simulationthoracic aortic stent graft (TASG)Aortamedicine.diagnostic_testbusiness.industryEndovascular ProceduresHemodynamicsModels CardiovascularStentSettore ING-IND/34 - Bioingegneria Industrialenutritional and metabolic diseases90399 Biomedical Engineering not elsewhere classifiedCurvatures of the stomachSurgeryBiomechanical PhenomenaBlood Vessel ProsthesisProsthesis FailureEquipment Failure AnalysisRegional Blood FlowRadiographic Image Interpretation Computer-AssistedStentslipids (amino acids peptides and proteins)SurgeryStress Mechanicalbiological phenomena cell phenomena and immunitybusinessNuclear medicineTomography X-Ray ComputedCardiology and Cardiovascular MedicinePerfusionAlgorithmsJournal of Vascular Surgery
researchProduct

Framework for Fluid-Structure Interaction Analysis of Aortic Coarctation Resulting From Proximal Protusion of Thoracic Aortic Stent Graft Into the Ar…

2011

Thoracic aortic stent grafts (TASG) are commonly used to repair aortic anomalies or diseases in a minimally-invasive fashion. One complication of TASG is collapse, whereby blood is unable to completely flow through the graft as intended. Most TASG collapses occur in the setting of endovascular repair of traumatic thoracic aortic transection, where a typically smaller diameter aorta of pediatric patients is repaired with a relatively larger diameter endograft designed to treat aneurysmal disease [1]. It is hypothesized that the poor apposition of the leading edge of the proximal stent graft to the lesser curvature of the aortic arch can result increased hemodynamic force at the leading side …

Aortic archmedicine.medical_specialtyAortabusiness.industrymedicine.medical_treatmentaorti failureSettore ING-IND/34 - Bioingegneria IndustrialeHemodynamicsStentCurvatures of the stomachSurgeryAppositionsurgical procedures operativemedicine.arteryInternal medicineOcclusioncardiovascular systemCardiologyMedicinebusinessComplicationASME 2011 Summer Bioengineering Conference, Parts A and B
researchProduct

Corrigendum to Patterns of ascending aortic dilatation and predictors of surgical replacement of the aorta: A comparison of bicuspid and tricuspid ao…

2020

The authors regret that the author name of Romano and Raffa are incorrect. The corrected author's name are Romano G and Raffa GM. The authors would like to apologise for any inconvenience caused.

Aortic dilatationAortic valveAortamedicine.medical_specialtybusiness.industrySettore ING-IND/34 - Bioingegneria Industrialeaorta bicuspid aortic valvemedicine.anatomical_structuremedicine.arteryInternal medicinemedicineCardiologyCardiology and Cardiovascular MedicinebusinessMolecular Biology
researchProduct