Search results for "inocula"

showing 10 items of 206 documents

A QUANTITATIVE APPROACH TO THE EXPERIMENTAL TRANSMISSION SUCCESS OF ECHINOSTOMA FRIEDI (TREMATODA: ECHINOSTOMATIDAE) IN RATS

2006

Using a range of parameters, the ability of rats (Rattus norvegicus) to successfully transmit Echinostoma friedi to the next host was examined under experimental conditions. The concept of Experimental Transmission Success (TM), defined as the number of hosts that become successfully infected after exposure to a number of infective stages produced by a previous host per unit of inoculation at which this latter host was exposed, was introduced. Using data for the egg output and miracidium hatching and infectivity, the TM permits us to estimate the ability of a particular defintive host species to successfully transmit a parasite species. This concept may be also useful to compare the transmi…

MaleTime FactorsZoology:CIENCIAS DE LA VIDA [UNESCO]Echinostomatidaelaw.inventionRodent DiseasesInoculationlawCricetinaeEchinostomaUNESCO::CIENCIAS DE LA VIDAAnimalsParasite hostingRats WistarParasite Egg CountEcology Evolution Behavior and SystematicsLymnaeaOvumInfectivityEchinostomiasisMesocricetusbiologyHost (biology)EcologyHatchingHost:CIENCIAS DE LA VIDA::Biología animal (Zoología) ::Parasitología animal [UNESCO]biology.organism_classificationRatsUNESCO::CIENCIAS DE LA VIDA::Biología animal (Zoología) ::Parasitología animalTransmission (mechanics)Echinostoma ; Rats ; Inoculation ; HostEvaluation Studies as TopicParasitologyEchinostomaTrematodaJournal of Parasitology
researchProduct

Stereoacuity with balanced presbyopic contact lenses.

2010

Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…

MaleVisual acuitygenetic structuresContact LensesVisual AcuityContrast SensitivitymedicineHumansVision testDepth PerceptionVision BinocularVision TestsPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyEyeglassesReadingOftalmologíaOptometryFemalemedicine.symptomDepth perceptionPsychologyBinocular visionOptometryClinicalexperimental optometry
researchProduct

Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.

2011

Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…

MaleVisual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivitymedicineContrast (vision)HumansMathematicsmedia_commonAgedVision BinocularCross-Over StudiesColor VisionEquipment DesignPresbyopiaMiddle Agedeye diseasesStereoscopic acuityContact lensOphthalmologyStereopsisTreatment OutcomeOptometryFemalemedicine.symptomBinocular visionOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes.

2009

Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditio…

MaleVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentVisual AcuityIntraocular lensExtractionFunctional LateralityTratamiento médico0302 clinical medicineLens Implantation IntraocularMyopiaContrast (vision)MedicineRetinal-Detachmentmedia_commonVistaLenses IntraocularVision BinocularDistanceHigh myopiaRetinal detachmentGeneral MedicineMiddle AgedQualityTreatment OutcomeOftalmologíaFemalemedicine.symptomPhotopic visionRiskmedia_common.quotation_subjectProsthesis DesignContrast Sensitivity03 medical and health sciencesHumansMonocularPhacoemulsificationbusiness.industryMultifocal Iolmedicine.diseaseeye diseasesVisual PerformanceOphthalmology030221 ophthalmology & optometryOptometrysense organsbusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Visual and optical performance with the ReZoom multifocal intraocular lens

2011

Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…

Malemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityProsthesis DesignRefraction OcularContrast SensitivityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularWavefrontVision Binocularbusiness.industryAberrometryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyFemalemedicine.symptombusinessEuropean Journal of Ophthalmology
researchProduct

Prospective study of the Acri.LISA bifocal intraocular lens

2007

To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensCataractContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologyHumansMedicineContrast (vision)Prospective StudiesProspective cohort studyAgedmedia_commonLenses IntraocularVision BinocularPhacoemulsificationMonocularbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Impact of lens material on objective refraction in eyes with trifocal diffractive intraocular lenses

2021

Purpose: Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Methods: Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M…

Malemedicine.medical_specialtyPseudophakiaMesopic visionmedicine.medical_treatmentVisual AcuityUlls -- Acomodació i refraccióIntraocular lensRefraction OcularIntraocular lensesPupillaw.invention03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicinelawOphthalmologymedicineHumansPostoperative PeriodProspective StudiesMathematicsAgedEye -- Accomodation and refractionVision BinocularIntraocular lensOpticsTrifocal diffractiveLents intraocularsHydrofilicRefractionSubjective refractionMultifocal Intraocular LensesSensory SystemsLens (optics)OphthalmologyRefractionAutorefractorPatient SatisfactionDifracció030221 ophthalmology & optometryFemale:Ciències de la visió [Àrees temàtiques de la UPC]Diffraction030217 neurology & neurosurgeryHydrofobicPhotopic visionFollow-Up Studies
researchProduct

Intermediate visual function with different multifocal intraocular lens models

2009

Purpose To compare visual acuity at different distances after bilateral implantation of 1 of 4 multifocal intraocular lenses (IOLs). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods This study evaluated consecutive patients who had bilateral implantation of a spherical multifocal IOL with a +4.00 diopter (D) addition (add) (AcrySof ReSTOR SN60D3) or an aspheric multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), +3.75 D add (Acri.LISA 366D), or +3.00 D add (AcrySof ReSTOR SN6AD1). Six months postoperatively, binocular measurement of corrected distance visual acuity (CDVA) at 4 m, corrected near visual acuity (CNVA) at 40 cm, and corrected intermediate visual …

Malemedicine.medical_specialtyVisual acuityDistance visual acuityPseudophakiagenetic structuresVisual AcuityFunctional LateralityContrast SensitivityCorneaLens Implantation IntraocularCorneaOphthalmologymedicineHumansDioptreAgedLenses IntraocularVision Binocularbusiness.industryDistance PerceptionMiddle AgedMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureVisual functionOptometryFemaleSurgerysense organsmedicine.symptombusinessBinocular visionPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses.

2008

Purpose To compare visual acuity after bilateral implantation of 2 models of multifocal aspheric intraocular lenses (IOLs). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, and University of Valencia, Valencia, Spain. Methods Prospective study of patients who had bilateral implantation of an AcrySof ReSTOR SN6AD3 IOL (Group 1) or an Acri.LISA 366D IOL (Group 2). Six months postoperatively, binocular uncorrected and best corrected distance visual acuity, uncorrected-distance and best distance-corrected near visual acuity, best corrected intermediate visual acuity, and the defocus curve were measured in both IOL groups. Results Group 1 comprised 36 eyes (18 patients) and Group 2, 40…

Malemedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresPseudophakiamedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignNear visual acuityFunctional LateralityNear acuityLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedLenses IntraocularDepth PerceptionVision BinocularPhacoemulsificationbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesIntermediate visual acuityOptometrySurgeryFemalemedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens

2007

To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismProsthesis DesignPupillaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineHumansDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryAccommodation OcularPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyHyperopiaOptometryFemaleSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct