Search results for "inocula"

showing 10 items of 206 documents

Poplar biomass production at phytomanagement sites is significantly enhanced by mycorrhizal inoculation

2017

Abstract Afforestation of trace element (TE)-contaminated soil, notably with fast growing trees producing large biomass has been demonstrated to be an attractive option for their bioremediation. Mycorrhizal fungi can form symbiotic associations with plants, contributing to TE tolerance and participating actively in bioremediation processes. We studied the effects of mycorrhizal inoculation on the growth of two poplar clones (Skado and I214), to large-scale. Two TE-contaminated sites of ca . 1 ha (Pierrelaye and Fresnes-sur-Escaut, France) were planted with 2200 trees, and were either inoculated with a mixed commercial inoculum or not-inoculated and allometric parameters were determined afte…

2. Zero hunger0106 biological sciences[SDV.EE]Life Sciences [q-bio]/Ecology environmentBioaugmentationInoculationfood and beveragesBiomassPlant Science15. Life on land010501 environmental sciencesContaminationBiology01 natural sciencesSoil contamination[ SDV.EE ] Life Sciences [q-bio]/Ecology environmentBioremediationSoil structureAgronomyAfforestationAgronomy and Crop ScienceEcology Evolution Behavior and SystematicsComputingMilieux_MISCELLANEOUS010606 plant biology & botany0105 earth and related environmental sciences
researchProduct

Effects of symmetry, texture, and monocular viewing on geographical slant estimation.

2018

Hills often appear to be steeper than they are. The unusual magnitude of this error has prompted extensive experimentation. The judgment mode, such as verbal vs. action-based measures, the state of the observer - whether exhausted or well rested - all can influence perceived geographical slant. We hold that slant perception is inherently shaky as soon as the slope in question is no longer palpable, that is if it is outside our personal space. To make this point, we have added symmetry, texture, and depression to the list of factors that might modulate slant perception. When the frontal slope of a hill is to be judged, it appears steeper when the side slopes are steep. We have used model hil…

AdultMaleAdolescentmedia_common.quotation_subjectExperimental and Cognitive PsychologyBridgemanStimulus (physiology)050105 experimental psychology03 medical and health sciencesJudgmentYoung Adult0302 clinical medicineArts and Humanities (miscellaneous)Personal spaceVision MonocularPerceptionDevelopmental and Educational PsychologyHumans0501 psychology and cognitive sciencesmedia_commonVision BinocularMonocularDepression05 social sciencesObserver (special relativity)Middle AgedStereopsisCase-Control StudiesSpace PerceptionVisual PerceptionFemalePsychology030217 neurology & neurosurgeryCognitive psychologyConsciousness and cognition
researchProduct

DaVinci's Mona Lisa entering the next dimension.

2013

For several of Leonardo da Vinci's paintings, such as The Virgin and Child with St Anne or the Mona Lisa, there exist copies produced by his own studio. In case of the Mona Lisa, a quite exceptional, rediscovered studio copy was presented to the public in 2012 by the Prado Museum in Madrid. Not only does it mirror its famous counterpart superficially; it also features the very same corrections to the lower layers, which indicates that da Vinci and the ‘copyist’ must have elaborated their panels simultaneously. On the basis of subjective (thirty-two participants estimated painter-model constellations) as well as objective data (analysis of trajectories between landmarks of both paintings), …

AdultMaleVision DisparityFamous Personsmedia_common.quotation_subjectArt historyExperimental and Cognitive PsychologyObjective dataYoung AdultOpticsArtificial IntelligenceHumansDimension (data warehouse)media_commonPaintingDepth Perceptionbusiness.industryMuseumsPerspective (graphical)ArtSensory SystemsOphthalmologyStereopsisHistory 16th CenturyBinocular disparityFemalePaintingsbusinessMona lisaStudioPerception
researchProduct

Monocular Versus Binocular Calibrations in Evaluating Fixation Disparity With a Video-Based Eye-Tracker

2015

When measuring fixation disparity (an oculomotor vergence error), the question arises as to whether a monocular or binocular calibration is more precise and physiologically more appropriate. In monocular calibrations, a single eye fixates on a calibration target that is taken as having been projected onto the center of the fovea; the corresponding vergence state represents the heterophoria (the resting vergence position), which has no effect on the calibration procedure. In binocular calibrations, a vergence error may be present and may affect the subsequent measurement of the fixation disparity during binocular recordings. This study includes a test of the precision of both monocular and …

AdultMaleVision Disparitygenetic structuresComputer scienceVideo RecordingExperimental and Cognitive PsychologyFixation OcularVergenceRetinaYoung AdultOpticsVision MonocularArtificial Intelligenceparasitic diseasesHumansComputer visionVision BinocularMonocularbusiness.industryVision DisparityConvergence Oculareye diseasesSensory SystemsStrabismusElectrooculographyOphthalmologyHeterophoriaCalibrationEye trackingBinocular disparityFemaleArtificial intelligenceFixation disparitybusinessBinocular visionPerception
researchProduct

Visual performance of two simultaneous vision multifocal contact lenses

2012

Purpose To evaluate and compare the visual performance of two simultaneous vision multifocal contact lenses (CLs). Methods In this cross-over study design 20 presbyopic subjects were fitted with two different simultaneous vision multifocal CLs (the PureVision Multifocal Low Add and Acuvue Oasys for Presbyopia) in random order. After 1 month, binocular distance visual acuity (BDVA) under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions, binocular near visual acuity (BNVA), binocular distance contrast sensitivity function (CSF) under photopic and mesopic conditions, binocular near CSF and defocus curve were measured. Subjects were then refitted with the alternative correction and the proc…

AdultMaleVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual Acuitylaw.inventionContrast SensitivitylawmedicineHumansContrast (vision)media_commonVision BinocularCross-Over Studiesbusiness.industryIntermediate distanceBoth lensesPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyOptometryFemalemedicine.symptombusinessOptometryPhotopic visionOphthalmic and Physiological Optics
researchProduct

Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.

2007

To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…

AdultMaleVisual acuitygenetic structuresPseudophakiaMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensContrast SensitivityLens Implantation IntraocularMedicineContrast (vision)HumansProspective Studiesmedia_commonAgedQuality Indicators Health CareAged 80 and overLenses IntraocularVision BinocularMonocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyQuality of visionOptometrySurgeryFemalesense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual function after implantation of a diffractive aspheric trifocal intraocular lens

2016

Purpose To evaluate distance, intermediate, and near vision after bilateral implantation of a diffractive aspheric trifocal intraocular lens (IOL). Methods This study enrolled 204 eyes of 102 patients who had bilateral implantation of the AT LISA tri 839MP IOL. Monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (4 meters), monocular and binocular uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) (30, 40 centimeters), binocular uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA) (50, 60, 70 centimeters), the defocus curve, and binocular photopic…

AdultMaleVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignRefraction OcularGlareContrast Sensitivity03 medical and health sciencesNear visionOcular physiology0302 clinical medicineLens Implantation IntraocularMedicineHumansProspective StudiesAgedLenses IntraocularVision BinocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationMiddle Agedeye diseasesOphthalmologyVisual function030221 ophthalmology & optometryOptometryFemalemedicine.symptombusinessBinocular vision030217 neurology & neurosurgeryPseudophakia
researchProduct

Fixation pattern analysis with microperimetry in nystagmus patients

2015

Objective: To assess the usefulness of microperimetry (MP) as an additional objective method for characterizing the fixation pattern in nystagmus. Design: Prospective study. Participants: Fifteen eyes of 8 subjects (age, 12–80 years) with nystagmus from the Lluís Alcanyís Foundation (University of Valencia, Spain) were included. Methods: All patients had a comprehensive ophthalmologic examination including a microperimetric examination (MAIA, CenterVue, Padova, Italy). The following microperimetric parameters were evaluated: average threshold (AT), macular integrity index (MI), fixating points within a circle of 1° (P1) and 2° of radius (P2), bivariate contour ellipse area (BCEA) considerin…

AdultMalemedicine.medical_specialtyVisual acuityAdolescentgenetic structuresFixation patternVisual AcuityPattern analysisNystagmusFixation OcularSensitivity and SpecificityNystagmus PathologicMicroperimetryNystagmusOphthalmologyMedicineHumansProspective StudiesChildAgedÓpticaAged 80 and overVision Binocularbusiness.industryObjective methodGeneral MedicineMiddle Agedeye diseasesSurgeryDominance OcularOphthalmologyOphthalmologic examinationFixation (visual)Visual Field TestsFemalemedicine.symptomVisual FieldsbusinessMicroperimetryBinocular vision
researchProduct

Subjective fixation disparity affected by dynamic asymmetry, resting vergence, and nonius bias.

2011

PURPOSE This study was undertaken to investigate how subjectively measured fixation disparity can be explained by (1) the convergent-divergent asymmetry of vergence dynamics (called dynamic asymmetry) for a disparity vergence step stimulus of 1° (60 arc min), (2) the dark vergence, and (3) the nonius bias. METHODS Fixation disparity, dark vergence, and nonius bias were measured subjectively using nonius lines. Dynamic vergence step responses (both convergent and divergent) were measured objectively. RESULTS In 20 subjects (mean age, 24.5 ± 4.3 years, visual acuity, ≥1.0; all emmetropic except for one with myopia, wearing contact lenses), multiple regression analyses showed that 39% of the v…

AdultMalemedicine.medical_specialtyVisual acuityVision Disparitygenetic structuresAdolescentEye Movementsmedia_common.quotation_subjectRestVisual AcuityEmmetropiaAudiologyAsymmetrylaw.inventionFeedbackYoung Adultlawparasitic diseasesmedicineHumansmedia_commonVision BinocularVision TestsVision DisparityMean ageNoniusConvergent and divergent productionFemalemedicine.symptomFixation disparityPsychologyInvestigative ophthalmologyvisual science
researchProduct

Vision evaluation in people with Down's syndrome.

1994

We tested the colour vision of 72 people with Down's syndrome using the Ishihara test and an anomaloscope. We found that 13 of the subjects, 6 males and 7 females, had defective colour vision according to Pickford's classification. In monocular vision 10 eyes were protan (five simple, three extreme and two deviant), one eye was simple deuteranomalous and the remaining eyes were normal: in binocular vision four of the subjects were protan (two simple and two deviant), two subjects were deutan (one simple and one deviant) and the rest were normal. Many of our subjects had lens opacities, strabismus, nystagmus, hypermetropia, high myopia and astigmatism, confirming literature reports. The cont…

AdultMalemedicine.medical_specialtygenetic structuresAdolescentColor visionColor Vision DefectsNystagmusAstigmatismAudiologyCataractNystagmus PathologicDevelopmental psychologyVision disorderContrast SensitivityVision MonocularmedicineHumansStrabismusChildVision Binocularmedicine.diseaseRefractive Errorseye diseasesSensory SystemsAnomaloscopeStrabismusOphthalmologyFemalemedicine.symptomDown SyndromePsychologyBinocular visionMonocular visionOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct