An integrated calibration system for liquid argon calorimetry

1999

Abstract A novel technical solution for an integrated version of the pulse generator of a calibration system for liquid argon calorimeters is presented. It consists of a differential amplifier with automatic offset compensation, a current mirror and a switching logic. These components are integrated on an ASIC chip in CMOS technology. The technical realisation as well as results on the performance are presented.

PhysicsNuclear and High Energy PhysicsOffset (computer science)Physics::Instrumentation and DetectorsPulse generatorAmplifierDifferential amplifierCalorimetryComputer Science::Hardware ArchitectureCurrent mirrorApplication-specific integrated circuitCMOSHardware_INTEGRATEDCIRCUITSElectronic engineeringInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Position sensitive scintillator based detector improvements by means of an integrated front-end

2009

PESIC is an integrated front-end for multianode photomultiplier based nuclear imaging devices. Its architecture has been designed to improve position sensitive detectors behavior by equalizing its response over its whole area. Its preamplying stage introduces two main benefits: digitally programmable gain adjustment for every photomultiplier output, and isolation from other front-end electronics by means of current buffers. This last feature allows to use different types of photomultipliers and optimizes front-end deadtime, reducing impact position dependent output delay. PESIC also includes an indirect measurement of the depth of interaction of the gamma ray inside the scintillator crystal…

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryDetectorEqualization (audio)ScintillatorFront and back endsOpticsApplication-specific integrated circuitCalibrationElectronicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The X-ray imager on AXO

2001

Abstract DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and …

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and Detectorsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaDetectorAstrophysics::Instrumentation and Methods for AstrophysicsX-ray detectorSpace explorationOpticsApplication-specific integrated circuitObservatorySatelliteElectronicsbusinessInstrumentationEnergy (signal processing)
researchProduct

A coded mask for γ-ray astronomy. Design and calibration

2003

Abstract The high-resolution γ-ray spectrometer (SPI) is one of the two main instruments on board the ESA INTEGRAL satellite successfully launched in October 2002. SPI uses coded aperture mask technique in order to have imaging capabilities at the energy band (20 keV–8 MeV) it will study celestial sources. The SPI imaging performance depends critically on the quality of the coded mask response and also on the precise knowledge of such response function. In this paper we present a general description of the SPI Coded Mask design together with its main features. Scientific impact of INTEGRAL SPI Coded Mask design on the instrument capabilities is also discussed. Results obtained for Mask cali…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaAstrophysics::Instrumentation and Methods for AstrophysicsIntegrated circuit layoutOn boardOpticsQuality (physics)CalibrationSatelliteCoded aperturebusinessInstrumentationRemote sensingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Frontend electronics for high-precision single photo-electron timing using FPGA-TDCs

2014

Abstract The next generation of high-luminosity experiments requires excellent particle identification detectors which calls for Imaging Cherenkov counters with fast electronics to cope with the expected hit rates. A Barrel DIRC will be used in the central region of the Target Spectrometer of the planned PANDA experiment at FAIR. A single photo-electron timing resolution of better than 100 ps is required by the Barrel DIRC to disentangle the complicated patterns created on the image plane. R&D studies have been performed to provide a design based on the TRB3 readout using FPGA-TDCs with a precision better than 20 ps RMS and custom frontend electronics with high-bandwidth pre-amplifiers and …

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryDetectorIntegrated circuitImage planelaw.inventionTime-to-digital converterApplication-specific integrated circuitlawElectronicsField-programmable gate arraybusinessInstrumentationComputer hardwareNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Detector blockbased on arrays of 144 SiPMs and monolithic scintillators: A performane study

2015

[EN] We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12 12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured. & 2014 Elsevier B.V. All…

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyPhotonPhysics::Instrumentation and Detectorsbusiness.industryASICDetectorSilicon photomultipliersScintillatorScintillator crystalFull width at half maximumSilicon photomultiplierApplication-specific integrated circuitmedicineOptoelectronicsMedical physicsbusinessMATEMATICA APLICADAInstrumentationImage resolutionPositron Emission TomographyBlock (data storage)
researchProduct

The CZT X-ray imager on AXO

2001

DSRI has initiated a development program of CZT X-ray and gamma ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: The X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated …

PhysicsPhysics::Instrumentation and Detectorsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaDetectorAstrophysics::Instrumentation and Methods for AstrophysicsModular designSpace explorationOpticsApplication-specific integrated circuitObservatoryLow-power electronicsSatellitebusinessEnergy (signal processing)
researchProduct

Experimental demonstration of Bloch mode parity change in photonic crystal waveguide

2004

We experimentally show coupling between two photonic crystal waveguide Bloch modes having a different parity. A monomode ridge waveguide etched in a silicon-on-insulator substrate and connecting to the photonic crystal waveguide allows us to excite the even Bloch mode. Transmission measurements, performed on a broad spectral range, show the even mode propagation along the defect line. Then, spectrally resolved near-field patterns obtained by using a scanning near-field optical microscope in collection mode for wavelengths, inside and outside the multimode region of the photonic crystal waveguide, clearly demonstrate coupling phenomenon between even and odd modes.

Physics[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]Multi-mode optical fiber[ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]Physics and Astronomy (miscellaneous)Guided-mode resonancebusiness.industryPhotonic integrated circuitPhysics::Optics02 engineering and technologyMicrostructured optical fiber021001 nanoscience & nanotechnology01 natural sciencesYablonoviteOptics0103 physical sciencesOptoelectronicsNear-field scanning optical microscopeRadiation mode010306 general physics0210 nano-technologybusinessComputingMilieux_MISCELLANEOUSPhotonic crystal
researchProduct

Evaluation of performance of a hybrid electro-optic directional coupler and a Mach–Zehnder switch

2017

The efficiency of an electro-optic (EO) directional coupler (DC) and a Mach–Zehnder (MZ) switch is discussed. The specific designs employ a passive waveguide core and an EO cladding. The performance of a DC switch was evaluated by numerical methods, namely coupled mode theory (CMT), eigenmode expansion (EME) method, and beam envelope method. Using the CMT and EME methods, it is shown that in the DC with a passive waveguide core and EO cladding at certain waveguide parameters the switching effect does not take place. The effect is demonstrated for the first time and suggests that careful optimization of the DC switch should be done before experimental realization of the device. The efficienc…

Physicsbusiness.industryPhotonic integrated circuitEigenmode expansion02 engineering and technologyCondensed Matter PhysicsCladding (fiber optics)Mach–Zehnder interferometerCoupled mode theory01 natural sciencesElectronic Optical and Magnetic Materialslaw.invention010309 optics020210 optoelectronics & photonicsOpticslaw0103 physical sciences0202 electrical engineering electronic engineering information engineeringPower dividers and directional couplersHybrid couplerbusinessWaveguideJournal of Nanophotonics
researchProduct

Synchronized photonic modulators driven by surface acoustic waves

2013

Photonic modulators are one of the most important elements of integrated photonics. We have designed, fabricated, and characterized a tunable photonic modulator consisting of two 180 degrees-dephased output waveguide channels, driven by a surface acoustic wave in the GHz frequency range built on (Al,Ga)As. Odd multiples of the fundamental driven frequency are enabled by adjusting the applied acoustic power. A good agreement between theory and experimental results is achieved. The device can be used as a building block for more complex integrated functionalities and can be implemented in several material platforms. (C) 2013 Optical Society of America

Physicsbusiness.industrySurface acoustic wavePhotonic integrated circuitPhysics::OpticsIntegrated optics devicesAcoustic waveModulatorsSound powerAtomic and Molecular Physics and Opticslaw.inventionÒptica Aparells i instrumentsTECNOLOGIA ELECTRONICAOpticsAcousto-optical deviceslawSurface waveTEORIA DE LA SEÑAL Y COMUNICACIONESOptoelectronicsPhotonicsbusinessWaveguideBlock (data storage)
researchProduct