Search results for "intensity"
showing 10 items of 1091 documents
Reduced intensity conditioning HLA identical sibling donor allogeneic stem cell transplantation for patients with follicular lymphoma: long-term foll…
2010
Background Allogeneic hematopoietic stem cell transplantation is an effective treatment for patients with poor risk lymphoma, at least in part because of the graft-versus-lymphoma effect. Over the past decade, reduced intensity conditioning regimens have been shown to offer results similar to those of conventional high-dose conditioning regimens but with lower toxicity early after transplantation, especially in patients with chemosensitive disease at transplant. Design and Methods The aim of this study was to analyze the long-term outcome of patients with follicular lymphoma who received an HLA identical sibling allogeneic stem cell transplant with a reduced intensity conditioning regimen w…
Fatigue and Recovery After High-Intensity Exercise Part II: Recovery Interventions
2004
The purpose of this study was to determine the effect of three types of recovery intervention to neuromuscular function after high-intensity uphill running exercise. The 20-min recovery interventions were (i) passive, (ii) active (running at 50 % of maximal aerobic speed), and (iii) low-frequency electromyostimulation. Evoked twitch and maximal voluntary contractions of knee extensor muscles (KE) and EMG of the vastus lateralis and vastus medialis were analysed immediately after the exercise, 10 min after the end of the recovery periods, and 65 min after the exercise (Post65). An all-out running test was also performed 80 min after the end of the fatiguing exercise. No significant differenc…
Neuromuscular fatigue following high versus low-intensity eccentric exercise of biceps brachii muscle
2009
International audience; Purpose: This study investigated neuromuscular fatigue following high versus low-intensity eccentric exercise corresponding to the same amount of work.Methods: Ten volunteers performed two eccentric exercises of the elbow flexors: a high-intensity versus a low-intensity exercise. Maximal voluntary contraction torque and surface electromyography of the biceps brachii muscle were recorded before, immediately and 48 h after exercises. Maximal voluntary activation level, neural (M-wave) and contractile (muscular twitch) properties of the biceps brachii muscle were analysed using electrical stimulation techniques.Results: Maximal voluntary contraction torque was significa…
Bench Press and Push-up at Comparable Levels of Muscle Activity Results in Similar Strength Gains
2014
Electromyography (EMG) exercise evaluation is commonly used to measure the intensity of muscle contraction. Although researchers assume that biomechanically comparable resistance exercises with similar high EMG levels will produce similar strength gains over the long term, no studies have actually corroborated this hypothesis. This study evaluated EMG levels during 6 repetition maximum (6RM) bench press and push-up, and subsequently performed a 5-week training period where subjects were randomly divided into 3 groups (i.e., 6RM bench press group, 6RM elastic band push-up group, or control group) to evaluate muscle strength gains. Thirty university students with advanced resistance training …
Effects of a Short-Term Aquatic Resistance Program on Strength and Body Composition in Fit Young Men
2009
This study was designed to analyze the effects of a short-term periodized aquatic resistance program (PARP) on upper-limb maximum strength, leg muscular power, and body composition (BC) in fit young men. Twenty subjects (21.2 +- 1.17 years) were randomly assigned to an exercise or control group; 12 subjects completed the study. The aquatic exercise group (AEG; n = 7) participated in an 8-week supervised program of 3 d.wk-1, and the control group (CG; n = 5) maintained their regular activities. The PARP consisted of a total-body resistance exercise workout using aquatic devices that increased drag force, with a cadence of movement controlled and adjusted individually for each exercise and su…
A method for monitoring intensity during aquatic resistance exercises.
2008
The aims of this study were (i) to check whether monitoring of both the rhythm of execution and the perceived effort is a valid tool for reproducing the same intensity of effort in different sets of the same aquatic resistance exercise (ARE) and (ii) to assess whether this method allows the ARE to be put at the same intensity level as its equivalent carried out on dry land. Four healthy trained young men performed horizontal shoulder abduction and adduction (HSAb/Ad) movements in water and on dry land. Muscle activation was recorded using surface electromyography of 1 stabilizer and several agonist muscles. Before the final tests, the ARE movement cadence was established individually follow…
Intraoperative imaging findings in transcranial MR imaging-guided focused ultrasound treatment at 1.5T may accurately detect typical lesional finding…
2020
To assess the intraoperative neuroimaging findings in patients treated with transcranial MR-guided focused ultrasound (tcMRgFUS) thalamotomy using 1.5T equipment in comparison with the 48-h follow-up.Fifty prospectively enrolled patients undergoing unilateral tcMRgFUS thalamotomy for either medication-refractory essential tremor (n = 39) or Parkinson tremor (n = 11) were included. Two radiologists evaluated the presence and size of concentric lesional zones (zone I, zone II, and zone III) on 2D T2-weighted sequences acquired intraoperatively after the last high-energy sonication and at 48 h. Sonication parameters including number of sonications, delivered energy, and treatment temperatures …
Real-time control for transscleral cyclophotocoagulation.
1998
• Background: In transscleral cyclophotocoagulation, the surgeon cannot directly observe the applied laser effects. Overdosage, possibly resulting in unwanted pop effects, or underdosage with no therapeutic effect therefore often occur. • Method and materials: Laser radiation passing through the sclera and ciliary body is partly reflected from the fundus and can be monitored from outside the eye by a detector system. Since all other parameters influencing the intensity of the recorded radiation are constant in time during one laser exposure, the time dependence of this radiation directly reflects the change of transmission of the treated tissue. The laser exposure therefore can be stopped b…
Exercise intensity progression for exercises performed on unstable and stable platforms based on ankle muscle activation.
2013
Ankle sprains are a common sports injury. The literature focuses on the application of neuromuscular training for the improvement of balance, injury prevention and rehabilitation. However, there is a dearth of knowledge about the appropriate prescription of exercises using unstable platforms and surfaces. The purpose of this study was to devise an ankle rehabilitation or training program with exercise progression based on the extent of muscle activation, employing platforms with different levels of stability and additional resistance. A descriptive study of electromyography (EMG) during ankle exercises was performed with a convenience sample of healthy subjects. Forty-four subjects complete…
Muscle activity levels in upper-body push exercises with different loads and stability conditions.
2014
Exercises that aim to stimulate muscular hypertrophy and increase neural drive to the muscle fibers should be used during rehabilitation. Thus, it is of interest to identify optimal exercises that efficiently achieve high muscle activation levels.The purpose of this study was to compare the muscle activation levels during push-up variations (ie, suspended push-ups with/without visual input on different suspension systems, and push-ups on the floor with/without additional elastic resistance) with the bench press exercise and the standing cable press exercise both performed at 50%, 70%, and 85% of the 1-repetition maximum.Young fit male university students (N = 29) performed 3 repetitions in …