Search results for "interventional"
showing 10 items of 300 documents
Retroaortic left renal vein joining the left common iliac vein
2000
Retroaortic left renal vein joining the left common iliac vein is a rare congenital anomaly in the development of the inferior vena cava. To our knowledge, only one case has been reported in the literature; however, its imaging features have never been described. A 27-year-old male presented with a 1-year history of recurrent right flank pain, dysuria, hematuria, and fever (39 degrees C). Computed tomography and MR venography showed a retroaortic left renal vein joining the left common iliac vein. We present the CT and MR venography findings and discuss their feasibility in showing this congenital anomaly.
Prevalence and characteristics of coronary artery disease in a population with suspected ischaemic heart disease using CT coronary angiography: corre…
2008
Purpose. This study was undertaken to describe the correlation between the distribution of coronary artery disease (CAD) in a symptomatic population with suspected ischaemic heart disease, cardiovascular risk factors (RF) and clinical presentation. Materials and methods. We studied 163 patients (mean age 65.5 years; 101 men and 62 women) referred for multidetector computed tomography coronary angiography (MDCT-CA) to rule out CAD. The patients had no prior history of revascularisation or myocardial infarction. We analysed how the characteristics of CAD (severity and type of plaque) can change with the increase in RF and how they are related to different clinical presentations. Results. Pati…
Benign focal liver lesions: spectrum of findings on SonoVue-enhanced pulse-inversion ultrasonography.
2005
The prevalence of benign focal liver lesions (BFLL) is high both in the general population and in patients with known malignancies. The gray-scale ultrasound (US) technique is usually the first-line imaging modality used in the radiological workup of such lesions, but unfortunately it lacks specificity. Furthermore, Doppler examination may often be unsatisfactory owing to motion artefacts, or when small or deeply located lesions are evaluated. Recently, microbubble-based contrast agents used in combination with gray-scale US techniques, which are very sensitive to nonlinear behavior of microbubbles, have led to a better depiction of both microvasculature and macrovasculature of focal hepati…
Mid-term results of zone 0 thoracic endovascular aneurysm repair after ascending aorta wrapping and supra-aortic debranching in high-risk patients
2017
Objectives Surgical repair of aneurysmal disease involving the ascending aorta, aortic arch and eventually the descending aorta is generally associated with significant morbidity and mortality. A less invasive approach with the ascending wrapping technique (WT), supra-aortic vessel debranching (SADB) and thoracic endovascular aneurysm repair (TEVAR) in zone 0 was developed to reduce the associated risk in these patients. Methods During a 10-year period, consecutive patients treated by the ascending WT, SADB and TEVAR in zone 0 were included. All patients were considered at high risk for conventional surgery. Measured outcomes included perioperative deaths and morbidity, maximal aortic trans…
Necessary Catheter Diameters for Mechanical Thrombectomy with ADAPT
2017
BACKGROUND AND PURPOSE: Large-bore catheters allow mechanical thrombectomy in ischemic stroke by engaging and retrieving clots without additional devices (direct aspiration first-pass technique [ADAPT]). The purpose of this study was to establish a model for minimal catheter diameters needed for ADAPT. MATERIALS AND METHODS: We established a theoretic model for the calculation of minimal catheter diameters needed for ADAPT. We then verified its validity in 28 ADAPT maneuvers in a porcine in vivo model. To account for different mechanical thrombectomy techniques, we factored in ADAPT with/without a hypothetic 0.021-inch microcatheter or 0.014-inch microwire inside the lumen of the aspiration…
Benchmarking Wilms’ tumor in multisequence MRI data: why does current clinical practice fail? Which popular segmentation algorithms perform well?
2019
Wilms' tumor is one of the most frequent malignant solid tumors in childhood. Accurate segmentation of tumor tissue is a key step during therapy and treatment planning. Since it is difficult to obtain a comprehensive set of tumor data of children, there is no benchmark so far allowing evaluation of the quality of human or computer-based segmentations. The contributions in our paper are threefold: (i) we present the first heterogeneous Wilms' tumor benchmark data set. It contains multisequence MRI data sets before and after chemotherapy, along with ground truth annotation, approximated based on the consensus of five human experts. (ii) We analyze human expert annotations and interrater varia…
Ultrasound-guided musculoskeletal interventional procedures around the shoulder
2021
Ultrasound is a fast, accessible, reliable, and radiation-free imaging modality routinely used to assess the soft tissues around the shoulder. It enables to identify a wide range of pathological conditions. Furthermore, most ultrasound-guided musculoskeletal interventional procedures around the shoulder produce better results in terms of accuracy and clinical efficacy than those performed in a blinded fashion. Indeed, intra-articular and peri-articular interventional procedures can be easily performed under continuous ultrasound monitoring to ensure the correct position of the needle and to deliver the medication to a specific target. Several technical approaches and medications can be used…
Importance of calibration for diameter and area determination by intravascular ultrasound
1996
Intravascular ultrasound (IVUS) permits quantitative assessment of the lumen diameter and area of coronary arteries. The experimental study was performed to evaluate the accuracy of diameter and area measurements.Lumen quantitation (lumen diameter D and cross-sectional area A) in lucite tubes (lumen diameter 2.5 to 5.7 mm, Plexiglas) was performed using a mechanical IVUS system (HP console, 3.5 F catheter, Boston Scientific, 30 MHz). The influence of fluid type (blood, water and saline solution), fluid temperature (20 degrees C/37 degrees C), catheter to catheter variation, gain setting and ultrasound frequency (12, 20 and 30 MHz) was determined. In blood at 20 degrees C there was a constan…
German Survey on EUS-Guided Diagnosis and Management of Gastrointestinal Stromal Tumors (GISTs) - Evidence or "Gut-Feeling"?
2015
To examine practice patterns of endosonographers in diagnosing and managing gastrointestinal stromal tumors (GISTs) in Germany.A modified published survey (Ha et al., Gastrointest Endosc 2009) was sent to endosonographic ultrasound (EUS) customers in Germany. The survey was also publicized on the homepage of an EUS interest group. To avoid duplicate opinions, participants were asked to return one survey per institution.142 centers of roughly 850 German EUS centers responded. 25 % were from University hospitals and 74 % from community hospitals. 61 % performed 2 EUS scans for suspected subepithelial lesions/week. Although 97 % of respondents believed that tissue acquisition with CD117 immuno…
Imaging of inner ear malformations: a primer for radiologists
2021
AbstractIn the multidisciplinary management of patients with inner ear malformations (IEMs), the correct diagnosis makes the differences in terms of clinical and surgical treatment. The complex anatomical landscape of the inner ear, comprising several small structures, makes imaging of this region particularly challenging for general radiologists. Imaging techniques are important for identifying the presence and defining the type of IEM and the cochlear nerve condition. High-resolution magnetic resonance imaging (MRI) sequences and high-resolution computed tomography (HRCT) are the mainstay imaging techniques in this area. Dedicated MRI and HRCT protocols play an important role in the diagn…