Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable.
2016
OBJECTIVES: Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS: Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The …
TAVI imaging: over the echocardiography
2020
Aortic valve stenosis (AS) is a common valvular heart disease. Recently, transcatheter aortic valve implantation (TAVI) has changed the treatment of severe AS in elderly patients with contraindications to traditional surgical replacement. Echocardiography is conventionally used as the first imaging modality to assess the presence and severity of AS and to provide anatomical and functional information. Nowadays, imaging techniques play a crucial role in the planning of TAVI to define suitable candidates. Computed tomography (CT) is essential to display the anatomy of the aortic valve complex (including aortic annulus, Valsalva sinuses, coronary arteries ostia, sinotubular junction), thoracoa…
Imaging in the catheterization laboratory
1993
Recent work confirms that visual assessment of the effect of widely employed coronary interventions is highly inaccurate. Rapid and reliable on-line angiographic quantitation is a useful advance, but problems in the application of the technique are encountered in a substantial number of cases. New algorithms have been devised to provide a comprehensive assessment of the geometry and likely functional significance of lesions as well as an objective evaluation of lesion morphology, and recent work has provided the framework for the quantitation of diffuse disease. Studies with intravascular ultrasound confirm the inadequate sensitivity of angiography in demonstrating mild to moderate atheroma…
Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium
2021
Abstract Background There is a paucity of randomized data regarding the safety and efficacy of the use of intracardiac echocardiography (ICE) from the left atrium (LA) to guide left atrial appendage occlusion (LAAO) procedures under local anesthesia using either of the available devices. Hypothesis The aim of this study was to compare the efficacy and safety of ICE from the LA with transesophageal echocardiography (TEE) for guidance during transcatheter LAAO procedures. Methods Single‐center, cohort study of patients undergoing LAAO with the Amplatzer Cardiac Plug or Watchman device. Procedures were guided by ICE from the LA with local anesthesia (n = 175) or TEE under general anesthesia (n…
Integrated non-invasive approach to atherosclerosis with cardiac CT and carotid ultrasound in patients with suspected coronary artery disease
2017
The aim of the study was to compare the atherosclerotic disease in the coronary and carotid arteries in patients who underwent non-invasive imaging for suspected stable coronary artery disease (CAD). 107 patients (64 men, age 59 ± 12) with atypical chest pain underwent cardiac CT (CCT) and carotid ultrasound (US) on the same day. Severity (obstructive or not-obstructive disease), location, shape, and composition of atherosclerotic plaques in the two districts were evaluated. Patients presented normal coronary arteries in 36 % (n = 38), not-obstructive CAD in 36 % (n = 39), and obstructive CAD in 28 % (n = 30), while had normal carotid arteries in 53 % (n = 57), not-obstructive disease in 44…
Umbilical venous catheters placement evaluation on frontal radiogram: application of a simplified flow-chart for radiology residents
2017
Background: Umbilical Venous Catheter (UVC) are commonly used in neonatal period; they can be not correctly positioned and could be associated with complications. The purpose of this article is to suggest a flow-chart to evaluate the placement of UVC, testing it in young radiologists-in-training. Method: We developed a simple flow-chart to asses, steps by step, UVC placement considering its course and tip location (ideally placed in the atriocaval junction). We tested the flow-chart impact asking to 20 residents to evaluate the placement of 10 UVC before and after they familiarized with the flow-chart and the anatomical findings of a newborn. The agreement among the 20 students was evaluate…
Necessary Catheter Diameters for Mechanical Thrombectomy with ADAPT
2017
BACKGROUND AND PURPOSE: Large-bore catheters allow mechanical thrombectomy in ischemic stroke by engaging and retrieving clots without additional devices (direct aspiration first-pass technique [ADAPT]). The purpose of this study was to establish a model for minimal catheter diameters needed for ADAPT. MATERIALS AND METHODS: We established a theoretic model for the calculation of minimal catheter diameters needed for ADAPT. We then verified its validity in 28 ADAPT maneuvers in a porcine in vivo model. To account for different mechanical thrombectomy techniques, we factored in ADAPT with/without a hypothetic 0.021-inch microcatheter or 0.014-inch microwire inside the lumen of the aspiration…
Under Pressure: Comparison of Aspiration Techniques for Endovascular Mechanical Thrombectomy.
2018
BACKGROUND AND PURPOSE: Blood flow should be interrupted during mechanical thrombectomy to prevent embolization of clot fragments. The purpose of our study was to provide a handy overview of the most common aspiration devices and to quantify their flow characteristics. MATERIALS AND METHODS: We assessed volumetric flow rates generated by a 60-mL VacLok vacuum pressure syringe, a Pump MAX aspiration pump, and a Dominant Flex suction pump connected to the following: 1) an 8F long sheath, 2) an 8F balloon-guide catheter, 3) an ACE 64 distal aspiration catheter, and 4) an AXS Catalyst 6 Distal Access Catheter. We used a water/glycerol solution, which was kept at a constant temperature of 20°C (…
Darstellung des Blutflusses in den Gebärmutterarterien und im normalen sowie malignen Gebärmuttergewebe mittels einer 2D-Multiphasen-Tagging-Technik
1998
PURPOSE The aim of this pilot study was to evaluate a 2D-STAR technique as a non contrast-enhanced approach to demonstrate the uterine artery and its branches and to assess the cervical uterine blood flow in healthy volunteers and in patients with advanced uterine cervical carcinoma. MATERIALS AND METHODS Seven healthy volunteers (mean age, 29 years) and twenty-two patients (mean age, 52 years) with advanced cancer of the uterine cervix (FIGO IIB-IVA) were prospectively examined by 2D-STAR imaging at different inversion delay times (300 ms-1900 ms) which showed the passage of a blood bolus through normal and malignant tissue of the uterine cervix. RESULTS The uterine artery was well visuali…
Appropriateness criteria for the use of cardiac computed tomography, SIC-SIRM part 2: Acute chest pain evaluation; Stent and coronary artery bypass g…
2022
In the past 20 years, cardiac computed tomography (CCT) has become a pivotal technique for the noninvasive diagnostic workup of coronary and cardiac diseases. Continuous technical and methodological improvements, combined with fast growing scientific evidence, have progressively expanded the clinical role of CCT. Randomized clinical trials documented the value of CCT in increasing the cost-effectiveness of the management of patients with acute chest pain presenting in the emergency department, also during the pandemic. Beyond the evaluation of stents and surgical graft patency, the anatomical and functional coronary imaging have the potential to guide treatment decision-making and planning …