Componenti di un impianto fotovoltaico
2013
Experimental Validation of Maximum Constant Boost Control and Switching Frequency Optimal for three-phase Quasi-Z-Source Converters
2020
This paper presents a modified modulation scheme for quasi-Z-Source converters, based on the Maximum Constant Boost Control (MCBC) concept and Switching Frequency Optimal (SFO) as reference signal. The effectiveness of the proposed technique is validated by comparing the obtained results (in terms of AC harmonic content and voltage stress) with those carried out from traditional modulation schemes. For this reason, a test bench has been assembled and the benefits of the SFO MCBC modulation scheme have been valuated.
Investigation and reduction of losses on inverter-fed induction motors
2017
An electric motor is more effective and flexible when supplied by a frequency converter. The frequency converter not only produces the fundamental voltage but also a set of higher harmonics which cause additional losses in the motor. Losses in the frequency converter are normally neglected in the drive dimensioning due to insufficient data available from manufacturers. Motor's losses can be reduced by increasing the switching frequency of frequency converters. An increase of the switching frequency may result in higher losses in the frequency converter. This work investigates analytically and experimentally the dependence of the losses of modern motor and frequency converter on a switching …
Robust model-following control of parallel UPS single-phase inverters
2008
This paper presents a robust control technique applied to modular uninterruptible power-supply (UPS) inverters operating in parallel. When compared to conventional proportional-integral (PI) control, the proposed technique improves the response of the output voltage to load steps and to high distorted output currents, reducing the distortion of the output voltage. Furthermore, an excellent distribution of currents between modules is achieved, resulting in fine power equalization between the inverters on stream. The crossover frequency of the different loop gains involved is moderate, so that robustness to variations of the operation point and to modeling uncertainties is achieved. A compara…
DC link voltage swinging and load current unbalance in fault tolerant VSI. overview and compensation strategies
2015
The topic of this paper is the discussion on the performance of a three-phase fault tolerant inverter with particular attention to the underrated aspect of current unbalances occurring due to the DC link voltage fluctuates after the inverter reconfiguration. Capacitor voltage unbalance affects not only the average output voltage of the inverter, but also its performance. In fact, the inverter performance depends on the fluctuating DC-link voltage components rather than on the average DC-link voltage. After a brief analysis of the voltage fluctuation phenomena resulting from fault tolerant configuration and their effect on load current unbalance, the Authors consider different compensating p…
Numerical Analysis of Medium Scale PV Plants and Their Power-Flow Control System With a Simple Three Phase Inverter
2012
This paper presents a mathematical analysis of a medium scale Photovoltaic (PV) power generation system connected to the distribution network and of its control system, in which the conversion stage is unique thanks to the absence of a boost chopper. Boost choppers are usually used as actuator for maximum power point tracking (MPPT). The conducted analysis leads to the conclusion that the used inverter presents two degrees of freedom that can be easily exploited in a control system in which the inverter simultaneously realizes the interconnection to the grid and at the same time realizes the MPPT control. The structure of the control system is then presented, discussed and then validated by…
Design and simulation of a fast DC recharging station for EV
2017
In this paper a detailed description of the design and simulation of a DC ultra-fast recharging station for Electric Vehicles is carried out. The system consist of a single AC/DC grid connected inverter, a DC-Bus and two DC/DC converter to recharge the batteries of the EVs. The system also has the vehicleto- grid (V2G) capability. The design of the components of the system and the control schemes are explained and a simulation of the system, performed in Matlab/Simulink environment is presented.
Grid-Following and Grid-Forming MODELS in ATP-EMTP for Power Systems Simulation
2022
The paper presents the models of grid-following and grid-forming converters in the software ATP-EMTP for power systems simulation. The models are developed using the MODELS language, they are described in details discussing all issues and aspects related to the implementation, and they are also shared as open source models. The models are validated with a simulation-based approach, comparing the results with the models developed in MATLAB/Simulink and in NEPLAN, considering both the phasor RMS and EMT time domains, and thus performing a comprehensive cross-platform and cross-domain validation. In line with the spirit of the ATP software and community, the models of grid-following and grid-f…
Electrostatic synchronous generator model of an Inverter-Based Distributed Generators
2015
In this paper, the idea of modelling the Inverter-Based Distributed Generators by using the concept of Electrostatic synchronous machines is discussed. A mathematical model of the inverter has been established which depends on the dc bus voltage, modulation index and frequency of the system. Two mathematical models have been developed: a small signal model and a steady-state model. These mathematical models will be helpful in studying the stability of a microgrid; especially when studying the transient stability performance of on-grid operation of converter-based distributed generator with multi-machine microgrid. Simulation results using Matlab/Simulink are carried out.
Current fault signatures of Voltage Source Inverters in different reference frames
2016
This paper considers different current patterns used to identify the correct fault signatures in Voltage Source Inverters (VSI). At the beginning, the Authors consider the currents patterns from which a simple or a double fault can be encompassed both in the case of controllable device only or with its free wheeling companion diode. After the discussion of diagnosis algorithm suitable for electrical drives and principally based on a persistent near zero current condition current in the natural phase reference frame, the stationary reference frame is then considered as a tool to identify both the faulted phase as the device or various combination of faulted devices. On the contrary, the Auth…