A 9-level three-phase multilevel converter with harmonic mitigation and integrated battery balancing
2019
In this paper, a 9 level three-phase multilevel converter with a harmonic mitigation control method and an integrated battery balancing algorithm for automotive purpose is proposed. Each level of the converter is composed by a buck-boost converter and an h-bridge in cascaded connection. The control algorithm is implemented to achieve the harmonic mitigation on the output voltage waveform and to maintain the battery input voltages balanced. The design and operation of the system is described, and simulation study is reported using Matlab/Simulink platform.
Performance Evaluation of a Three- Phase Five-Level Quasi-Z-Source Cascaded H-Bridge for Grid-Connected Applications
2018
In the field of the PV generation, Quasi-Z-source cascaded H-bridge (qZS-CHB) inverters are promising due to their features of modularity and high voltage conversion ratio. Thus, new topology structures and innovative modulation techniques are continuously being developed to improve the performance in terms of voltage stress and harmonic content. This paper proposes an innovative modulation technique that allows reducing the voltage stress and a specially designed grid-connected control strategy is also introduced. Through simulations in MATLAB, it has been validated that the performance of a three-phase five-level qZS-CHB is improved with the proposed solution.
A Novel Symmetrical Boost Modulation Method for qZS-based CHB Inverters
2020
Quasi-Z-source cascaded H-bridge (qZS-CHB) inverters are arising as an innovation in the field of the electrical conversion for PV applications. This type of converters inherit the advantages of multilevel inverters and single-stage configuration. In this context, this paper proposes a novel symmetrical boost modulation strategy for qZS CHB multilevel inverters to increase the performance in terms of voltage stresses and power quality. The novelty lies in the adoption of a different concept to generate the shoot-through states compared to the traditional methods. Simulation analysis in a grid connected application to evaluate the benefits of this boost method is performed in the MATLAB/PLEC…
Modified Modulation Techniques for Quasi-Z-Source Cascaded H-Bridge Inverters
2018
Quasi-Z-source cascaded H-bridge (q Z S - C H B) inverters are one promising solution for high power photovoltaic (PV) systems. This type of topologies inherits the advantages of cascaded converters (i.e., multilevel outputs) and impedance-source inverters (i.e., high conversion ratios). In addition, it allows increasing the inverter reliability (with high redundancy). However, the modulation and control of qZS-CHB inverters are challenging to a certain extent. Thus, this paper proposes modified modulation techniques to increase the performances of qZS-CHB converters in terms of voltage gains and stresses. The novelty lies in the use of the switching frequency optimal as reference signals i…
Experimental study on B-spline-based modulation schemes applied in multilevel inverters for electric drive applications
2019
This work presents the design, simulation, and experimental validation of new B-Spline-based modulation techniques applied to a Multilevel Power Inverter (MPI), particularly focusing the attention on the harmonic content of the output voltages of the inverter. Simulation and experimental results are proposed and discussed, mainly describing the potential benefits, such as the increase of the multi-level operation of the converter, and drawbacks (low-order harmonics) related to the adoption of B-Spline functions for multilevel inverters applied in the field of electrical drives.
Robust model-following control of parallel UPS single-phase inverters
2008
This paper presents a robust control technique applied to modular uninterruptible power-supply (UPS) inverters operating in parallel. When compared to conventional proportional-integral (PI) control, the proposed technique improves the response of the output voltage to load steps and to high distorted output currents, reducing the distortion of the output voltage. Furthermore, an excellent distribution of currents between modules is achieved, resulting in fine power equalization between the inverters on stream. The crossover frequency of the different loop gains involved is moderate, so that robustness to variations of the operation point and to modeling uncertainties is achieved. A compara…
Experimental Validation of a Novel Method for Harmonic Mitigation for a Three-Phase Five-Level Cascaded H-Bridges Inverter
2019
In modern high-power electrical drives, the efficiency of the system is a crucial constraint. Moreover, the efficiency of power converters plays a fundamental role in modern applications requiring also a limited weight, such as the electric vehicles and novel more electric aircraft. The reduction of losses pushes for systems with a dc bus and a high number of dc/ac converters, widespread in the vehicle, not burdened by a too expensive data processing system. The purpose of this article is to concur to reduce losses by proposing an innovative selective harmonic mitigation method based on the identification of the working areas where the reference harmonics present lower amplitudes. In partic…
An Adaptive Robust Predictive Current Control for Three-Phase Grid-Connected Inverters
2011
This paper presents an adaptive robust predictive current control (RPCC) for grid-connected three-phase inverters that exhibit zero steady-state current error. The error correction is achieved by means of an adaptive strategy that works in parallel with the deadbeat algorithm, therefore preserving the typical fast response of the predictive law. The resulting control adapts to any particular L or LCL filter by estimation of the resistive part of the filter. As a variety of the RPCC class of control, it offers the best tradeoff between robustness and speed. © 2009 IEEE.
Analytical Investigation and Control System Set-up of Medium Scale PV Plants for Power Flow Management
2012
In the field of photovoltaic (PV) plants and energy conversion from renewable sources, a large part of the technical literature is more devoted to practical aspects (new solar cells, electrically driven PV panels, safety, reduction of parasitic currents, etc.) than to theoretical investigations. Despite this tendency, this paper presents a mathematical analysis of a medium scale photovoltaic power generation system connected to the distribution network and of its control system. In such a system, the conversion stage is unique due to the absence of a boost chopper. The conducted analysis leads to the interesting conclusion that the inverter used in the plant presents two degrees of freedom,…
Experimental validation of a general model for three phase inverters operating in healthy and faulty modes
2012
The paper presents the experimental verification of a general mathematical model of Voltage Source Inverters (VSI) able to simulate fault conditions and which is also useful for the simulation of fault-tolerant systems for different applications. In general, in the past, the problem of faulty inverters modeling has been addressed specifically by considering faults on the different phases as separate cases. Furthermore, traditional models include only the faulty mode and not the healthy mode, so resulting then not able to predict transient phenomena. The model hereafter presented overcomes this drawback. It was formulated by introducing the concept of “healthy leg binary variables”. Such var…