Search results for "ion source"

showing 10 items of 337 documents

Direct pyrolysis in the mass spectrometer of aromatic polysulfonates and polythiosulfonates

1978

The thermal degradation mechanism of three aromatic polysulfonates and polythiosulfonates was investigated by direct pyrolysis in the ion source of a mass spectrometer. Thermal degradation reactions were followed directly by this method by detecting the thermal and electron impact induced fragments. The results obtained have provided evidence that sulfur dioxide extrusion from the polymer backbone takes place in these polymers above 300°C. The synthesis and molecular characterization of the polymers studied are reported in the text.

chemistry.chemical_classificationchemistry.chemical_compoundchemistryAnalytical chemistryDegradation (geology)ExtrusionPolymerPhotochemistryMass spectrometryPyrolysisSulfur dioxideElectron ionizationIon sourceJournal of Polymer Science: Polymer Chemistry Edition
researchProduct

Strukturuntersuchung von polyestern durch direkten abbau im massenspektrometer, 1. Polyester der terephthalsäure

1976

Die Abbaureaktionen von Poly(athylenterephthalat) (1a), Poly(tetradeuteroathylenterephthalat) (1b), Poly(trimethylenterephthalat) (1c) und Poly(tetramethylenterephthalat) (1d) im Massenspektrometer wurden untersucht. Hierzu wurden die Polymeren direkt in der Ionenquelle des Massenspektrometers pyrolysiert und die entstehenden thermischen Bruchstucke durch Elektronenstos ionisiert und fragmentiert. Die thermisch- und elektronenstosinduzierten Abbaureaktionen lassen sich nebeneinander nachweisen. Die untersuchten polymeren Terephthalate 1a–d folgen in beiden Abbauschritten den gleichen Mechanismen und konnen anhand ihrer Pyrolyse-Massenspektren unterschieden werden. The degradation reactions …

chemistry.chemical_compoundEthylenechemistryPolymer chemistryMass spectrumDegradation (geology)Mass spectrometryPyrolysisElectron ionizationIon sourceDie Makromolekulare Chemie
researchProduct

A study of VUV emission and the extracted electron-ion ratio in hydrogen and deuterium plasmas of a filament-driven H−/D− ion source

2019

Vacuum ultraviolet (VUV) emission diagnostics for studying differences of electron impact processes in hydrogen and deuterium plasmas are presented. The method is applied to study a filament driven multicusp arc discharge negative ion source by comparing the VUV-emission intensities of different emission bands and extracted currents of H−/D− ions and electrons. It was found that the ratio of coextracted electrons to extracted ions is four times higher for deuterium than for hydrogen. No significant differences of the VUV-spectra or volumetric rates of ionization, excitation, production of high vibrational states, and dissociation were found between the plasmas of the two isotopes. The volum…

diffusion rateisotoopitplasma diagnosticselectron impact ionizationplasmafysiikkavacuum ultraviolet radiationelectron impact emission spectroscopyion sourcesPhysics::Plasma Physicselectric dischargesPhysics::Atomic and Molecular Clustersisotopesvibrational statesplasma spectroscopy
researchProduct

Measurement of the energy distribution of electrons escaping minimum-B ECR plasmas

2017

The measurement of the electron energy distribution (EED) of electrons escaping axially from a minimum-B electron cyclotron resonance ion source (ECRIS) is reported. The experimental data were recorded with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The electrons escaping through the extraction mirror of the ion source were detected with a secondary electron amplifier placed downstream from a dipole magnet serving as an electron spectrometer with 500 eV resolution. It was discovered that the EED in the range of 5–250 keV is strongly non-Maxwellian and exhibits several local maxima below 20 keV energy. It was observed that the most influential ion source operating pa…

electron energy distributionElectron spectrometerFOS: Physical sciencesElectronelektronitresonanssi01 natural sciences7. Clean energyElectron cyclotron resonanceSecondary electrons010305 fluids & plasmasmikroaallot0103 physical sciencesplasma010302 applied physicsPhysicsRange (particle radiation)energiaionitBremsstrahlungPlasmaCondensed Matter PhysicsIon sourcePhysics - Plasma PhysicsPlasma Physics (physics.plasm-ph)electrons escapingAtomic physics
researchProduct

Fission yield studies with SPIG-equipped IGISOL : a novel method for nuclear data measurements

2010

This thesis work consists of two sections. In the first section, the development of a so-called Laser Ion Source Trap (LIST) device is described. The LIST device is based on a double SPIG (SextuPole Ion Guide) system, providing the possibility to improve the elemental selectivity of the IGISOL method via highly discriminative laser ionization occurring outside the ion guide. The improved selectivity enables the production of isotopically pure beams. The double SPIG can be used without laser ionization and replaces the conventional skimmer electrode. In this work, the SPIG is compared to the skimmer and is shown to remarkably improve both the efficiency and beam quality of the IGISOL facilit…

fissioLaser Ion Source Trapydinreaktiotfission yieldIGISOLmeasurementsSPIGnuclear data
researchProduct

Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection of 23 Na 1+ ions

2016

This work describes the utilization of an injected 23Na1þ ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 1011 cm−3 or higher. The experimental results are compared to simulations of the 23Na1þ capture into th…

helium plasmaPhysics::Plasma Physicscharge breeder electron cyclotron resonance ion sourcesnatrium ion beam
researchProduct

Trace Analysis of Plutonium and Technetium by Resonance Ionization Mass Spectrometry Using an Atomic Beam and a Laser Ion Source

1990

A method for low level detection of plutonium and technetium is described with a detection limit of less than 107 atoms. Plutonium is a very toxic element due to its radioactive decay as well as its chemical behaviour. It was released to the environment in large amounts during the fifties and sixties of his century, principally by nuclear-weapon tests and some accidents. As a result about 0.4 − 4 mBq per gram 239Pu(T1/2 = 24390 y), corresponding to 4 × 108 − 4 × 109 atoms, can be found in the Northern Hemisphere in soil samples.

inorganic chemicalsStatic secondary-ion mass spectrometryMaterials scienceRadiochemistryAnalytical chemistryThermal ionizationchemistry.chemical_elementThermal ionization mass spectrometryMass spectrometryIon sourceAtmospheric-pressure laser ionizationPlutoniumchemistryDirect electron ionization liquid chromatography–mass spectrometry interface
researchProduct

Power efficiency improvements with the radio frequency H− ion source

2016

CW 13.56 MHz radio frequency-driven H− ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H− beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation of t…

ion sourcespower efficiency
researchProduct

Towards in-jet resonance ionization spectroscopy : An injection-locked Titanium:Sapphire laser system for the PALIS-facility

2018

This article presents a pulsed narrowband injection-locked Titanium:Sapphire laser aimed for high-resolution in-jet resonance ionization spectroscopy at the SLOWRI/PALIS at RIKEN. The laser has been integrated into the PALIS laser laboratory enabling it to be utilized with the existing broadband Titanium:Sapphire and dye lasers. The seed efficiency has been evaluated to be close to unity over the master laser wavelength range ∼ 753 to 791 nm, and the slope efficiency, namely the ratio of the pump power to the output power, was determined to be ∼ 30 % at 780 nm. A two-step ionization scheme with 386.4016 nm first step and 286.731 nm second step into an autoionizing state was developed for re…

laseritspektroskopialaser spectroscopylaserlaitteetPhysics::OpticsPhysics::Atomic Physicslaser resonance ionizationlaser developmentlaser ion source
researchProduct

Removal of molecular contamination in low-energy RIBs by the isolation-dissociation-isolation method

2020

Nuclear instruments & methods in physics research / B 463, 324 - 326 (2020). doi:10.1016/j.nimb.2019.04.072

low-energy RIBNuclear and High Energy PhysicsMaterials scienceCollision-induced dissociationbeam purificationtutkimuslaitteet53001 natural sciencesDissociation (chemistry)RF-quadrupolelaw.inventionIonlawDipole magnet0103 physical sciencesddc:530Instrumentation010308 nuclear & particles physics010401 analytical chemistryContaminationSynchrotronIon source0104 chemical sciencesmolecular contaminationBeamlinecollision-induced dissociationPhysics::Accelerator PhysicsAtomic physicsydinfysiikkaNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct