Search results for "ion source"
showing 10 items of 337 documents
Design of a 10 GHz minimum-B quadrupole permanent magnet electron cyclotron resonance ion source
2020
This paper presents a simulation study of a permanent magnet electron cyclotron resonance ion source (ECRIS) with a minimum-B quadrupole magnetic field topology. The magnetic field is made to conform to conventional ECRIS with $B_\textrm{min}/B_\textrm{ECR}$ of 0.67 and a last closed magnetic isosurface of 1.86$B_\textrm{ECR}$ at 10 GHz. The distribution of magnetic field gradients parallel to the field, affecting the electron heating efficiency, cover a range from 0 to 13 T/m, being similar to conventional ECRIS. Therefore it is expected that the novel ion source produces warm electrons and high charge state ions in significant number. Single electron tracking simulations are used to estim…
Information sources and knowledge on vaccination in a population from southern Italy: The ESCULAPIO project
2016
Vaccine knowledge of the general population is shaped by different information sources and strongly influences vaccination attitudes and uptake. The CCM-Italian Ministry of Health ESCULAPIO project attempted to identify the role of such information sources, in order to address adequate strategies to improve information on vaccines and vaccine preventable diseases. In the present study, data on 632 adults from Southern Italy regarding information sources were collected, and their perceived and actual knowledge on vaccinations were compared and analyzed in relation to socio-demographic characteristics and information sources. The main reported reference sources were general practitioners (GPs…
COVID–19. Effect of Moral Messages to Persuade the Population to Stay at Home in Spain, Chile, and Colombia
2021
1.362 / 5.000 Resultados de traducción Analizar si el contenido de tres mensajes morales (deontológico, utilitarismo ético, virtud ética) y un mensaje de control afectan diferencialmente la probabilidad de realizar cuatro comportamientos: lavarse las manos, participar en reuniones públicas, quedarse en casa/evitar el contacto social y reenviar el mensaje para informar a más personas. En nuestro estudio, el emisor del mensaje es un profesor universitario. Estas variables se miden en términos de sus intenciones de comportamiento y las intenciones de comportamiento de los demás (creencias sobre el comportamiento de los demás). Ensayo controlado aleatorizado. Nuestro estudio incluye el análisis…
Real-Time Analysis of Ambient Organic Aerosols Using Aerosol Flowing Atmospheric-Pressure Afterglow Mass Spectrometry (AeroFAPA-MS).
2015
Organic compounds contribute to a major fraction of atmospheric aerosols and have significant impacts on climate and human health. However, because of their chemical complexity, their measurement remains a major challenge for analytical instrumentation. Here we present the development and characterization of a new soft ionization technique that allows mass spectrometric real-time detection of organic compounds in aerosols. The aerosol flowing atmospheric-pressure afterglow (AeroFAPA) ion source is based on a helium glow discharge plasma, which generates excited helium species and primary reagent ions. Ionization of the analytes occurs in the afterglow region after thermal desorption and pro…
Identification of organic hydroperoxides and hydroperoxy acids in secondary organic aerosol formed during the ozonolysis of different monoterpenes an…
2009
On-line ion trap mass spectrometry (ITMS) enables the real-time characterization of reaction products of secondary organic aerosol (SOA). The analysis was conducted by directly introducing the aerosol particles into the ion source. Positive-ion chemical ionization at atmospheric pressure (APCI(+)) ITMS was used for the characterization of constituents of biogenic SOA produced in reaction-chamber experiments. APCI in the positive-ion mode usually enables the detection of [M+H](+) ions of the individual SOA components. In this paper the identification of organic peroxides from biogenic volatile organic compounds (VOCs) by on-line APCI-ITMS is presented. Organic peroxides containing a hydroper…
Characterization of oligomeric compounds in secondary organic aerosol using liquid chromatography coupled to electrospray ionization Fourier transfor…
2009
The components of secondary organic aerosols (SOAs) generated from the gas-phase ozonolysis of two C(10)H(16)-terpenes (alpha-pinene; sabinene) and a cyclic C(6)H(10) alkene (cyclohexene) were characterized by the use of a Fourier transform ion cyclotron mass spectrometer equipped with an electrospray ionization source operated in the negative ion mode. Reversed-phase high-performance liquid chromatography was used to achieve chromatographic separation of highly oxidized organic compounds. In addition to the well-known group of low molecular weight oxidation products (monomers; e.g. dicarboxylic acids), higher molecular weight compounds (dimers) were also detected and their exact elemental …
Combined target and post-run target strategy for a comprehensive analysis of pesticides in ambient air using liquid chromatography-Orbitrap high reso…
2014
Abstract A comprehensive strategy for the analysis of current airborne pesticides has been developed using liquid chromatography coupled to high resolution mass spectrometry. The methodology includes both quantitative target analysis and post-run target screening analysis. The quantitative method was validated after a previous statistical optimisation of the main factors governing the ion source ionization and a study of the single-stage Orbitrap fragmentation through the HCD cell. The quantitative method presented recoveries ranging from 73 to 116%, with precision (RSD) lower than 20%, for the 35 substances in the scope of the target method. The full-scan accurate mass data were acquired w…
Low vacuum photo electron emitting thin films
2009
Impact ionisation is a standard procedure to ionise gaseous or vaporisable substances in organic mass spectrometry. In this work, a "softer" ionisation is introduced which seems to be an alternative ion source for reducing collision between substance molecules and the hot internal walls of the box. Through collision mainly found in impact ionisation sources, fragments are built especially from thermally sensitive substances falsifying the spectra. We present here photoelectron emitting materials for the soft ionisation using semiconducting compounds, galliumn nitride (GaN), and a representative of the borides, lanthanum hexaboride (LaB 6 ). They are evaluated by photoelectron spectroscopic …
Determination of the number densities of argon metastables in argon-hydrogen plasma by absorption and self-absorption methods
2006
The number densities of Ar 3s23p54s levels have been measured by means of two methods: a self-absorption method with a mirror behind the discharge vessel and an absorption method with a high-frequency electrodeless discharge lamp. Concentrations ranging from 6 × 107–4 × 109 cm−3 were obtained for the Ar 3s23p54s levels, depending on the argon content (10–100% Ar) in Ar/H2 microwave plasma. The populations of various sublevels of measured resonant and metastable states coincide within the experimental errors. It was observed that values from measurements of both methods are in good agreement.
The airborne mass spectrometer AIMS – Part 2: Measurements of trace gases with stratospheric or tropospheric origin in the UTLS
2016
Understanding the role of climate-sensitive trace gas variabilities in the upper troposphere and lower stratosphere region (UTLS) and their impact on its radiative budget requires accurate measurements. The composition of the UTLS is governed by transport and chemistry of stratospheric and tropospheric constituents, such as chlorine, nitrogen oxide and sulfur compounds. The Atmospheric chemical Ionization Mass Spectrometer AIMS has been developed to accurately measure a set of these constituents on aircraft by means of chemical ionization. Here we present a setup using SF5− reagent ions for the simultaneous measurement of trace gas concentrations of HCl, HNO3 and SO2 in the pptv to ppmv (1…