Search results for "ionic"
showing 10 items of 2016 documents
Study of the effect of the membrane composition on ion transfer across a supported liquid membrane
2003
Abstract The rate of ion transfer across the supported liquid membrane (SLM) is studied in the rotating diffusion cell (RDC), varying the chemical composition of the SLM from net-cloth supported gel membranes to radiation-grafted polymer membranes. Steady-state current–voltage curves are measured as a function of the rotation rate, and values for the standard rate constant, k 0 , are determined for a series of tetraalkylammonium cations from the analysis of the initial slopes and the diffusion limiting currents. The analysis gives values for k 0 of the order of 10 −2 –10 −4 cm s −1 , which is in rather good agreement with the values found in the literature for this type of the system. As co…
Comparison of the performance of non-ionic and anionic surfactants as mobile phase additives in the RPLC analysis of basic drugs
2011
Surfactants added to the mobile phases in reversed-phase liquid chromatography (RPLC) give rise to a modified stationary phase, due to the adsorption of surfactant monomers. Depending on the surfactant nature (ionic or non-ionic), the coated stationary phase can exhibit a positive net charge, or just change its polarity remaining neutral. Also, micelles in the mobile phase introduce new sites for solute interaction. This affects the chromatographic behavior, especially in the case of basic compounds. Two surfactants of different nature, the non-ionic Brij-35 and the anionic sodium dodecyl sulfate (SDS) added to water or aqueous-organic mixtures, are here compared in the separation of basic …
Quantitative Retention−Structure and Retention−Activity Relationship Studies of Local Anesthetics by Micellar Liquid Chromatography
2011
The retention of compounds in micellar liquid chromatography (MLC) is governed by hydrophobic and electrostatic forces. For ionic compounds, both interactions should be considered. The present report offers a novel retention model that includes the hydrophobicity of compounds and the molar fraction of the charged form of compounds and compares it with other previously reported models. High correlations between the logarithm of capacity factors and these structural parameters were obtained for local anesthetics with different degrees of ionization using a nonionic surfactant solution as mobile phase. Modeling the retention of compounds as a function of physicochemical parameters and experime…
Quantitative retention—structure and retention—activity relationship studies of ionic and non-ionic catecholamines by micellar liquid chromatography
1997
When ionic surfactants are used as mobile phases in micellar liquid chromatography, MLC, the retention of compounds is governed by hydrophobic and electrostatic forces. In the absence of electrostatic effects, the hydrophobicity of a compound is the predominant factor affecting its retention and its interaction with micelles. Because both interactions should be considered for ionic compounds, a novel retention model is proposed which includes the hydrophobicity of a compound and the molar fraction of its charged form. High correlations between the logarithm of the capacity factors and structural parameters were obtained for ionic compounds with different degrees of ionization. The effect of…
Micellar versus hydro-organic reversed-phase liquid chromatography: a solvation parameter-based perspective.
2007
The performance of the solvation parameter model is examined for micellar liquid chromatography. The results are compared with those offered with hydro-organic eluents, intending to reveal the properties that influence the retention and distinguish the particular behaviour of micellar systems. The retention data of several series of non-ionisable and ionisable compounds (mainly steroids, polyaromatic hydrocarbons, phenols, sulfonamides, beta-blockers, phenethylamines, antihistamines, and diuretics) were used as probe compounds. The micellar mobile phases contained an anionic (sodium dodecyl sulphate), non-ionic (Brij-35), or cationic (cetyltrimethylamonium bromide) surfactant, with or witho…
Retention mechanisms in micellar liquid chromatography.
2008
Micellar liquid chromatography (MLC) is a reversed-phase liquid chromatographic (RPLC) mode with mobile phases containing a surfactant (ionic or non-ionic) above its critical micellar concentration (CMC). In these conditions, the stationary phase is modified with an approximately constant amount of surfactant monomers, and the solubilising capability of the mobile phase is altered by the presence of micelles, giving rise to diverse interactions (hydrophobic, ionic and steric) with major implications in retention and selectivity. From its beginnings in 1980, the technique has evolved up to becoming a real alternative in some instances (and a complement in others) to classical RPLC with hydro…
Ionic liquids in separation techniques.
2007
The growing interest in ionic liquids (ILs) has resulted in an exponentially increasing production of analytical applications. The potential of ILs in chemistry is related to their unique properties as non-molecular solvents: a negligible vapor pressure associated to a high thermal stability. ILs found uses in different sub-disciplines of analytical chemistry. After drawing a rapid picture of the physicochemical properties of selected ILs, this review focuses on their use in separation techniques: gas chromatography (GC), liquid chromatography (LC) and electrophoretic methods (CE). In LC and CE, ILs are not used as pure solvents, but rather diluted in aqueous solutions. In this situation IL…
Separation of selected peptides by capillary electroendoosmotic chromatography using 3 μm reversed-phase bonded silica and mixed-mode phases
1999
The retention behaviour and selectivity of selected basic, neutral and acidic peptides have been studied by capillary electroendoosmotic chromatography (CEC) with Hypersil C8, C18, Hypersil mixed-mode, and Spherisorb C18/SCX columns, 250 (335) mm x 100 microns, packed with 3 microns particles, and eluted with mobile phases composed of acetonitrile-triethylamine-phosphoric acid (TEAP) at pH 3.0 using a Hewlett-Packard Model HP3DCE capillary electrophoresis system. The selected peptides were desmopressin (D), two analogues (A and B) of desmopressin, oxytocin (O) and carbetocin (C). The peptides eluted either before or after the electroendoosmotic flow (EOF) marker, depending on the concentrat…
Are deep eutectic solvents useful in chromatography? A short review.
2021
A literature update has been done concerning Deep Eutectic Solvents (DES) use in chromatography applications. The literature survey was based on the period from 2010 till 2020 and manuscripts reported in the data bases Web of Science and Scopus. The use of DES as mobile phase and mobile phase additives, stationary phases and solid phase modifiers and the use of DES as reaction solvents for chromatography use, were evaluated. Emphasis was placed on the differentiation of DES and Ionic Liquids (ILs) and the advanced green characteristics of the new solvents as compared with traditional organic solvents and ILs with a look into the drawbacks and future perspectives in the field of separation m…
Analysis of tricyclic antidepressants in pharmaceuticals by microemulsion liquid chromatography
2021
Abstract Basic compounds yield long retention times and broad and asymmetric peaks in reversed-phase liquid chromatography, due to interaction with residual silanols in the columns. The addition of the surfactant sodium dodecyl sulphate in the so called micellar liquid chromatography enhances the efficiency, but long retention is achieved, due to electrostatic interaction between the cationic species of basic compounds and the anionic sulphate group of the surfactant. This forces the addition of a strong organic solvent to get appropriate times. An alternative is the use of a microemulsion (ME), formed by mixing surfactant, oil and an alcohol as co-surfactant. Association of hydrophobic com…