Search results for "ioniohjain"

showing 3 items of 3 documents

Resonance laser ionization developments for IGISOL-4

2012

The work presented in this thesis concentrates on the development of the FURIOS laser ion source towards e cient and selective production of low energy radioactive ion beams. This includes design and development of the ion guide and hot cavity catcher systems for laser ion source use, and the development of in-source and in-jet laser spectroscopy techniques. The work has been carried out at the IGISOL facility in the Accelerator laboratory of the University of Jyväskylä. The FURIOS facility was upgraded and developed during the move to the IGISOL-4 facility. The laser transport was greatly improved in order to allow a large fraction of the initial laser intensity to be transported into the …

Laser resonance ionizationlaseritlaserresonanssi-ionisaatioionitioniohjainionisoiva säteilyspektroskopiaNuclear physicsIGISOLLaser spectroscopylaserspektroskopiaydinfysiikkaIon guide
researchProduct

Ion yields in HIGISOL experiments based on JYFLTRAP data and PACE4 simulations : based on JYFLTRAP data and PACE4 simulations

2012

The purpose of this thesis was to calculate ion yields in the neutron-deficient mass region A=78-111 in heavy-ion ion-guide experiments at the Ion Guide Isotope Separator On-Line (IGISOL) facility in the Accelerator Laboratory of the University of Jyväskylä. The biggest challenge was that the experiments were not designed for yield calculations but for precision mass measurements. Therefore, only a small fraction of the available data could be used. The results were compared to theoretical cross sections calculated with PACE4 code. Ion yields agreed roughly with the cross-section calculations: On the one hand, the ions with the highest cross sections were detected. On the other hand, ratios…

ionitioniohjainionituottoJYFLTRAPIGISOL
researchProduct

An off-line ion guide quadrupole mass spectrometer system

2017

Off-line ioniohjain kvadrupolimassaspektrometri systeemi. Uuden erillisen ioniohjain-kvadrupolimassaspektrometri (IGQMS) -systeemin käyttöönotto on esitetty tässä työssä. Laitteisto on kehitetty uusien tekniikoiden testaamiseen ja kehittämiseen IGISOL–laitoksella. Työssä on tutkittu laitteiston differentiaalista pumpaussysteemiä ja laitteiston etuosan kuljetustehokkuutta käyttäen 223Ra alfa-rekyylilähdettä. Painemittausten tulokset eri parametreilla ovat esitetty. Kaasuohjaimen käyttöpainealue on mitattu olevan 1 ja 700 mbar:n välillä pitäen käyttöpaineen QMS kammiossa, ja skimmer-systeemin läpäisytehokkuus olevan lähellä 100 %. The commissioning of a new off-line ion guide quadrupole mass …

massaspektrometriaionittehokkuusvacuumion guideoperational pressureoff-lineioniohjainefficiencykäyttöpainemass spectrometerIGISOLydinfysiikkatyhjiö
researchProduct