Search results for "itt"
showing 10 items of 20843 documents
Phase transitions in Na0.5Bi0.5TiO3-(Sr0.7Bi0.2)TiO3-PbTiO3 solid solutions
2016
ABSTRACTIncreasing of Sr0.7Bi0.2TiO3 concentration in Na0.5Bi0.5TiO3-Sr0.7Bi0.2TiO3 solid solutions causes increasing of Bi/Na relation and vacancies in the A-site of perovskite structure. In temperature dependence of dielectric permittivity, such a change of composition is reflected by transforming of the frequency-dependent shoulder into a maximum characteristic for relaxor ferroelectrics and diminishing of the frequency-independent maximum characteristic for Na0.5Bi0.5TiO3. Here changes in behavior of dielectric permittivity and polarization are studied if PbTiO3 is added in a certain concentration range of Na0.5Bi0.5TiO3-Sr0.7Bi0.2TiO3 solid solutions. Changes of the characteristic temp…
High-frequency EPR study on Cu4Cu- and Co4Co-metallacrown complexes
2019
Abstract High-frequency/high-field electron paramagnetic resonance studies on two homonuclear 12-MC-4 metallacrown complexes Cu4Cu and Co4Co are presented. For Cu4Cu, our data imply axial-type g-anisotropy with g x = 2.03 ± 0.01 , g y = 2.04 ± 0.01 , and g z = 2.23 ± 0.01 , yielding g = 2.10 ± 0.02 . No significant zero field splitting (ZFS) of the ground state mode is observed. In Co4Co, we find a m S = ± 3 / 2 ground state with g = 2.66 . The data suggest large anisotropy D of negative sign.
Hot-cavity studies for the Resonance Ionization Laser Ion Source
2016
International audience; The Resonance Ionization Laser Ion Source (RILIS) has emerged as an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability, and ability to ionize target elements efficiently and element selectively. GISELE is an off-line RILIS test bench to study the implementation of an on-line laser ion source at the GANIL separator facility. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. The ion source geometry was tested in several configurations in order to find a solution with optimal ionization efficiency an…
H− extraction systems for CERN’s Linac4 H− ion source
2018
Abstract Linac4 is a 160 MeV linear H − accelerator at CERN. It is an essential part of the beam luminosity upgrade of the Large Hadron Collider (LHC) and will be the primary injector into the chain of circular accelerators. It aims at increasing the beam brightness by a factor of 2, when compared to the currently used 50 MeV linear proton accelerator, Linac2. Linac4’s ion source is a cesiated RF-plasma H − ion source. Several beam extraction systems were designed for H − beams of 45 keV energy, 50 mA intensity and an electron to H − ratio smaller than 5. The goal was to extract a beam with an rms-emittance of 0 . 25 π mm mrad. One of the main challenges in designing an H − extraction…
The effect of plasma electrode collar structure on the performance of the JYFL 14GHz electron cyclotron resonance ion source
2013
Abstract The influence of a so-called collar structure on the performance of the JYFL 14 GHz electron cyclotron resonance ion source (ECRIS) has been studied experimentally at the Department of Physics, University of Jyvaskyla (JYFL). The collar is a cylindrical structure extruding inwards from the plasma electrode. The collar length was varied between 5 and 60 mm. For some ion species a moderate performance improvement was achieved in terms of extracted beam current and transverse emittance up to 30 mm collar length. Longer collars resulted in a substantial performance decrease. Different collar materials, i.e. nonmagnetic stainless steel, aluminum and Al 2 O 3 , and a wide range of ion sp…
Time resolved measurements of hydrogen ion energy distributions in a pulsed 2.45 GHz microwave plasma
2017
A plasma diagnostic study of the Ion Energy Distribution Functions (IEDFs) of H+, H+2H2+, and H+3H3+ ions in a 2.45 GHz hydrogen plasma reactor called TIPS is presented. The measurements are conducted by using a Plasma Ion Mass Spectrometer with an energy sector and a quadrupole detector from HIDEN Analytical Limited in order to select an ion species and to measure its energy distribution. The reactor is operated in the pulsed mode at 100 Hz with a duty cycle of 10% (1 ms pulse width). The IEDFs of H+, H+2H2+, and H+3H3+ are obtained each 5 μs with 1 μs time resolution throughout the entire pulse. The temporal evolution of the plasma potential and ion temperature of H+ is derived from the d…
Charge breeding at GANIL: Improvements, results, and comparison with the other facilities
2019
International audience; The 1+/n+ method, based on an ECRIS charge breeder (CB) originally developed at the LPSC laboratory, is now implemented at GANIL for the production of Radioactive Ion Beams (RIBs). Prior to its installation in the middle of the low energy beam line of the SPIRAL1 facility, the 1+/n+ system CB has been modified based on the experiments performed on the CARIBU Facility at Argone National Laboratory. Later, it has been tested at the 1+/n+ LPSC test bench to validate its operation performances. Charge breeding efficiencies as well as charge breeding times have been measured for noble gases and alkali elements. The commissioning phase started at GANIL in the second half-y…
Unveiling the Occurrence of Co(III) in NiCo Layered Electroactive Hydroxides: The Role of Distorted Environments
2020
Co- and Ni-based layered hydroxides constitute a unique class of two-dimensional inorganic materials with exceptional chemical diversity, physicochemical properties and outstanding performance as supercapacitors and overall water splitting catalysts. Recently, the occurrence of Co(III) in these phases has been proposed as a key factor that enhance their electrochemical performance. However, the origin of this centers and control over its contents remains as an open question. We employed the Epoxide Route to synthesize a whole set of α-NiCo layered hydroxides. The PXRD and XAS characterization alert about the occurrence of Co(III) as a consequence of the increment in the Ni content. DFT+U si…
Reversible O–H bond activation by an intramolecular frustrated Lewis pair
2019
The interactions of the O-H bonds in alcohols, water and phenol with dimethylxanthene-derived frustrated Lewis pairs (FLPs) have been probed. Within the constraints of this backbone framework, the preference for adduct formation or O-H bond cleavage to give the corresponding zwitterion is largely determined by pKa considerations. In the case of the PPh2/B(C6F5)2 system and p-tBuC6H4OH, an equilibrium is established between the two isomeric forms which allows the thermodynamic parameters associated with zwitterion formation via O-H bond cleavage to be probed.
Influence of the solvent and R groups on the structure of (carboranyl)R2PI2 compounds in solution. Crystal structure of the first iodophosphonium sal…
2008
The influence of the electron-donor or electron-acceptor capacity of the R groups (R = (i)Pr, Ph, Et) and the solvent on the molecular geometry in solution of adducts of carboranylphosphanes [(carboranyl)(i)Pr2P, (carboranyl)Ph2P and (carboranyl)Et2P] with I2 in 1 : 1 ratios, has been studied in detail by 31P{1H} and 11B{1H} NMR spectroscopies. The more electron-accepting Ph groups make the (carboranyl)Ph2P less nucleophilic, thus stabilizing the I2 encapsulated neutral biscarboranylphosphane-diiodine adducts in solution, such as (carboranyl)Ph2PI-IPPh2(carboranyl), generating P---I-I---P motifs. Even in a polar solvent, such as EtOH, the arrangement is preserved. The expected basicity of t…