Search results for "kuntotestit"

showing 10 items of 51 documents

Recent advances in machine learning for maximal oxygen uptake (VO2 max) prediction : A review

2022

Maximal oxygen uptake (VO2 max) is the maximum amount of oxygen attainable by a person during exercise. VO2 max is used in different domains including sports and medical sciences and is usually measured during an incremental treadmill or cycle ergometer test. The drawback of directly measuring VO2 max using the maximal test is that it is expensive and requires a fixed and controlled protocol. During the last decade, various machine learning models have been developed for VO2 max prediction and numerous studies have attempted to predict VO2 max using data from submaximal and non-exercise tests. This article gives an overview of the machine learning models developed over the past five years (…

Artificial neural networkmallintaminenComputer applications to medicine. Medical informaticsR858-859.7ennusteetneuroverkotkuntotestitPrediction modelsError metricsmittaustekniikkafyysinen kuntokoneoppiminenGraded exercise testsMachine learningmaksimaalinen hapenottoMaximal oxygen uptake (VO2 max)
researchProduct

Age and sex-based differences in functional strength of adults participating in Special Olympics

2022

Muscular strength is a critical component of physical health. The aim of this cross-sectional study was to examine age- and sex-based differences in functional strength and rates of referral for education in a large international sample of Special Olympics athletes. A total of 30,358 (male = 19,661) adult (20–69 years old) athlete functional strength records were utilized from the Special Olympics Healthy Athletes database. Descriptive statistics were computed for the following tests: timed sit to stand, partial sit-up, grip strength, and seated push-up. Analyses of variance with Fisher-Hayter pairwise comparisons generally supported age-related decreases in strength among both males and fe…

FUNfitness test batteryeducationHealth (social science)Social PsychologyscreeningPhysical Therapy Sports Therapy and RehabilitationhealthkuntotestitSpecial OlympicsEducationathletesintellectual disabilityfitness testingvoimaharjoittelukehitysvammaisetkuntourheilijat
researchProduct

A New Fitness Test of Estimating VO2max in Well-Trained Rowing Athletes

2021

BackgroundThis study was designed to investigate the validity of maximal oxygen consumption (VO2max) estimation through the Firstbeat fitness test (FFT) method when using submaximal rowing and running programs for well-trained athletes.MethodsWell-trained flatwater rowers (n = 45, 19.8 ± 3.0 years, 184 ± 8.7 cm, 76 ± 12.9 kg, and 58.7 ± 6.0 mL⋅kg–1⋅min–1) and paddlers (n = 45, 19.0 ± 2.5 years, 180 ± 7.7 cm, 74 ± 9.4 kg, and 59.9 ± 4.8 mL⋅kg–1⋅min–1) completed the FFT and maximal graded exercise test (GXT) programs of rowing and running, respectively. The estimated VO2max was calculated using the FFT system, and the measured VO2max was obtained from the GXT programs. Differences between the…

Intraclass correlationPhysiologyRowingFast Fourier transformsoutu030204 cardiovascular system & hematologykuntotestitmaximal aerobic capacity03 medical and health sciences0302 clinical medicinePhysiology (medical)StatisticsTest programQP1-981treadmill runningflatwater paddlersMathematicsOriginal Researchhapenottorowingbiologysubmaximal fitness testAthletesVO2 max030229 sport sciencesbiology.organism_classificationflatwater rowersmittausmenetelmätmittaustekniikkaFitness testMean absolute percentage errormittarit (mittaus)juoksumatotaerobinen suorituskykyurheilijatFrontiers in Physiology
researchProduct

Validity of Hip-worn Inertial Measurement Unit Compared to Jump Mat for Jump Height Measurement in Adolescents

2018

Jump tests assess lower body power production capacity, and can be used to evaluate athletic ability and development during growth. Wearable inertial measurement units (IMU) seem to offer a feasible alternative to laboratory-based equipment for jump height assessments. Concurrent validity of these devices for jump height assessments has only been established in adults. Therefore, the purpose of this study was to evaluate the concurrent validity of IMU-based jump height estimate compared to contact mat-based jump height estimate in adolescents. Ninety-five adolescents (10-13 years-of-age; girls N = 41, height = 154 (SD 9) cm, weight = 44 (11) kg; boys N = 54, height = 156 (10) cm, weight = 4…

MaleAdolescentConcurrent validity030209 endocrinology & metabolismPhysical Therapy Sports Therapy and RehabilitationAthletic PerformancekuntotestitAccelerometerwearableWearable Electronic Devices03 medical and health sciencesVertical jump0302 clinical medicineLower bodyInertial measurement unitStatisticsHumansOrthopedics and Sports MedicineChildta315MathematicsLimits of agreementReproducibility of Resultsmethodology030229 sport sciencesFlight timemittausmenetelmätaccelerometerExercise TestJumpFemalehyppääminenconcurrentScandinavian Journal of Medicine and Science in Sports
researchProduct

Relative peak exercise oxygen pulse is related to sudden cardiac death, cardiovascular and all-cause mortality in middle-aged men

2018

Background Preliminary evidence suggests that peak exercise oxygen pulse – peak oxygen uptake/heart rate-, a variable obtained during maximal cardiopulmonary exercise testing and a surrogate of stroke volume, is a predictor of mortality. We aimed to assess the associations of peak exercise oxygen pulse with sudden cardiac death, fatal coronary heart disease and cardiovascular disease and all-cause mortality. Design A prospective study. Methods Peak exercise oxygen pulse was assessed in a maximal cycling test at baseline in 2227 middle-aged men of the Kuopio Ischaemic Heart Disease cohort study using expired gas variables and electrocardiograms. Relative peak exercise oxygen pulse was obtain…

MaleEpidemiologyDisease030204 cardiovascular system & hematologySudden cardiac deathrisk prediction0302 clinical medicineHeart RateRisk Factorscardiovascular diseaseCause of DeathMedicineProspective Studies030212 general & internal medicineäkkikuolemata315FinlandPulse (signal processing)Age FactorsVO2 maxta3141Stroke volumeta3142riskitekijätMiddle AgedPrognosispeak exercise oxygen pulseCardiovascular DiseasesCardiologyall-cause mortalityaerobinen suorituskykyCardiology and Cardiovascular MedicineCohort studymedicine.medical_specialtyOxygen pulsekuntotestitcardiopulmonary exercise testinRisk Assessmentsudden cardiac death03 medical and health sciencesOxygen ConsumptionSex FactorsPeak exercise oxygen pulsePredictive Value of TestsInternal medicineHeart ratecardiopulmonary exercise testingHumanssydäntauditbusiness.industrymedicine.diseaseDeath Sudden CardiacPhysical FitnessExercise Testsydän- ja verisuonitauditbusiness
researchProduct

The Duke treadmill score with bicycle ergometer: Exercise capacity is the most important predictor of cardiovascular mortality

2018

Background The Duke treadmill score, a widely used treadmill testing tool, is a weighted index combining exercise time or capacity, maximum ST-segment deviation and exercise-induced angina. No previous studies have investigated whether the Duke treadmill score and its individual components based on bicycle exercise testing predict cardiovascular death. Design Two populations with a standard bicycle testing were used: 3936 patients referred for exercise testing (2371 men, age 56 ± 13 years) from the Finnish Cardiovascular Study (FINCAVAS) and a population-based sample of 2683 men (age 53 ± 5.1 years) from the Kuopio Ischaemic Heart Disease study (KIHD). Methods Cox regression was applied for…

MaleTime FactorsEpidemiologyDuke treadmill score030204 cardiovascular system & hematologyFull Research PaperAngina0302 clinical medicineRisk Factorscardiovascular mortalityCause of DeathMedicine030212 general & internal medicineSegment deviationta315FinlandExercise ToleranceSisätaudit - Internal medicineta3141Exercise capacityTreadmill testingMiddle AgedPrognosisfyysinen kuntoCardiorespiratory FitnessCardiovascular DiseasesCardiologyBody Compositionstress testFemaleBicycle ergometerCardiology and Cardiovascular MedicineRisk PredictionAdultkuolleisuusmedicine.medical_specialtyBiolääketieteet - BiomedicinekuntotestitRisk Assessment03 medical and health sciencesPredictive Value of TestsInternal medicineHumansCardiovascular mortalityAgedbusiness.industryprognostic factorsennusteet217 Medical engineeringmedicine.diseaseBicyclingPhysical Fitness3121 General medicine internal medicine and other clinical medicineExercise Testsydän- ja verisuonitauditStock price indexbusiness
researchProduct

Precision exercise medicine: predicting unfavourable status and development in the 20-m shuttle run test performance in adolescence with machine lear…

2021

Objectives: To assess the ability to predict individual unfavourable future status and development in the 20m shuttle run test (20MSRT) during adolescence with machine learning (random forest (RF) classifier). Methods: Data from a 2-year observational study (2013‒2015, 12.4±1.3 years, n=633, 50% girls), with 48 baseline characteristics (questionnaires (demographics, physical, psychological, social and lifestyle factors), objective measurements (anthropometrics, fitness characteristics, physical activity, body composition and academic scores)) were used to predict: (Task 1) unfavourable future 20MSRT status (identification of individuals in the lowest 20MSRT tertile after 2 years), and (Task…

Medicine (General)fyysinen kuntochildren's health and exerciseR5-920koneoppiminennuoretadolescentphysical fitnessennusteet1506kuntotestitsports & exercise medicineOriginal ResearchBMJ Open Sport — Exercise Medicine
researchProduct

Heart rate responses during the modified six-minute walk test among Special Olympics athletes

2021

Objective: The construct validity of the modified six-minute walk test (m6MWT) was examined by addressing the following questions: 1) do participants attain a steady state plateau in heart rate (HR) within the range of 110-150 beats per minute? 2) at what percentage of their predicted HR maximum were participants during each minute of the test? Material and Methods: Participants were 36 (male=56%) Special Olympics athletes aged 34.4 years (SD = 12.7). Following familiarization, participants completed the m6MWT while wearing a Polar Team 2 heart rate monitor. Results: By the end of the first minute, average heart rate was 120bpm, and a factorial repeated measures ANOVA revealed that steady s…

Validation studySIX MINUTE WALKmedicine.medical_specialtyPhysical Fitness TestingkuntotestitHeart rateMedicineadaptive sportskehitysvammaisetinstrumentationcardiorespiratory fitnessbiologyAthletesbusiness.industryCardiorespiratory fitnesserityisliikuntabiology.organism_classificationTest (assessment)fyysinen kuntovalidation studyvalidointiGV557-1198.995Sports medicinePhysical therapyphysical fitness testingbusinessRC1200-1245Sports
researchProduct

Validity of Hip-worn Inertial Measurement Unit Compared to Jump Mat for Jump Height Measurement in Adolescents

2018

Jump tests assess lower body power production capacity, and can be used to evaluate athletic ability and development during growth. Wearable inertial measurement units (IMU) seem to offer a feasible alternative to laboratory‐based equipment for jump height assessments. Concurrent validity of these devices for jump height assessments has only been established in adults. Therefore, the purpose of this study was to evaluate the concurrent validity of IMU‐based jump height estimate compared to contact mat‐based jump height estimate in adolescents. Ninety‐five adolescents (10‐13 years‐of‐age; girls N = 41, height = 154 (SD 9) cm, weight = 44 (11) kg; boys N = 54, height = 156 (10) cm, weight = 4…

accelerometermetodologiahyppääminenconcurrentkuntotestitwearablemittausmenetelmät
researchProduct

Kehitysvammaisten aikuisten kestävyyskunnon taso ja muutos ikääntyessä : kahden kävelytestin vertaaminen

2015

Eveliina Keinonen (2015). Kehitysvammaisten aikuisten kestävyyskunnon taso ja muutos ikääntyessä: Kahden kävelytestin vertaaminen. Liikuntakasvatuksen laitos, Jyväskylän yli-opisto, liikuntapedagogiikan pro gradu –tutkielma, 66 s., 3 liitettä. Tutkimuksen tavoitteena oli tarkastella keski-ikäisten kehitysvammaisten naisten ja miesten kestävyyskunnon tasoa vammattomaan väestöön sekä Suomessa yleisesti käytössä oleviin terveysliikunnan suosituksiin verrattuna. Tarkastelun kohteena oli myös kehitysvammaisten kestävyyskunnossa esiintyvät muutokset seitsemän vuoden aikana. Lisäksi tutkimus pyrki selvittämään onko samanaikaisesti suoritettujen UKK-instituutin 2 kilometrin kävelytestin ja Rockport…

aerobic capacitycardiovascular fitness testingkehitysvammaisuusfyysinen kuntokestävyyskunnon mittaaminenkestävyyskuntointellectual disabilitykuntotestitkehitysvammaiset
researchProduct