Search results for "laser"
showing 10 items of 3161 documents
Infrequent early recanalization of greater saphenous vein after endovenous laser treatment
2003
Abstract Objective The frequency of recanalization of the greater saphenous vein (GSV) after endovenous laser treatment (ELT) is unclear. This study was undertaken to establish the incidence of early recanalization after ELT and to study the histopathologic features of reperfused and excised GSV. Methods One hundred nine GSV in 85 consecutive patients with clinical stage C 2-6 E P,S A S,P,D P R disease were treated with ELT. Twelve months of follow-up with duplex scanning at regular intervals was possible in 104 treated veins (95.4%) in 82 patients (96.5%). Recanalized vessels were removed surgically and examined at histopathology. Results ELT-induced occlusion proved permanent at duplex sc…
Structure-function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients.
2012
Purpose Flicker defined form perimetry (FDF) and frequency doubling technology perimetry (FDT) are alleged to detect glaucoma at an earlier stage than standard automated perimetry (SAP). It is the purpose of this study to investigate the structure-function relationship between FDF, FDT, SAP, and confocal scanning laser ophthalmoscopy (cSLO) in patients with glaucoma. Methods Seventy-six patients with glaucoma were included in the study. Patients were tested with SAP, Matrix-FDT, FDF perimetry, and cSLO. Structure-function relationships between global and sectoral cSLO parameters and global and sectoral mean sensitivity (MS) of SAP, Matrix-FDT, and FDF were calculated using Spearman's rank c…
Flicker Defined Form Perimetry in Glaucoma Suspects with Normal Achromatic Visual Fields
2014
To evaluate if repeated flicker-defined form (FDF) perimetry can detect visual field (VF) defects in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP).Patients with optic nerve heads (ONHs) or retinal nerve fiber layer (RNFL) findings clinically suspicious for glaucoma and normal SAP were enrolled. Patients underwent VF testing with FDF perimetry (Heidelberg Edge Perimetry, HEP) at two consecutive visits (HEP I and HEP II) and confocal scanning laser ophthalmoscopy with the Heidelberg Retina Tomograph (HRT). Abnormal HEP was defined by cluster-point analysis (CPA) and by the HEP specific glaucoma hemi-field test (GHT). Results were compared with an age-…
Sensitivity of laser-evoked potentials versus somatosensory evoked potentials in patients with multiple sclerosis
2003
Somatosensory evoked potentials (SEPs) play a less important role in the diagnosis of multiple sclerosis (MS) than visually evoked potentials. Since standard SEPs only reflect the dorsal column function, we now investigated spinothalamic tract function in patients with MS using laser-evoked potentials (LEPs).LEPs to thulium laser stimuli (3ms, 540 mJ, 5mm diameter) were recorded from 3 midline positions (Fz, Cz, Pz) in 20 patients with MS, and 6 patients with possible but unconfirmed MS. Peak latencies and peak-to-peak amplitude of the vertex potential negativity (N2) and positivity (P2) were evaluated and compared with normative values from 22 healthy control subjects. Median and tibial ne…
Histological differences in the adherence of connective tissue to laser-treated abutments and standard abutments for dental implants. An experimental…
2017
Background The goal of the current study is to assess the difference in connective tissue adherence to laser microtextured versus machined titanium abutments. Material and Methods Six patients were selected and each of them received 2 implants, one combined with a laser treated abutment and one with a machined abutment. After three months, the abutments were retrieved together with their surrounding gingival tissue for histological analysis. Qualitative and quantitative evaluation of microscopical images was performed to assess the presence or absence of adherence between the soft tissues and the abutment, and the percentage of soft tissue adhered to the two different surfaces. Results Inti…
Longitudinal analysis of taurine induced effects on the tear proteome of contact lens wearers and dry eye patients using a RP-RP-Capillary-HPLC-MALDI…
2012
Tear proteomic studies revealed distinct similarities between contact lens wearers and dry eye patients. AMO Complete® multipurpose contact lens cleaning solutions containing taurine seem to have a beneficial effect regarding contact lens induced dry eye. To illuminate the effect of taurine on the tear proteome of contact lens wearers and sicca patients we developed a gel-based RP-RP capillary HPLC-MALDI TOF/TOF MS strategy. Two contact lens wearer groups, one using eye drops containing 0.05% taurine; the other for control physiological NaCl solution were monitored. Also, a third group of sicca patients using taurine solution was studied (N=4 individuals/group). Tear pools of each group at …
Psychophysics, flare, and neurosecretory function in human pain models: capsaicin versus electrically evoked pain.
2007
Intradermal capsaicin injection (CAP) and electrical current stimulation (ES) are analyzed in respect to patterns and test-retest reliability of pain as well as sensory and neurosecretory changes. In 10 healthy subjects, 2 CAP (50 g) and 2 ES (5 to 30 mA) were applied to the volar forearm. The time period between 2 identical stimulations was about 4 months. Pain ratings, areas of mechanical hyperalgesia, and allodynia were assessed. The intensity of sensory changes was quantified by using quantitative sensory testing. Neurogenic flare was assessed by using laser Doppler imaging. Calcito- nin gene-related peptide (CGRP) release was quantified by dermal microdialysis in combination with an en…
Local Gingival Blood Flow at Healthy and Inflamed Sites Measured by Laser Doppler Flowmetry
2006
This investigation aimed to: 1) develop a method to obtain reproducible laser Doppler flow readings (LDFRs) at the gingiva of the maxillary front teeth; 2) evaluate regional gingival blood flow (GBF) in healthy gingiva by laser Doppler flowmetry; 3) compare hand-held LDFR (H-LDFR) with splint LDFR (S-LDFR); and 4) monitor changes in GBF in experimental gingivitis (EG) and chronic gingivitis (CG).The LDFR, gingival index (GI), and plaque index (PI) were measured at 13 gingival sites (teeth #6 to #11) in 10 healthy volunteers (five males and five females), 23 to 34 years of age, over a period of 12.5 +/- 3.27 days employing a partial-mouth EG model and in 11 patients (three males and eight fe…
Transcranial Doppler diagnosis of cerebral vasospasm following subarachnoid haemorrhage: correlation and analysis of results in relation to the age o…
1994
A retrospective analysis was undertaken to determine whether cerebral vasospasm following subarachnoid haemorrhage (SAH) correlates with the age of patients. For at least 3 weeks after bleeding 80 subjects underwent very close follow-up with clinical examination and transcranial Doppler records of the blood velocities within the basal cerebral arteries. Firstly a correlation between measured maximal mean blood flow velocities and age was made. Secondly, according to their age and the maximum of recorded mean velocities (v), the patients were divided into groups as follows: age 55 years or less, age more than 55 years; and maximum velocity v190 cm/s, 90 cm/sv2120 cm/s, 120 cm/sv3160 cm/s, v4…
Ranibizumab for Branch Retinal Vein Occlusion Associated Macular Edema Study (RABAMES): six-month results of a prospective randomized clinical trial
2014
Purpose To compare standard-of-care grid laser photocoagulation versus intravitreal ranibizumab (IVR) versus a combination of both in the treatment of chronic (>3 months) macular oedema secondary to branch retinal vein occlusion. Methods Prospective, randomized, multicentre clinical trial. Thirty patients with a best-corrected visual acuity (BCVA) between 20/320 and 20/40 were randomized 1:1:1 to receive grid laser or three monthly injections of 0.5 mg IVR or both followed by 3 months of observation. Results Mean change from baseline BCVA at month 6 was +2 letters [laser; 0.04 logMAR, 95% confidence interval (−0.17; 0.25)], +17 letters [IVR; 0.34 (0.19; 0.5)] and +6 letters [combination; 0.…