Search results for "lcsh:QC350-467"

showing 10 items of 35 documents

Objective Amplitude of Accommodation Computed from Optical Quality Metrics Applied to Wavefront Outcomes

2009

Purpose: We studied the accuracy and precision of 32 objective wavefront methods for finding the amplitude of accommodation obtained in 180 eyes. Methods: Ocular accommodation was stimulated with 0.5 D steps in target vergence spanning the full range of accommodation for each subject. Subjective monocular amplitude of accommodation was measured using two clinical methods, using negative lenses and with a custom Badal optometer. Results: Both subjective methods gave similar results. Results obtained from the Badal optometer where used to test the accuracy of the objective methods. All objective methods showed lower amplitude of accommodation that the subjective ones by an amount that varied …

Accuracy and precisionamplitude of accommodationgenetic structuresComputer scienceAcousticssubjective methods050105 experimental psychology03 medical and health sciencesimage quality metricsobjective methods0302 clinical medicinelcsh:Ophthalmologymedicineamplitud de acomodaciónlcsh:QC350-4670501 psychology and cognitive sciencesmétodos subjetivosSimulationWavefrontmétricas de calidad de imagenmétodos objetivos05 social sciencespresbiciaPresbyopiamedicine.diseaseOptical qualityAmplitude of accommodationlcsh:RE1-994030221 ophthalmology & optometrypresbyopiaOriginal Articlelcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Influence of different types of astigmatism on visual acuity

2016

[EN] Purpose To investigate the change in visual acuity (VA) produced by different types of astigmatism (on the basis of the refractive power and position of the principal meridians) on normal accommodating eyes. Methods The lens induced method was employed to simulate a set of 28 astigmatic blur conditions on different healthy emmetropic eyes. Additionally, 24 values of spherical defocus were also simulated on the same eyes for comparison. VA was measured in each case and the results, expressed in logMAR units, were represented against of the modulus of the dioptric power vector (blur strength). Results LogMAR VA varies in a linear fashion with increasing astigmatic blur, being the slope o…

AdultMaleVisual acuityVisual acuityAstigmatismoEstado de acomodaciónAstigmatismAgudeza visual03 medical and health sciences0302 clinical medicinelcsh:Ophthalmologymedicinelcsh:QC350-467HumansAgudeza visualAccommodation OcularAstigmatismmedicine.diseaseEyeglassesReadingEjelcsh:RE1-994Defecto esféricoFISICA APLICADA030221 ophthalmology & optometryOptometryAccommodation stateOriginal ArticleFemalemedicine.symptomSpherical defocusAxisPsychologylcsh:Optics. Light030217 neurology & neurosurgeryOptometry
researchProduct

Diseño de una nueva prueba para medir la función de sensibilidad al contraste con iPad

2015

[EN] Purpose: To introduce a new application (ClinicCSF) to measure Contrast Sensitivity Function (CSF) with tablet devices, and to compare it against the Functional Acuity Contrast Test (FACT). Methods: A total of 42 subjects were arranged in two groups of 21 individuals. Different versions of the ClinicCSF (.v1 and .v2) were used to measure the CSF of each group with the same iPad and the results were compared with those measured with the FACT. The agreements between ClinicCSF and FACT for spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) were represented by Bland---Altman plots. Results: Statistically significant differences in CSF of both groups were found due to the change…

AdultMalemedia_common.quotation_subjectVision DisordersVisual performanceFACTDesempeño visualCycles per degreeContrast SensitivityYoung Adultlcsh:OphthalmologyStatisticsHumansContrast (vision)lcsh:QC350-467Tablet devicesDiagnosis Computer-AssistedSensitivity (control systems)Simulationmedia_commonContrast sensitivity functionDispositivos de tabletaVision TestsMiddle AgedFunctional acuity contrast testConfidence intervalTest (assessment)Función de sensibilidad al contrasteiPadlcsh:RE1-994Computers HandheldFISICA APLICADAOriginal ArticleFemaleSpatial frequencyPsychologyEFAClcsh:Optics. LightOptometry
researchProduct

The effect of spherical aberration on visual performance and refractive state for stimuli and tasks typical of night viewing

2018

Purpose: The aim of this work was to examine the impact of Seidel spherical aberration (SA) on optimum refractive state for detecting and discriminating small bright lights on a dark background. Methods: An adaptive-optics system was used to correct ocular aberrations of cyclopleged eyes and then systematically introduce five levels of Seidel SA for a 7-mm diameter pupil: 0, ± 0.18, and ± 0.36 diopters (D) mm−2. For each level of SA, subjects were required to detect one or resolve two points of light (0.54 arc min diameter) on a dark background. Refractive error was measured by adjusting stimulus vergence to minimize detection and resolution thresholds. Two other novel focusing tasks for si…

AdultOptics and PhotonicsOriginal articleCorneal Wavefront AberrationVisual AcuityStarburstDiameter pupilRefraction Ocular050105 experimental psychology03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyError refractivoVisión nocturnaAberración esféricalcsh:QC350-467Humans0501 psychology and cognitive sciencesSpherical aberrationNight visionPhysicsResoluciónRefractive error05 social sciencesMiddle AgedRefractive ErrorsDetecciónDetectionlcsh:RE1-994030221 ophthalmology & optometryResolutionHumanitieslcsh:Optics. LightPhotic StimulationOptometryJournal of Optometry
researchProduct

Anthracene Fluorescence Quenching by a Tetrakis (Ketocarboxamide) Cavitand

2014

Quenching of both fluorescence lifetime and fluorescence intensity of anthracene was investigated in the presence of a newly derived tetrakis (ketocarboxamide) cavitand at various concentrations. Time-correlated single photon counting method was applied for the lifetime measurements. A clear correlation between the fluorescence lifetime of anthracene as a function of cavitand concentration in dimethylformamide solution was observed. The bimolecular collisional quenching constant was derived from the decrease of lifetime. Fluorescence intensity was measured in the emission wavelength region around 400 nm as a result of excitation at 280 nm. Effective quenching was observed in the presence of…

AnthraceneQuenching (fluorescence)Article SubjectChemistryAnalytical chemistryCavitandPhotochemistryseoksetFluorescenceAtomic and Molecular Physics and OpticsPhoton countingcarbon-tetrachlorideAnalytical Chemistrychemistry.chemical_compoundWavelengthlcsh:QC350-467Dimethylformamideta116stern-volmer plotslcsh:Optics. LightSpectroscopyExcitationJournal of Spectroscopy
researchProduct

Midinfrared FT-IR as a Tool for Monitoring Herbaceous Biomass Composition and Its Conversion to Furfural

2015

A semiquantitative analysis by means of midinfrared FT-IR spectroscopy was tuned for the simultaneous determination of cellulose, hemicellulose, and lignin in industrial crops such as giant reed (Arundo donaxL.) and switchgrass (Panicum virgatumL.). Ternary mixtures of pure cellulose, hemicellulose, and lignin were prepared and a direct correlation area/concentration was achieved for cellulose and lignin, whereas indirect correlations were found for hemicellulose quantification. Good correspondences between the values derived from our model and those reported in the literature or obtained according to the official Van Soest method were ascertained. Average contents of 40–45% of cellulose, 2…

Article SubjectbiologySpectroscopy; Analytical Chemistry; Atomic and Molecular Physics and OpticsArundo donaxSettore ING-IND/27 - Chimica Industriale E Tecnologicabiology.organism_classificationFurfuralAtomic and Molecular Physics and OpticsAnalytical Chemistrychemistry.chemical_compoundHydrolysischemistryAtomic and Molecular PhysicsYield (chemistry)Biomass characterization FTIR lignocellulose biomass pretreatmentlcsh:QC350-467Panicum virgatumLigninOrganic chemistryHemicelluloseand OpticsCelluloselcsh:Optics. LightSpectroscopyNuclear chemistryJournal of Spectroscopy
researchProduct

Investigation by raman spectroscopy of the decomposition process of HKUST-1 upon exposure to air

2016

We report an experimental investigation by Raman spectroscopy of the decomposition process of Metal-Organic Framework (MOF) HKUST-1 upon exposure to air moisture (T=300 K, 70% relative humidity). The data collected here are compared with the indications obtained from a model of the process of decomposition of this material proposed in literature. In agreement with that model, the reported Raman measurements indicate that for exposure times longer than 20 days relevant irreversible processes take place, which are related to the occurrence of the hydrolysis of Cu-O bonds. These processes induce small but detectable variations of the peak positions and intensities of the main Raman bands of th…

Atomic and Molecular Physics and OpticArticle SubjectAnalytical chemistry02 engineering and technology010402 general chemistry01 natural sciencesAnalytical Chemistrysymbols.namesakeRaman bandlcsh:QC350-467Relative humiditySpectroscopySpectroscopyMoistureChemistryChemical process of decomposition021001 nanoscience & nanotechnologyDecompositionAtomic and Molecular Physics and Optics0104 chemical sciencesScientific methodsymbols0210 nano-technologyRaman spectroscopylcsh:Optics. LightAnalytical Chemistry; Atomic and Molecular Physics and Optics; Spectroscopy
researchProduct

Tributo al professor Miguel F. Refojo, PhD, DSc (1928---2016)

2016

[Excerpt] July 21, 2016, Professor Miguel F. Refojo passed away at the age of 88 in Needham (Massachusetts). Saying that Miguel was one of the most renowned Spanish scientists of the second half of the XXth Century does not resembles its actual scientific size. Indeed, Miguel (or “Migüel” as most of his American friends pronounced his name) was a World Class scientist and inventor that will be forever linked to the advances in polymer science applied to the ophthalmic environment. His contributions in the biomedical field start “officially” in 1967 according to the National Library of Medline database (Pubmed-Medline). [...]

Ciências Naturais::Ciências Físicasmedia_common.quotation_subjectCorneal Diseases:Ciências Físicas [Ciências Naturais]Art historyHistorical ArticleTributeBiographyArt03 medical and health sciences0302 clinical medicinePortraitEditoriallcsh:Ophthalmologylcsh:RE1-994MAQUINAS Y MOTORES TERMICOS030221 ophthalmology & optometrylcsh:QC350-467lcsh:Optics. Light030217 neurology & neurosurgeryOptometrymedia_commonJournal of Optometry
researchProduct

Perfiles de potencia de las lentes de contacto medidas con NIMO TR1504

2017

This study was supported by the Ministerio de Economía y Competitividad and FEDER (Grant DPI2015-71256-R) and by the Generalitat Valenciana (Grant PROMETEOII-2014-072), Spain.

Contact LensesComputer sciencebusiness.industryRefraction OcularRefraction03 medical and health sciencesOcular physiology0302 clinical medicineOpticslcsh:Ophthalmologylcsh:RE1-994FISICA APLICADA030221 ophthalmology & optometryHumanslcsh:QC350-467businessScientific LetterAlgorithmsSoftware030217 neurology & neurosurgerylcsh:Optics. LightOptometry
researchProduct

Refractive changes in nuclear, cortical and posterior subcapsular cataracts. Effect of the type and grade

2015

Purpose: To determine the effect of main morphological types and grades of age-related cataracts on refractive error. Methods: We measured 276 subjects with optical compensation prior to the development of cataract. We evaluated 224 eyes with nuclear cataract, 125 with cortical cataract, and 103 with posterior subcapsular (PSC) cataract classified with LOCSIII. We measured visual acuity (VA) with their spectacles and best-corrected visual acuity (BCVA) with chart in decimal scale to obtain the optimal compensation with cataract. We evaluated the differences between compensations. Results: A significant myopic shift was observed in nuclear cataract from low to mild grade (p = 0.031), the sam…

Malemedicine.medical_specialtyRefractive errorNuclear cataractVisual acuitygenetic structuresCortical cataractVisual AcuityCatarataAstigmatismCataractContrast SensitivityCorticallcsh:OphthalmologyCataractsOphthalmologyLens CrystallineOptical compensationMyopiamedicineHumanslcsh:QC350-467Subcapsular posteriorNuclearIn patientCompensación ópticaAgedAged 80 and overAnalysis of Variancebusiness.industryAstigmatismLens Nucleus CrystallineLens Cortex CrystallineMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSurgeryPosterior subcapsularlcsh:RE1-994FemaleOriginal Articlesense organsPosterior subcapsular cataractmedicine.symptombusinesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct