Search results for "lcsh:Sports medicine"

showing 10 items of 113 documents

The Impact of the Progressive Efficiency Test on a Rowing Ergometer on White Blood Cells Distribution and Clinical Chemistry Changes in Paralympic Ro…

2017

Abstract There is a large gap in knowledge regarding research on post-exercise blood changes in disabled athletes. There are relatively few data on adaptive mechanisms to exercise in disabled athletes, including disabled rowers. Two rowers from a Polish adaptive rowing settle TAMix2x that qualified for the Paralympic Games in Rio, 2016 took part in this study. They performed a progressive test on a rowing ergometer until exhaustion. The cardiorespiratory fitness measures, complete blood count, white blood cells’ distribution and 30 clinical chemistry variables describing laboratory diagnostic profiles and general health were determined. The extreme effort induced changes in all studied meta…

disabled athletesRowingPhysiologyPhysical Therapy Sports Therapy and RehabilitationPhysical exercise030204 cardiovascular system & hematology03 medical and health scienceschemistry.chemical_compoundbiochemical markers0302 clinical medicineadaptive rowingSettore BIO/10 - BiochimicaPhysiology (medical)White blood cellSection IV – Behavioural Sciences in Sport - Adaptive SportsmedicineParalympic Gameslcsh:Sports medicineCreatininemedicine.diagnostic_testbiologyAthletesComplete blood countCardiorespiratory fitness030229 sport sciencesbiology.organism_classificationadaptive rowing biochemical markers disabled athletes Paralympic Games. IntroductionTest (assessment)medicine.anatomical_structurechemistrylcsh:RC1200-1245Journal of Human Kinetics
researchProduct

High-intensity endurance training increases nocturnal heart rate variability in sedentary participants

2015

The effects of endurance training on endurance performance characteristics and cardiac autonomic modulation during night sleep were investigated during two 4-week training periods. After the first 4-week training period (3 x 40 min per week, at 75% of HRR) the subjects were divided into HIGH group (n = 7), who performed three high-intensity endurance training sessions per week; and CONTROL group (n = 8) who did not change their training. An incremental treadmill test was performed before and after the two 4-week training periods. Furthermore, nocturnal RR-intervals were recorded after each training day. In the second 4-week training period HIGH group increased their VO2max (P = 0.005) more …

distance runningeducationheart rate variabilityEndurance performanceendurance performancelcsh:Biology (General)autonominen hermostoAutonomic nervous systemOriginal Articlelcsh:Sports medicinelcsh:RC1200-1245lcsh:QH301-705.5Distance runningHeart rate variability
researchProduct

 Running speed during training and percent body fat predict race time in recreational male marathoners

2012

 Background: Recent studies have shown that personal best marathon time is a strong predictor of race time in male ultramarathoners. We aimed to determine variables predictive of marathon race time in recreational male marathoners by using the same characteristics of anthropometry and training as used for ultramarathoners.Methods: Anthropometric and training characteristics of 126 recreational male marathoners were bivariately and multivariately related to marathon race times.Results: After multivariate regression, running speed of the training units (β=-0.52, P<0.0001) and percent body fat (β=0.27, P <0.0001) were the two variables most strongly cor…

educationlcsh:Sports medicinelcsh:RC1200-1245human activitiesOpen Access Journal of Sports Medicine
researchProduct

Development of an individualized familiarization method for vertical jumps

2013

OBJETIVO: Propor um método de familiarização individualizado para saltos verticais e verificar o seu efeito na variabilidade intrassujeito. MÉTODOS: Cinquenta e três homes (média ± DP; idade 23,5 ± 3,3 anos; estatura 1,76 ± 0,08 m; massa 72,8 ± 8,6 kg; percentual de gordura 12,9 ± 5,2%) realizaram sucessivos saltos até atingir o nível de estabilidade proposto. Após 48 h este processo era repetido e a estabilidade entre dias era verificada, se necessário, mais sessões eram realizadas. O nível de estabilidade foi determinado por um teste z, com intervalo de confiança de 95%. Após o processo de familiarização, duas sessões experimentais adicionais foram realizadas para determinar a confiabilid…

erro de mediçãoexercisebusiness.industryestudos metodológicosCoefficient of variationoutcome measurement errorsexercícioPhysical Therapy Sports Therapy and RehabilitationconfiabilidadeConfidence intervalStandard errorSquat jumpreliability of resultsmethodological studyCountermovement jumpPerformance monitoringOrthopedics and Sports Medicinelcsh:Sports medicineNuclear medicinebusinesslcsh:RC1200-1245MathematicsRevista Brasileira de Medicina do Esporte
researchProduct

Effect of the Game Design, the Goal Type and the Number of Players on Intensity of Play in Small-Sided Soccer Games in Youth Elite Players

2015

Abstract The aim of this study was to compare the effects of game design modification, the type of the goal and the number of players on the intensity of play in small-sided soccer games (SSGs) in youth elite players. Twenty young soccer players (age 13.7 ± 0.5 years, body mass 57.4 ± 7.8 kg, body height 1.67 ± 7.8 m, maximal heart rate 201.1 ± 8.2 beats/min) performed three types of SSGs (possession play (PP) vs. regular goals (RG) vs. small goals (SG)) in both four-a-side and six-a-side formats. The heart rate responses were recorded and analysed as an indicator of the intensity of play. The four-a-side format obtained higher intensity of play than six-a-side for PP (p<0.05), but not f…

footballMultimediaBody heightSection III – Sports TrainingPhysical Therapy Sports Therapy and Rehabilitationcomputer.software_genrePhysiological responsesfitnessIntensity (physics)Game designPhysiology (medical)Eliteaerobic performancelcsh:Sports medicinelcsh:RC1200-1245physiological responsescomputersoccer trainingResearch ArticleDemographyJournal of Human Kinetics
researchProduct

Heavy vs Light Load Single-Joint Exercise Performance with Different Rest Intervals

2017

Abstract The aim of the study was to compare the effect of three distinct rest period lengths between sets of upper body single-joint exercise with different load zones and volume designed for either endurance or hypertrophy (50% or 80% of 1-RM). Sixteen trained men (20.75 ± 2.54 years; 76.35 ± 5.03 kg; 176.75 ± 3.33 cm, 24.53 ± 1.47 kg/m2) performed a test and retest of 1-RM on non-consecutive days. Forty-eight hours after load testing, the participants were randomly assigned to six sessions consisting of four sets of the triceps pull-down, combining different intensities with distinct rest periods between sets. The shorter 1 minute rest promoted a significant reduction in the total repeti…

health promotionweight liftingPhysical fitnessPhysical Therapy Sports Therapy and Rehabilitation030204 cardiovascular system & hematologyPhysical strengthhealth promotion; muscular strength; physical fitness; weight lifting; Physical Therapy Sports Therapy and Rehabilitation; Physiology (medical)03 medical and health sciences0302 clinical medicineAnimal scienceAfterloadRest (finance)Physiology (medical)Exercise performanceLight loadSection III - Sports Traininglcsh:Sports medicineJoint (geology)Mathematicsbusiness.industryUpper body030229 sport sciencesphysical fitnephysical fitnesslcsh:RC1200-1245businessmuscular strength
researchProduct

Age of peak performance in elite male and female Ironman triathletes competing in Ironman Switzerland, a qualifier for the Ironman world championship…

2012

Christoph Alexander Rüst,1 Beat Knechtle,1,2 Patrizia Knechtle,2 Thomas Rosemann,1 Romuald Lepers31Institute of General Practice and for Health Services Research, University of Zurich, 2Gesundheitszentrum St Gallen, St Gallen, Switzerland; 3INSERM U1093, Faculty of Sport Sciences, University of Burgundy, Dijon, FranceBackground: The age of peak performance in elite endurance athletes has been investigated for elite marathoners, but not for elite Ironman triathletes. The aim of this study was to analyze the age of peak performance in swimming (3.8 km), cycling (180 km), running (42 km), and overall race time for elite female and male Ironman triathletes competing in Ironman Switzerl…

lcsh:Sports medicinelcsh:RC1200-1245Open Access Journal of Sports Medicine
researchProduct

Central European triathletes dominate Double Iron ultratriathlon – analysis of participation and performance 1985–2011

2012

Katrin Sigg,1 Beat Knechtle,1,2 Christoph Alexander Rüst,1 Patrizia Knechtle,2 Romuald Lepers,3 Thomas Rosemann11Institute of General Practice and Health Services Research, University of Zurich, Zurich; 2Gesundheitszentrum St Gallen, St Gallen, Switzerland; 3INSERM U1093, Faculty of Sport Sciences, University of Burgundy, Dijon, FranceBackground: A recent study showed that European triathletes performed faster in Double Iron ultratriathlons than North American athletes. The present study analyzed triathletes participating in Double Iron ultratriathlons to determine the origin of the fastest Double Iron ultratriathletes, focusing on European countries.Methods: Participation and perf…

lcsh:Sports medicinelcsh:RC1200-1245Open Access Journal of Sports Medicine
researchProduct

A comparison of medley and freestyle performance for national and international swimmers between 1994 and 2011

2013

Christof Buhl,1 Beat Knechtle,1,2 Christoph Alexander Rüst,1 Thomas Rosemann,1 Romuald Lepers31Institute of General Practice and for Health Services Research, University of Zurich, Zurich, Switzerland; 2Gesundheitszentrum St Gallen, St Gallen, Switzerland; 3Faculty of Sport Sciences, University of Burgundy, Dijon, FranceAbstract: The change in swim performance over time has been investigated for freestyle, but not for other strokes, such as in the medley. The aim of the study was to examine changes in 200 m and 400 m swim performances in medley swimmers at national (Switzerland) and international level (world championship finals) from 1994 to 2011. The 200 m and 400 m freestyle perform…

lcsh:Sports medicinelcsh:RC1200-1245Open Access Journal of Sports Medicine
researchProduct

Age and gender differences in half-Ironman triathlon performances – the Ironman 70.3 Switzerland from 2007 to 2010

2012

Beat Knechtle,1,2 Christoph Alexander Rüst,2 Thomas Rosemann,2 Romuald Lepers31Gesundheitszentrum St Gallen, St Gallen, Switzerland; 2Institute of General Practice and Health Services Research, University of Zurich, Zurich, Switzerland; 3INSERM U1093, Faculty of Sport Sciences, University of Burgundy, Dijon, FranceBackground: To date, the age-related decline and gender differences in performance have been investigated for both Olympic and Ironman distance triathlons, but not for the intermediate distance (ie, the half-Ironman distance triathlon covering 1.9 km swimming, 90 km cycling and 21.1 km running, Ironman 70.3®). We determined the age-related differences in performan…

lcsh:Sports medicinelcsh:RC1200-1245Open Access Journal of Sports Medicine
researchProduct