Search results for "leak"
showing 10 items of 244 documents
Importance and methodologies of endodontic microleakage studies: A systematic review
2017
Introduction It is very important to obtain a tight seal in obturated root canal, making it necessary to conduct clinical or laboratory studies on the sealability of endodontic materials. Different methodologies have been historically used to assess microleakage of different endodontic materials. The aim of the present study was to comprehensively review different material testing methods used in microleakage studies, their interpretation and importance in endodontic literature. Material and methods A systematic search was conducted in Medline, Cochrane, and Web of Science databases. In addition, the reference lists of review articles on the topic were searched. No language restriction was …
Microleakage in Class II composite restorations with margins below the CEJ: in vitro evaluation of different restorative techniques.
2012
Objectives: The purpose of this in vitro study was to evaluate the microleakage in "deep" Class II composite restorations with gingival cavosurface margin below the CEJ (cemento-enamel junction) and restored with different techniques. Study Design: Fifty human teeth were used. In each tooth two standardized Class II slot cavities (on mesial and on distal surfaces) were prepared: the buccolingual extension of the cavities was 4 mm; the gingival wall was located in dentin/cementum (2 mm beyond the CEJ). The prepared teeth were randomly assigned to 5 experimental groups (of 10 specimens and 20 cavities each) and restored. Group 1: Filtek TM Supreme XTE Flowable (3MESPE) + Universal Filtek Supr…
Marginal integrity of class V restorations: SEM versus dye penetration.
2006
To perform an in vitro investigation on the marginal integrity of different adhesives (Optibond FL, Scotchbond 1XT, Clearfil SE Bond, Adper Prompt L-Pop, S(3) Bond, iBond exp., Adper Prompt L-Pop) in combination with Tetric Ceram as well as an experimental silorane-restorative (Hermes, Hermes Bond; 3M ESPE) using SEM and dye penetration (2% methylene blue) in a comparative manner.Standardized class V-cavities (3 mm x 1.5 mm) were prepared in 70 extracted human teeth (n=10). The adhesives were applied according to manufacturers' instructions. The cavities were restored with three increments. After finishing and polishing (Sof-Lex discs) and thermocycling (5000x, 5/55 degrees C), replicas wer…
Marginal integrity of different resin-based composites for posterior teeth: an in vitro dye-penetration study on eight resin-composite and compomer-/…
2002
Abstract Objective: To determine improvements in marginal adaptation of resin-based composite restorative systems by means of flow-composites (Solitaire 2/Gluma Solid Bond, Solitaire 2/Flow Line/Gluma Solid Bond, Point 4/Optibond Solo Plus, Point 4/Revolution/Optibond Solo Plus) and to determine the equality of simplified bonding systems (Solitaire 2/Gluma Comfort Bond, Tetric Ceram/Tetric Flow/Excite, Dyract AP/Prime & Bond NT/NRC, Pertac II/Prompt-L-Pop) in marginal gap formation. Methods: The marginal dye penetration (2% methylene-blue) was investigated separately for the approximal boxes of Class II mod-cavities with one cervical margin of the approximal box within enamel, the other wit…
Sealing ability of five different retrograde filling materials.
1996
The sealing ability of Amalgam, Harvard-Cement, Diaket, gold-leaf, and Ketac-Endo as retrofilling materials was investigated. Paper cones were fixed with Harvard-Cement in the instrumented roots of 100 extracted human incisors. Apicectomy was performed and a 2-mm-deep retrograde cavity was prepared. Teeth were assigned to five groups (n = 20); each group received a different filling material. Surfaces of the roots were isolated with nail polish. Teeth, were stored in 1% methylene blue dye for 72 h. Roots were sectioned, and the depth of dye penetration was evaluated through a stereomicroscope. Retrofills with Ketac-Endo showed significantly less leakage compared with amalgam. There was no s…
Equivalent circuit analysis of solid-rotor induction machines with reference to turbocharger accelerator applications
2006
Theoretical, numerical and experimental studies are described that have been carried out to develop a solid-rotor induction machine design for a particularly demanding application as an accelerator drive for a diesel engine turbocharger. In this application the turbo-motor will be required to operate at speeds of up to 130 000 rpm and in temperatures that can exceed 200°C. The results show that the equivalent circuit gives predictions that are of sufficient precision for design purposes and provides a useful design tool. It is shown that the use of a solid rotor affects the value of the stator leakage reactance and influences the motor performance through this effect as well as by presentin…
A software for the evaluation of winding factor harmonic distribution in high efficiency electrical motors and generators
2013
In this paper a software developed for the determination of winding connections, the calculation of winding factors and the evaluation of their harmonic distribution of three and two phase windings is presented by using as input data simply the number of slots, pole pairs and phases. The software is implemented as a function in MATLAB environment. By means of some examples, covering the most relevant winding types, the capabilities of this software will be shown. Particularly, integer and fractional single and double layer winding can be treated. Some examples are presented and briefly discussed. The connections, the winding factor harmonic distribution, the electro-motive force (e.m.f) THD…
Performance Comparison of Electrical Motors equipped with slightly Asymmetrical Windings
2019
This paper presents a comparison between the performances of electrical machines equipped with slightly asymmetrical windings. More in detail, by modifying the stator geometry of an Interior Permanent Magnet Synchronous Machine equipped with a symmetrical winding configuration, other two slightly asymmetrical winding topologies are obtained. The three models are, then, analyzed by means of a finite element method (FEM) and the related results are compared in terms of cogging torque, static characteristics and leakage factor. The obtained results demonstrate that the adoption of slightly asymmetrical windings could be an interesting alternative solution during the design stage of electrical …
Sustained Late Branch Patency and Low Incidence of Persistent Type Ia Endoleaks Following Snorkel/chimney EVAR Shown in the Updated PERICLES Registry
2016
Leakage-detection in blade pitch control systems for wind turbines
2012
The main contribution of the work is a systematic study evaluating the performance of different filters for leakage detection in pitch control systems. The effectiveness of the proposed methods is examined in a Matlab/Simulink real-time environment. The test bed consists of the following elements: hydraulic power unit, servo valve, two leakage bypasses, hydraulic cylinder, payload and xPC-based control system. The filters are tested with the state-augmentation and the hypothesis testing approaches. To our knowledge, the comparison of these different approaches has not been done previously for this type of application. The paper concludes on the accuracy and sensitivity of the leakage detect…