Search results for "lens"

showing 10 items of 948 documents

Collagen copolymer posterior chamber phakic intraocular lens for hyperopia correction: three-year follow-up.

2013

Purpose To assess the efficacy, predictability, safety, and stability of the Visian V3 Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) for moderate to high hyperopia. Setting Private clinic, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, endothelial cell density, intraocular pressure (IOP), central vault, and adverse events were evaluated for 3 years postoperatively. Results The study comprised 73 eyes of 44 patients. The mean spherical equivalent decreased from +4.84 diopters (D) ± 1.6 (SD) (range +1.00 to +7.75 D) preoperatively to −0.13 ± 0.39 …

Adultmedicine.medical_specialtyIntraocular pressurePhakic Intraocular Lensesgenetic structuresVisual AcuitySpherical equivalentBiocompatible MaterialsCell CountRefraction OcularSafety indexCorneaYoung AdultLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreImplantable collamer lensEfficacy indexbusiness.industryEndothelium CornealMiddle Agedeye diseasesSensory SystemsPosterior chamber phakic intraocular lensEndothelial cell densityOphthalmologyHyperopiaTreatment OutcomeSurgerysense organsCollagenbusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.

2007

Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…

Adultmedicine.medical_specialtyPhakic Intraocular LensesMaterials scienceBiometrymedicine.medical_treatmentIrisIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinemedicineMyopiaHumansIris clawOptical path lengthbusiness.industryHigh myopiaAccommodation OcularAstigmatismGeneral MedicineMiddle AgedOphthalmologymedicine.anatomical_structureLens (anatomy)030221 ophthalmology & optometrybusinessAccommodation030217 neurology & neurosurgeryTomography Optical CoherenceCoherence (physics)Follow-Up StudiesEuropean journal of ophthalmology
researchProduct

Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.

2005

To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…

Adultmedicine.medical_specialtyVisual acuityBiometrymedicine.medical_treatmentLens Capsule CrystallineCapsular tension ringIntraocular lensCataract ExtractionGroup differencesLens Implantation IntraocularOphthalmologymedicineHumansCapsulorhexisShrinkageAgedAged 80 and overPhacoemulsificationbusiness.industryPhacoemulsificationEquipment DesignProstheses and ImplantsMiddle AgedSensory SystemsSurgeryOphthalmologyCapsular bagMicroscopy Electron ScanningSurgerymedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.

2004

Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…

Adultmedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectAstigmatismPhakic intraocular lensProsthesis DesignCycles per degreelaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineMyopiaContrast (vision)HumansPhakic iolIris clawDioptremedia_commonLenses Intraocularbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologySurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct

Age-associated oxidative damage leads to absence of γ-cystathionase in over 50% of rat lenses: Relevance in cataractogenesis

2004

Oxidative damage to lens proteins and glutathione depletion play a major role in the development of senile cataract. We previously found that a deficiency in gamma-cystathionase activity may be responsible for glutathione depletion in old lenses. The aims of this study were: (1) to investigate the mechanism that causes the age-related deficiency in gamma-cystathionase activity in the eye lens, and (2) to determine the role of gamma-cystathionase deficiency in cataractogenesis. Two populations of old rats were found, one (56%) whose lenses lacked gamma-cystathionase activity and the rest that exhibited detectable enzyme activity. gamma-Cystathionase protein was absent in lenses from old rats…

Agingmedicine.medical_specialtygenetic structuresGlycinemedicine.disease_causeBiochemistryCataractLens proteinchemistry.chemical_compoundPhysiology (medical)Internal medicineLens CrystallineGene expressionmedicineAnimalsRats WistarGlyceraldehyde 3-phosphate dehydrogenasechemistry.chemical_classificationbiologyCystathionine gamma-lyaseCystathionine gamma-LyaseGlutathioneGlutathioneeye diseasesEnzyme assayRatsOxidative StressEndocrinologyEnzymeBiochemistrychemistryAlkynesbiology.proteinsense organsOxidative stressFree Radical Biology and Medicine
researchProduct

Mujer, poder político y democracia paritaria. “Mujer y representación política institucional en la Comunidad Valenciana. 1977-1995. 2 parte.

2014

Mujer, poder político y democracia paritaria. “Mujer y representación política institucional en la Comunidad Valenciana. 1977-1995. 2 parte. En esta segunda parte se recogen las mujeres que han formado parte de la Administración Local (alcaldesas, diputadas provinciales y FVMP), en los sindicatos, asi como en otras instituciones: Consell Valencià de Cultura, Consejo de Radiotelevisión Valenciana, Sindicatura de Agravios, Academia Valenciana de la Lengua, universidades, direcciones de partidos políticos, y otras organizaciones de la Comunidad Valenciana. “Mujer y representación política institucional en la Comunidad Valenciana. 1977-1995. Diputadas, ministras y cargos institucionales” es la …

Alcaldesas de la Comunidad Valenciana. Clementina Rodenas Villena. Rita Barberá Nolla. Josefa Mateu. Rosa Mazón. Carmen Gimeno. María Cabanes. Vicenta Bosch Palanca. Josefa Mateu. Violeta Rivera. Rosa Mengual. Empar Navarro i Prosper. Celeste García Estarlich. Mª. Dolores Botella Arbona. Carmen Martínez Ramírez. Gloria Isabel Calero Albal. Francisca R. Viciano Guillem. Teresa Parra Almiñana. Vicenta Tortosa Urrea. Rosa Maria Verdú Ramos. Mª. Milagrosa Martínez Navarro. Ana Noguera. María Ángeles Crespo Martínez. María Emma Iranzo Martín. Amparo Belmonte Burgos. María Ángeles Crespo Martínez. Lina Insa Rico. Teresa Ballester Artigues. Elena María Bastidas Bono. Mª. Elena Albentosa Ruso. María Rosa Verdú Alonso. María José Torres Amorós. María José García Herrero. Antonia Martínez Soler. Mª del Carmen Martínez Clemor. Enriqueta Seller Roca de Togores. Juliana González Maillo. Mercedes Alonso García. Mª de los Frutos Barceló La Torre. Luisa Pastor Lillo. Mª Antonieta Carratalá Aracil. María del Carmen Jiménez Egea. María Milagros Diego Martínez. Ana María Kringe Sánchez. Josefa Martín Bru. Luisa Pastor Lillo. María Gloria Pérez Martínez. María Teresa Sempere Juan. María Teresa Carbonell Bernabeu. María Loreto Martínez Ramos. Alicia Vázquez Fernández. Carmen García-Fuster y González-Alegre. Encarna Lerma Blasco. Francisca Gimeno Mocholi.Concha Martínez Romero. María A. Crespo Martínez. Gloria Arnandis Boix. Rosa Isabel Ribes Abel. Margarita Pin Arboledas. Nuria Espí de Navas. Purificación Martí Fenollosa. Asunción Quinzá Alegre. María Consuelo Orias Gonzalvo. Ascensión Figueres Górriz. María Remedios Vila Castelló. Mª Luisa Oliver Mallasén. Herminia Palomar Pérez. María Teresa Sidro. Carmina Martinavarro Moya. Consuelo Sanz Molés. Concepción Saenz Laín. Gobernadora civil de Castellón. Carmen Moya García delegada del Gobierno en la Comunidad Valenciana. Carmen Mas Rubio delegada del Gobierno en la Comunidad Valenciana. Pilar Brabo. Dulce Contreras Isabel Segura Maria Antonia García Benau. Cristina Santamaría Siurana. Isabel Morant. Adela Cortina. Neus Campillo. Trinidad Simó. Remedios Sánchez entre otras. Irene Abad Miró. María Francisca Abad García. Mari Luz Terradas. Amparo Caballer Cabo.Foro de Opinión. María Dolores Vilanova Alonso. Amparo Llop. María José Reyes. Mariló Pla. Cristina Piris. Victoria Prades. Mari Luz Marco. Julia Carles. Elisa Cabanes. Magarita Sanz Alonso. Ofelia Vila Hernández. Carme Morenilla i Talens. Rosa Mª Magdalena Rodríguez Pérez. Rosa Serrano Llácer. Síndic de Greuges de la Comunidad Valenciana. Julia Sevilla Merino. Emilia Caballero Álvarez. Ascensión Figueres Górriz. Carmen Barceló Torres. Verónica Cantó Doménech. Maria Soledad González Felip. Amàlia Alba Tarazona. Dones Progressistes. Susana Camarero Benitez. Macarena Montesinos. Marcela Miró Pérez. Pepa Chesa. Mª Josep Amigó. Teresa Blat. Lobby Europeo de Mujeres. Rosa Solbes. Inmaculada Serra Yoldi.:CIENCIA POLÍTICA [UNESCO]UNESCO::CIENCIA POLÍTICA
researchProduct

Accommodative intraocular lenses: current status

2005

Purpose of review The possibility of using a monofocal IOL with accommodative ability allows refractive cataract surgery with a clearly decreased potential of photic phenomena. Three IOLs of different designs and materials have demonstrated accommodative ability, but the degree of accommodative amplitude has been reported to different extents and variabilities. The plate-haptic CrystaLens has a hinged design that might permit forward movement of the optic as a result of pressure changes in the vitreous cavity. The 1CU has modified haptics that bend in the bag as the lens capsule contracts, which are supposed to cause anterior displacement of the lens optic. With the dual-optic one-piece Syn…

Anterior lensgenetic structuresmedicine.medical_treatmentCataract ExtractionProsthesis Designlaw.inventionLens Implantation IntraocularlawmedicineHumansLenses IntraocularLens capsulebusiness.industryAccommodation OcularPresbyopiaGeneral MedicinePresbyopiaCataract surgerymedicine.diseaseeye diseasesLens (optics)OphthalmologyIntraocular lensesCapsular bagOptometrysense organsbusinessAccommodationCurrent Opinion in Ophthalmology
researchProduct

Effects of soyasaponin I and soyasaponins-rich extract on the Alternariol-induced cytotoxicity on Caco-2 cells

2015

Abstract Alternariol (AOH) is a mycotoxin produced by Alternaria spp. Soyasaponin I (Ss-I) is present naturally in legumes, and it has antioxidant properties. Cytotoxic and genotoxic effects of AOH have been demonstrated previously in vitro. In the present study, the cytotoxicity of AOH, Ss-I, and soyasaponins-rich extract from lentils was investigated; as well as, the cytoprotective effects of Ss-I and lentil extracts against AOH induced-cytotoxicity on Caco-2 cells. Cytotoxicity was carried out using MTT and PC assays (AOH: 3.125–100 µM, Ss-I: 3.125–50 µM, and lentil extracts: 1:0–1:32) during 24 h of exposure. Only AOH showed cytotoxic effect. The reduction in cell proliferation ranged f…

AntioxidantCell SurvivalStereochemistrymedicine.medical_treatmentAlternariolBiologyToxicologyAntioxidantsLactoneschemistry.chemical_compoundmedicineHumansCytotoxic T cellFood scienceOleanolic AcidCytotoxicityMycotoxinCell ProliferationPlant ExtractsCell growthAlternariaDrug SynergismGeneral MedicineMycotoxinsSaponinsIn vitrochemistryCytoprotectionCaco-2Lens PlantCaco-2 CellsDNA DamageFood ScienceFood and Chemical Toxicology
researchProduct

Comparative analysis of radical scavenging and antioxidant activity of phenolic compounds present in everyday use spice plants by means of spectropho…

2010

Comparative analysis of radical scavenging and antioxidant activities of phenolic compounds present in everyday use spice plants was carried out by means of spectrophotometric and chromatographic methods. Six spice plant samples, namely onion (Allium cepa), parsley (Petroselinum crispum) roots and leaves, celery (Apium graveolens) roots and leaves and leaves of dill (Anethum graveolens) were analyzed. Total amount of phenolic compounds and radical scavenging activity (RSA) was the highest in celery leaves and dill extracts and was the lowest in celery roots. Comparing commonly used spectrophotometric analysis of 2,2-diphenyl-1-picrylhydrazyl (DPPH) RSA of extracts with the results obtained …

AntioxidantDPPHmedicine.medical_treatmentFiltration and SeparationPharmacognosyPlant RootsHigh-performance liquid chromatographyAntioxidantsAnalytical Chemistrychemistry.chemical_compoundPhenolsOnionsElectrochemistrymedicinePhenolsSpicesChromatography High Pressure LiquidApiumChromatographybiologyChemistryAnethum graveolensApium graveolensFree Radical Scavengersbiology.organism_classificationPlant LeavesAlliumPetroselinumAnethum graveolensJournal of Separation Science
researchProduct

Comparison of two different devices to assess intraocular lenses

2016

[EN] In this paper, we have compared the performance of two commercial systems, Kaleo-I and IOLA Plus, in the characterization of monofocal intraocular lenses (IOLs) according to the International Standard requirements (ISO 11979-2). The dioptric power (DP) and the Modulation Transfer Function (MTF) at 100.1p/mm and 3.0 mm aperture have been measured with both instruments in twenty commercial monofocal HEMA IOLs and their agreement was assessed by Bland Altman analysis. Compared with the designed power, IOLA Plus gave lower values in 85% of measures: Kaleo I errors are dependent on the power of the lens: measurements were higher than the designed power in the low-medium power range and lowe…

Aperture01 natural scienceslaw.invention010309 optics03 medical and health sciencesMonofocal intraocular lens0302 clinical medicineOpticslawOptical transfer function0103 physical sciencesElectrical and Electronic EngineeringBland–Altman plotInternational standard and reliabilityMathematicsDioptric powerbusiness.industryModulation transfer functionAtomic and Molecular Physics and OpticsConfidence intervalElectronic Optical and Magnetic MaterialsLens (optics)Intraocular lensesFISICA APLICADA030221 ophthalmology & optometrybusiness
researchProduct