Search results for "lens"
showing 10 items of 948 documents
Perioperative pupil size in low-energy femtosecond laser-assisted cataract surgery
2020
Purpose To assess potential changes in pupil size during femtosecond laser-assisted cataract surgery (FLACS) using a low-energy laser system. Methods The pupil sizes of eyes undergoing FLACS were measured using the Ziemer LDV Z8 by extracting images from the laser software after each of the following steps: application of suction, lens fragmentation, and capsulotomy. Furthermore, the pupil diameters were measured based on preoperative surgical microscope images and after releasing the suction. Paired t-test and the two one-sided tests (TOST) procedure were used for statistical analyses. The horizontal and vertical pupil diameters were compared in each of the steps with preoperative values.…
Clinical spectrum of eye malformations in four patients with Mowat-Wilson syndrome
2015
Mowat-Wilson syndrome (MWS) is a rare genetic syndrome characterized by a specific facial gestalt, intellectual deficiency, Hirschsprung disease and multiple congenital anomalies. Heterozygous mutations or deletions in the zinc finger E-box-binding homeobox2 gene (ZEB2) cause MWS. ZEB2 encodes for Smad-interacting protein 1, a transcriptional co-repressor involved in TGF-beta and BMP pathways and is strongly expressed in early stages of development in mice. Eye abnormalities have rarely been described in patients with this syndrome. Herein, we describe four patients (two males and two females; mean age 7 years) with MWS and eye malformations. Ocular anomalies included, iris/retinal coloboma…
Series of fibrinous inflammation after implantation of capsular tension rings
2014
Purpose To analyze the cause of fibrinous inflammation in eyes with capsular tension rings (CTRs) after cataract surgery. Setting Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Mainz, Germany. Design Retrospective case series. Methods High-performance liquid chromatography was implemented to eliminate impurities. One CTR was explanted for microbiologic examination. The pH values of the CTR and the storage solution were analyzed, Seldi and Maldi tests were performed, as well as toxicity tests with immortal cell lines. Material batches were analyzed. The organic carbon content of CTRs, detergents, and storage solutions was checked. The presence of…
Effects of multipurpose contact lens solutions on the protein composition of the tear film
2005
Abstract Objectives: To analyze the influence of multipurpose contact lens cleaning solutions on tear proteins. Changes in tear film protein profiles of contact lens wearers who used several marketed brands of multipurpose contact lens care solutions, were assessed by ProteinChip analysis. Methods: Three studies were conducted. Study I was a comparison of Complete and OptiFree multipurpose solutions. Study II was a study with Complete Moisture Plus solution, Study II was a comparison of Renu and Solocare contact lens solutions. Wearers of soft contact lenses were assigned to use the contact lens care solutions for 4 weeks. Non-contact lens wearing patients were used as controls. Tear sample…
Visual and optical performance with the ReZoom multifocal intraocular lens
2011
Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…
Prospective visual evaluation of apodized diffractive intraocular lenses
2006
To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…
Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.
2011
PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…
Prospective study of the Acri.LISA bifocal intraocular lens
2007
To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…
Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation
2007
Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…
Sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsular rupture in cataract surgery.
2012
Purpose. To evaluate the safety of a foldable acrylic single-piece intraocular lens (IOL) in cases of complicated cataract surgery and sulcus implantation. The setting was University and private anterior segment surgery practices. Methods. In this observational case series study, 13 eyes of 13 patients were included after complicated phacoemulsification with extensive posterior capsule rupture with or without vitreous loss. A foldable acrylic single-piece IOL (Rayner Superflex 620H; Rayner Intraocular Lenses Limited, Hove, East Sussex, UK) was implanted in the ciliary sulcus in each eye. Postoperative follow-up included best-corrected visual acuity, anterior segment biomicroscopy, IOL centr…