Search results for "libration"
showing 10 items of 901 documents
Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory
2013
The Pierre Auger Observatory in Malargue, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18) eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, lo…
Measurement of the Cosmic Ray Helium Energy Spectrum from 70 GeV to 80 TeV with the DAMPE Space Mission
2021
The measurement of the energy spectrum of cosmic ray helium nuclei from 70 GeV to 80 TeV using 4.5 years of data recorded by the DArk Matter Particle Explorer (DAMPE) is reported in this work. A hardening of the spectrum is observed at an energy of about 1.3 TeV, similar to previous observations. In addition, a spectral softening at about 34 TeV is revealed for the first time with large statistics and well controlled systematic uncertainties, with an overall significance of $4.3\sigma$. The DAMPE spectral measurements of both cosmic protons and helium nuclei suggest a particle charge dependent softening energy, although with current uncertainties a dependence on the number of nucleons canno…
Observation of TeV gamma rays from the Cygnus region with the ARGO-YBJ experiment
2012
We report the observation of TeV gamma-rays from the Cygnus region using the ARGO-YBJ data collected from 2007 November to 2011 August. Several TeV sources are located in this region including the two bright extended MGRO J2019+37 and MGRO J2031+41. According to the Milagro data set, at 20 TeV MGRO J2019+37 is the most significant source apart from the Crab Nebula. No signal from MGRO J2019+37 is detected by the ARGO-YBJ experiment, and the derived flux upper limits at 90% confidence level for all the events above 600 GeV with medium energy of 3 TeV are lower than the Milagro flux, implying that the source might be variable and hard to be identified as a pulsar wind nebula. The only statist…
Coastal zone water quality: Calibration of a water-turbidity equation for MODIS data
2013
AbstractA nephelometric turbidity algorithm has been specifically calibrated for coastal waters in Sicily. To this purpose, intensive field campaigns were performed in July, August and September 2008. Measurements were collected in situ in three different gulfs. Statistical analysis suggests that field data should be spatially grouped but temporally separated; hence, new calibration parameters have been proposed.Turbidity retrieved by applying the algorithm using literature coefficients and the ones calibrated in situ are shown and compared. The comparison demonstrated that a specific calibration was necessary for quantitatively monitoring turbidity in Sicilian gulfs.
Multiyear in-situ measurements of atmospheric aerosol absorption properties at an urban coastal site in western Mediterranean
2016
Abstract In-situ aerosol absorption properties measured in Valencia (Spain) for four years, from February 2011 to February 2015, have been analysed. Spectral absorption properties have been obtained using a seven-wavelength Aethalometer AE-31 which covers the range from UV (370 nm) to IR (950 nm). In order to obtain the absorption coefficients, compensation parameters have been calculated for the Aethalometer considering seasonal and spectral differences. For this multiyear measurement period, seasonal site-specific calibration parameters have been obtained. Furthermore, estimations of the absorption Angstrom Exponent (α abs ) have been calculated using the seven Aethalometer wavelengths. T…
In search of traceability: two decades of calibrated Brewer UV measurements in Sodankylä and Jokioinen
2016
Abstract. The two Brewer spectrophotometers of the Finnish Meteorological Institute at Jokioinen and Sodankylä have been operated according to the highest levels of the WMO∕GAW (World Meteorological Organization∕Global Atmosphere Watch) recommendations with rigorous quality control and quality assurance. The calibration of the instruments is based on annual recalibrations of primary standard lamps in the VTT MIKES Metrology National Standards Laboratory in Finland and an exhaustive measurement program with measurements of standard and working lamps in the on-site optical laboratories. Over the years, the maintenance of the calibration has produced data sets of approximately 2000 lamp scans …
Intercomparison of spectroradiometers and Sun photometers for the determination of the aerosol optical depth during the VELETA-2002 field campaign
2006
In July 2002 the VELETA-2002 field campaign was held in Sierra Nevada (Granada) in the south of Spain. The main objectives of this field campaign were the study of the influence of elevation and atmospheric aerosols on measured UV radiation. In the first stage of the field campaign, a common calibration and intercomparison between Licor-1800 spectroradiometers and Cimel-318 Sun photometers was performed in order to assess the quality of the measurements from the whole campaign. The intercomparison of the Licor spectroradiometers showed, for both direct and global irradiances, that when the comparisons were restricted to the visible part of the spectrum the deviations were within the instrum…
Evaluation of the MOZAIC Capacitive Hygrometer during the airborne field study CIRRUS-III
2018
The MOZAIC Capacitive Hygrometer (MCH) is usually operated aboard passenger aircraft in the framework of MOZAIC (Measurement of Ozone by Airbus In-Service Aircraft) for measuring atmospheric relative humidity (RH). In order to evaluate the performance of the MCH, the instrument was operated aboard a Learjet 35A research aircraft as part of the CIRRUS-III field study together with a closed-cell Lyman-α fluorescence hygrometer (Fast in situ Stratospheric Hygrometer, or FISH) and an open-path tunable diode laser system (Open-path Jülich Stratospheric TDL ExpeRiment, or OJSTER) for water vapour measurement. After reducing the CIRRUS-III data set to data corresponding to MOZAIC aircraft operatio…
Operational considerations to improve total ozone measurements with a Microtops II ozone monitor
2012
A Microtops II "ozone monitor" with UV channels centered at 305.5, 312.5, and 320 nm has been used routinely in six experimental campaigns carried out in several geographic locations and seasons, covering latitudes from 35 to 68° N during the last ten years (2001–2011). The total ozone content is retrieved by Microtops II by using different combinations (Channel I, 305.5/312.5 nm; Channel II, 312.5/320 nm; and Channel III, 305.5/312.5/320 nm) of the signals at the three ultraviolet wavelengths. The long-term performance of the total ozone content determination has been studied taking into account the sensitivities to the calibration, airmass, temperature and aerosols. When a calibration was…
Intercomparison of spectroradiometers for global and direct solar irradiance in the visible range.
2003
This paper presents the results of the analysis of the spectral, global, and direct solar irradiance measurements in the visible range (400–700 nm) that were made in the framework of the first Iberian UV–visible (VIS) instruments intercomparison. The instruments used in this spectral range were four spectroradiometers: three Licor 1800s equipped with different receiver optics and one Optronic 754. For the direct solar irradiance measurements the spectroradiometers were equipped with collimators with different fields of view. Parallel studies have been carried out with the data given by the spectroradiometers with their original calibration file and with the same data that is corrected, foll…