Search results for "libration"
showing 10 items of 901 documents
Spatial diversity of chlorine residual in a drinking water distribution system: application of an integrated fuzzy logic technique
2014
A reduction in the concentration of chlorine, which is used as a chemical disinfectant for water in drinking water distribution systems, can be considered to be an index of the progressive deterioration of water quality. In this work, attention is given to the spatial distribution of the residual chlorine in drinking water distribution systems. The criterion for grouping the water-quality parameters normally used is highly subjective and often based on data that are not correctly identified. In this paper, a cluster analysis based on fuzzy logic is applied. The advantage of the proposed procedure is that it allows a user to identify (in an automatic way and without any specific assumption) …
The airborne mass spectrometer AIMS – Part 1: AIMS-H<sub>2</sub>O for UTLS water vapor measurements
2016
Abstract. In the upper troposphere and lower stratosphere (UTLS), the accurate quantification of low water vapor concentrations has presented a significant measurement challenge. The instrumental uncertainties are passed on to estimates of H2O transport, cloud formation and the role of H2O in the UTLS energy budget and resulting effects on surface temperatures. To address the uncertainty in UTLS H2O determination, the airborne mass spectrometer AIMS-H2O, with in-flight calibration, has been developed for fast and accurate airborne water vapor measurements. We present a new setup to measure water vapor by direct ionization of ambient air. Air is sampled via a backward facing inlet that inclu…
Validation of Landsat-7/ETM+ Thermal-Band Calibration and Atmospheric Correction With Ground-Based Measurements
2010
Ground-based measurements of land-surface temperature (LST) performed in a homogeneous site of rice crops close to Valencia, Spain, were used for the validation of the calibration and the atmospheric correction of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) thermal band. Atmospheric radiosondes were launched at the test site around the satellite overpasses. Field-emissivity measurements of the near-full-vegetated rice crops were also performed. Seven concurrences of Landsat-7 and ground data were obtained in July and August 2004-2007. The ground measurements were used with the MODTRAN-4 radiative transfer model to simulate at-sensor radiances and brightness temperatures, which were c…
Automatic cell nuclei counting: a protocol to acquire images and to compare results between color and multispectral images
2013
International audience; High-throughput screening in histology and analysis need a necessary automatic cell or nucleus counting. Current methods and systems based on grayscale or color images give results with counting errors. We suggest to use multispectral imaging (with more than three bands) rather than color one for nucleus counting. A traditional acquisition chains uses a source of white light and a CCD camera in addition to the optical microscope. To pass to a multispectral acquisition, we use a Programmable Light Source (PLS) in the place of the white light source. This PLS is capable of generating different wavelengths in the visible spectrum. So, one color image and four multispect…
Oscillatory Changes of the Heterogeneous Reactive Layer Detected with the Motional Resistance during the Galvanostatic Deposition of Copper in Sulfur…
2015
Metallic copper was galvanostatically deposited on quartz|gold resonant electrodes by applying a constant current in a 0.5 M CuSO4/0.1 M H2SO4 aqueous solution. Galvanostatic copper deposition is one of the best methodologies to calibrate the electrochemical quartz crystal microbalances (EQCM), a gravimetric sensor to evaluate changes in mass during the electrochemical reactions through the Sauerbrey equation. The simultaneous measurement of mass, current density, and motional resistance by an EQCM with motional resistance monitoring allows us to characterize the processes occurring on the electrode surface and at the interfacial regions with unprecedented detail. During the galvanostatic c…
Calibrating the Operational Beam Width and Maximum Range of a Ship Radar Used for Bird Observations
2010
In order to analyse quantitative radar observations of bird movements, one needs to know the dimensions of the air space surveyed by the radar. The present study shows how to calibrate the operational beam width and the maximum range of any radar for cross sections for different body sizes of songbirds. The trial used an X-band fan beam ship radar of 25 KW (Furuno Fr-2125) and a captive balloon. Metal spheres of different diameters, fastened to the bottom of the balloon at defined distances, corresponding to the radar cross sections of song birds, were moved in all three dimensions of the air space. Simultaneously to the location by radar, the position of the suspended sphere was measured b…
In-flight calibration of the ROSAT HRI ultraviolet sensitivity
2000
Comparing measured and estimated count rates of a few selected sample stars, we confirm the validity and provide the in-flight calibration of the ROSAT HRI UV/visible effective area model in Zombeck et al. The count rate estimates for Betelgeuse derived with this model are in agreement with the measured HRI upper limit. This result is also confirmed in an erratum by Berghöfer et al. aimed at revising their previous calculation, which was overestimated by more than 2 orders of magnitude. Adopting this ROSAT HRI UV/visible effective area model and measured UV/visible spectra of a set of sample stars covering the range of Teff 3000-40,000 K, we have built the calibration curves to estimate UV/…
Determination of phenytoin in plasma by molecularly imprinted solid-phase extraction.
2001
Abstract A molecularly imprinted polymer (MIP) using phenytoin as template and methacrylamide as the functional monomer was prepared. The selectivity was measured by comparing capacity factors of phenytoin and other structurally related compounds. The polymer was evaluated as a selective sorbent in molecularly imprinted solid-phase extraction (MISPE). Several washing solvents were tested to study their ability to disrupt the non-specific interactions occurring between the sample and the polymer matrix and the role of water in the recognition process was also investigated. It was shown that the key step of successful sample extraction is the right choice of the washing solvent. Plasma sample…
Determination of lectin-cell-binding parameters by a new agglutination technique.
1992
We applied a recently described technique which is based on a light transmission/scattering method to determine the association characteristics of the Geodia lectin to sheep erythrocytes. The agglutination assays were performed in a total volume of 3 ml with 5.4 x 10(6) erythrocytes/ml. At a concentration of 360 ng/ml 50% of the lectin molecules were bound to the cells within the first 10 s of incubation. Scatchard analyses revealed an association constant (K(a)) of 0.9 +/- 0.1 x 10(8) M-1 and a number of 3.8 +/- 0.6 x 10(6) lectin binding sites on one erythrocyte. The method was also successfully applied to determine quantitatively the inhibitory potential of sugars competing with cell sur…
Combination of supported liquid membrane and solid-phase extraction for sample pretreatment of triazine herbicides in juice prior to capillary electr…
2002
A possibility of a combination of supported liquid membrane (SLM) and solid-phase extraction (SPE) for the determination of atrazine at microgram level in different type of fruit juices is presented. In comparison to SPE extraction from juice samples, the application of SLM-SPE enrichment provides much cleaner extracts and the possibility of lowering the limit of detection as low as 30 microg/l. However, it was also shown that by appropriate manipulation of SLM extraction conditions mainly flow-rate of donor phase and volume ratio between donor and acceptor phase, the level of detection can be further decreased to 10 microg/l. The results suggest that the application of SLM extraction prior…