Search results for "libration"
showing 10 items of 901 documents
Assessing soil erosion in a small Sicilian basin by caesium-137 measurements and a simplified mass balance model
2000
Abstract The caesium-137 technique affords both an alternative to conventional measurement methods and an effective quantitative estimate of soil redistribution at the basin scale. Among the available calibration relationships which link the degree of increase or depletion of the 137Cs activity relative to the baseline 137Cs input and sediment yield, the mass balance approach has received increased application for its physical basis. First, the applicability of the refined simplified point-based mass balance (RSPMB) model of Zhang et al. (1999) at the scale of the morphological unit is proposed herein. The 137Cs spatial distribution measured in a small Sicilian basin and the spatial distrib…
Quantitative colorimetric-imaging analysis of nickel in iron meteorites.
2011
A quantitative analytical imaging approach for determining the nickel content of metallic meteorites is proposed. The approach uses a digital image of a series of standard solutions of the nickel-dimethylglyoxime coloured chelate and a meteorite sample solution subjected to the same treatment as the nickel standards for quantitation. The image is processed with suitable software to assign a colour-dependent numerical value (analytical signal) to each standard. Such a value is directly proportional to the analyte concentration, which facilitates construction of a calibration graph where the value for the unknown sample can be interpolated to calculate the nickel content of the meteorite. The…
Software for automated application of a reference-based method fora posterioridetermination of the effective radiographic imaging geometry
2005
Objectives: Presentation and validation of software developed for automated and accurate application of a reference-based algorithm (reference sphere method: RSM) inferring the effective imaging geometry from quantitative radiographic image analysis. Methods: The software uses modern pattern recognition and computer vision algorithms adapted for the particular application of automated detection of the reference sphere shadows (ellipses) with subpixel accuracy. It applies the RSM algorithm to the shadows detected, thereby providing threedimensional Cartesian coordinates of the spheres. If the three sphere centres do not lie on one line, they uniquely determine the imaging geometry. Accuracy …
Modelling spatial and spectral systematic noise patterns on CHRIS/PROBA hyperspectral data
2006
In addition to typical random noise, remote sensing hyperspectral images are generally affected by non-periodic partially deterministic disturbance patterns due to the image formation process and characterized by a high degree of spatial and spectral coherence. This paper presents a new technique that faces the problem of removing the spatial coherent noise known as vertical stripping (VS) usually found in images acquired by push-broom sensors, in particular for the Compact High Resolution Imaging Spectrometer (CHRIS). The correction is based on the hypothesis that the vertical disturbance presents higher spatial frequencies than the surface radiance. The proposed method introduces a way to…
Emission tomography with a large-hole collimator (CACAO): a possible new way to improve radionuclide imaging.
2002
This work aims to improve the quality of scintigraphy. It evaluates the use of a large-hole collimator, the Computer Aided Collimation Gamma Camera Project (CACAO), in SPECT. Acquisition data from the same object were simulated for CACAO and for a conventional collimator. Better signal-to-noise ratios were found for CACAO images, whatever the number of emitted photons. This work demonstrates that high-resolution images may be obtained with large-hole collimators. The combination of CACAO and pixilated detectors may further improve radionuclide imaging.
Studies of methods and tools for the really mixed visual coherence applied to the patrimony
2013
The work described in this report has as a target the mixed reality device ray-on, developed by the on-situ company. This device, dedicated to cultural heritage and specifically architectural heritage, is meant to be installed on-site and shows the user an uchronic view of its surroundings. As the chosen stance is to display photo-realistic images, two trails were followed: the improvement of the real-virtual merging by reproducing accurately the real lighting on the virtual objects, and the development of a real-time segmentation method which is resilient to lighting changes.Regarding lighting reproduction, an image-based rendering method is used in addition to a high dynamic range capture…
Temperature and emissivity separation from calibrated data of the Digital Airborne Imaging Spectrometer
2001
Abstract The Digital Airborne Imaging Spectrometer (DAIS), with six thermal infrared channels in the 8–14 μm window, was flown over the Barrax test site, Spain, in the framework of the DAIS Experiment in the summer of 1998. Atmospheric correction of the DAIS thermal channels was performed by means of local radiosonde measurements and a radiative transfer model. Ground measurements of temperature and emissivity for six selected spots (two bare soils, two water bodies, and two vegetated fields) were conducted with the objective of providing calibration and validation targets. Three targets were used for a linear ground calibration of the DAIS thermal channels. With the ground-calibrated image…
Wavefront holoscopy: application of digital in-line holography for the inspection of engraved marks in progressive addition lenses
2014
Progressive addition lenses (PALs) are engraved with permanent marks at standardized locations in order to guarantee correct centering and alignment throughout the manufacturing and mounting processes. Out of the production line, engraved marks provide useful information about the PAL as well as act as locator marks to re-ink again the removable marks. Even though those marks should be visible by simple visual inspection with the naked eye, engraving marks are often faint and weak, obscured by scratches, and partially occluded and difficult to recognize on tinted or antireflection-coated lenses. Here, we present an extremely simple optical device (named as wavefront holoscope) for visualiza…
Experimental calibration of flat jacks for in-situ testing of masonry
2018
Flat-jack testing method is one of the most commonly used techniques for the structural assessment of existing masonry structures. Single and double flat jacks are usually adopted to evaluate the acting normal stress, or the compressive behaviour of masonry material. Test procedures are codified by international standards (e.g., A.S.T.M D4729-87; C1196-04; C1197-04, R.I.L.E.M TC 177–MDT D.4; R.I.L.E.M. TC 177–MDT D.5), which provide the preliminary calibration of an experimental coefficient (km) and of the effective area (Aeff), which determination influences significantly the reliability of the test. This article presents the result of an experimental study on the calibration of flat jacks…
Calibration of in situ chlorophyll fluorometers for organic matter
2019
AbstractOrganic matter (OM) other than living phytoplankton is known to affect fluorometric in situ assessments of chlorophyll in lakes. For this reason, calibrating fluorometric measurements for OM error is important. In this study, chlorophyll (Chl) fluorescence was measured in situ in multiple Finnish lakes using two sondes equipped with Chl fluorometers (ex.470/em.650–700 nm). OM absorbance (A420) was measured from water samples, and one of the two sondes was also equipped with in situ fluorometer for OM (ex.350/em.430 nm). The sonde with Chl and OM fluorometers was also deployed continuously on an automated water quality monitoring station on Lake Konnevesi. For data from multiple lake…