Search results for "libration"

showing 10 items of 901 documents

Sequential injection analysis (SIA)-chemiluminescence determination of indomethacin using tris[(2,2'-bipyridyl)]ruthenium(III) as reagent and its app…

2006

Abstract Automated sequential injection (SIA) method for chemiluminescence (CL) determination of nonsteroidal anti-inflammatory drug indomethacin ( I ) was devised. The CL radiation was emitted in the reaction of I (dissolved in aqueous 50% v/v ethanol) with intermediate reagent tris(2,2′-bipyridyl)ruthenium(III) (Ru(bipy) 3 3+ ) in the presence of acetate. The Ru(bipy) 3 3+ was generated on-line in the SIA system by the oxidation of 0.5 mM tris(2,2′-bipyridyl)ruthenium(II) (Ru(bipy) 3 2+ ) with Ce(IV) ammonium sulphate in diluted sulphuric acid. The optimum sequence, concentrations, and aspirated volumes of reactant zones were: 15 mM Ce(IV) in 50 mM sulphuric acid 41 μL, 0.5 mM Ru(bipy) 3 …

IndomethacinAnalytical chemistrychemistry.chemical_elementBiochemistryDosage formAnalytical Chemistrylaw.inventionlawSpectrophotometrymedicineOrganometallic CompoundsEnvironmental ChemistrySpectroscopyChemiluminescenceDetection limitDosage FormsAqueous solutionmedicine.diagnostic_testMolecular StructureReproducibility of ResultsRutheniumStandard curvechemistryReagentCalibrationFlow Injection AnalysisLuminescent MeasurementsSolventsNuclear chemistryAnalytica chimica acta
researchProduct

Determination of phenolic antioxidants additives in industrial wastewater from polypropylene production using solid phase extraction with high-perfor…

2019

Abstract This paper describes a new method for the effective extraction of the residues of five synthetic phenolic antioxidants (AOs): Ditertbutylphenol (DTF), Irganox 1010, Irganox 1076, Ethanox 330 and Cyanox 1790, from industrial water produced during the polypropylene (PP) deodorization process. In the deordorization process, PP is stored in a column for an average time of four hours and exposed to nitrogen and water vapor to remove inflammable compounds which may generate atypical odors in the PP. The samples of interest were taken in the desorber, followed by cleansing and pre-concentration using modified styrene divinylbenzene polymer cartridges. Liquid chromatography was performed w…

Industrial WasteWastewater010402 general chemistryPolypropylenes01 natural sciencesBiochemistryHigh-performance liquid chromatographyAntioxidantsAnalytical ChemistryStyreneIndustrial wastewater treatmentchemistry.chemical_compoundPhenolsLimit of DetectionSolid phase extractionChromatography High Pressure LiquidDetection limitChromatographyChemistry010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Solid Phase ExtractionReproducibility of ResultsGeneral MedicineContaminationDivinylbenzene0104 chemical sciencesCalibrationWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Fourier transform infrared determination of CO 2 evolved from carbonate in carbonated apatites

2000

A quantitative method based on FTIR has been developed to determine carbonate in synthetic apatites. The method measures the evolved CO2 after reaction of 50 mg apatite with 2 mL of hydrochloric acid (0.5 M) in a reaction vessel, heated to 40 degrees C. The CO2 evolved was swept by a carrier of nitrogen to a laboratory-made infrared gas cell of 39 mm pathlength and 490 microL volume. The signals were recorded as a function of time and the areas of the chemigram peaks obtained from the measurements in the wavenumber range of 2,500-2,150 cm(-1), were interpolated using a calibration curve. The method can be used to study apatites with carbonate contents below 0.2% with a sampling frequency of…

InfraredCalibration curveCarbonatesAnalytical chemistryInfrared spectroscopyHydrochloric acidEquipment DesignCarbon DioxideBiochemistryApatitechemistry.chemical_compoundsymbols.namesakeFourier transformchemistryApatitesvisual_artSpectroscopy Fourier Transform Infraredvisual_art.visual_art_mediumsymbolsCarbonateFourier transform infrared spectroscopyFresenius' Journal of Analytical Chemistry
researchProduct

Evaluation of two oxygen analyzers by computerized data acquisition and processing

1986

Monitoring of inspired oxygen concentration during anesthesia with nitrous oxide is becoming accepted as essential. This type of monitoring demands accurate monitors that respond rapidly. We evaluated two such devices for their response patterns to rapid changes in oxygen concentration, a galvanic or "fuel cell" unit and a polarographic device. Data were stored after analog-to-digital conversion. The response patterns to stepwise changes in nitrous oxide and oxygen mixtures were recorded at flow rates ranging from 2 to 10 L/min. Both units responded accurately to all changes in the absolute oxygen concentration; the polarographic unit was, on average, twice as fast. Responsiveness to nitrou…

Inspired oxygen concentrationComputersNitrous OxideGeneral EngineeringAnalytical chemistrychemistry.chemical_elementResponse timeNitrous oxideAnesthesia GeneralCritical Care and Intensive Care MedicineOxygenVolumetric flow rateOxygenchemistry.chemical_compoundchemistryEvaluation Studies as TopicCalibrationGalvanic cellHumansLimiting oxygen concentrationMonitoring PhysiologicPolarographyJournal of Clinical Monitoring
researchProduct

Precision luminosity measurements at LHCb

2014

Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy $\sqrt{s}$. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for $\sqrt{s}$ = 2.76, 7 and 8 TeV (proton-proton collisions) and for $\sqrt{s_{NN}}$ = 5 TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves sig…

Instrumentation for particle accelerators and storage rings - high energy (linear acceleratorsHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)cluster finding[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Nuclear Experiment06.20.fbInstrumentationMathematical PhysicsQCPhysicsLuminosity (scattering theory)Large Hadron ColliderPattern recognition cluster finding calibration and fitting methodssynchrotrons)DetectorPattern recognition cluster finding calibration and fitting methodsComputer interfacecalibration and fitting methodsFísica nuclearTracking and position-sensitive detectorLHCParticle Physics - ExperimentParticle physics29.40.GxPattern recognition cluster finding calibration and fitting methods; Instrumentation for particle accelerators and storage rings - high energy (linear accelerators synchrotrons)Astrophysics::High Energy Astrophysical PhenomenaFOS: Physical sciencesAstrophysics::Cosmology and Extragalactic AstrophysicsLHCb - Abteilung HofmannPattern recognition cluster finding calibration and fitting methodInstrumentation for particle accelerators and storage rings - high energy (linear accelerators synchrotrons)NOConsistency (statistics)Pattern recognitionCalibrationSDG 7 - Affordable and Clean EnergyInstrumentation for particle accelerators and storage rings - high energy (linear accelerators synchrotrons)/dk/atira/pure/sustainabledevelopmentgoals/affordable_and_clean_energyInteraction pointStandards and calibrationFunction (mathematics)29.50.+vLHCbInstrumentation for particle accelerators and storage rings - high energy (linear accelerators synchrotrons); Pattern recognition cluster finding calibration and fitting methods; Instrumentation; Mathematical PhysicsTEVPhysics::Accelerator PhysicsHigh Energy Physics::ExperimentInstrumentation for particle accelerators and storage rings - high energy (linear accelerators synchrotrons); Pattern recognition cluster finding calibration and fitting methodsEnergy (signal processing)
researchProduct

Uncertainty Assessment of a Water-Quality Model for Ephemeral Rivers Using GLUE Analysis

2011

Every model is, by definition, a simplification of the system under investigation. Although it would be desirable to reduce the gap between the simulated and the observed behaviors of the system to zero, this reduction is generally impossible owing to the unavoidable uncertainties inherent in any modeling procedure. Uncertainty analyses can provide useful insights into the best model approach to be used for obtaining results with a high level of significance and reliability. The evaluation of parameter uncertainties is necessary for calibration and for estimating the impact of these uncertainties on model performance. In this context, the uncertainty of a river water-quality model developed…

Integrated urban drainage modeling Uncertainty assessment Model approaches Water-quality managementEnvironmental EngineeringSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleOperations researchCalibration (statistics)Context (language use)Data qualityEnvironmental ChemistryEnvironmental scienceSensitivity analysisBiochemical engineeringWater qualityGLUEUncertainty analysisReliability (statistics)General Environmental ScienceCivil and Structural EngineeringJournal of Environmental Engineering
researchProduct

Assessment of data availability influence on integrated urban drainage modelling uncertainty

2009

In urban water quality management, several models are connected and integrated for analysing the fate of pollutants from the sources in the urban catchment to the final recipient; classical problems connected with the selection and calibration of parameters are amplified by the complexity of the modelling approach increasing their uncertainty. The present paper aims at studying the influence of reductions in available data on the modelling response uncertainty with respect to the different integrated modelling outputs (both considering quantity and quality variables). At this scope, a parsimonious integrated home-made model has been used allowing for analysing the combinative effect of data…

Integrated urban drainage systemEnvironmental EngineeringQuality managementSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleOperations researchCalibration (statistics)Computer scienceEcological Modelingmedia_common.quotation_subjectSettore ICAR/02 - Costruzioni Idrauliche E Marittime E IdrologiaUncertainty analysiEnvironmental engineeringEnvironmental modellingModel reliability assessmentData pointDrainage system (geomorphology)Sensitivity analysisQuality (business)Receiving water bodySoftwareReliability (statistics)Uncertainty analysismedia_commonEnvironmental Modelling & Software
researchProduct

An intercalibration study of the use of 4-Methyumbelliferyl-ß-D-glucuronide for the specific enumeration of Escherichia coli in seawater and marine s…

1991

A fluorogenic assay for the specific detection of Escherichia coli on the basis of its β-glucuronidase activity (MUG method) was applied to seawater and marine sediments with different contamination levels. The study was carried out in three Mediterranean areas (Malaga-Spain, Nice-France and Palermo-Sicily), using strictly standardized methods (membrane filtration), media (mFC and Chapman-TTC agars) and reagents, to evaluate statistically its sensitivity and specificity according to the origin and contamination of samples, the workers performing the tests and the selected culture media. The results obtained indicate that the MUG method is highly specific (94.5%) and sensitive (90.8%) for th…

Intercalibration study 4-Methyumbelliferyl-ß-D-glucuronide Escherichia coliSettore MED/42 - Igiene Generale E Applicata
researchProduct

Application of an HPLC-MS/MS method for mycotoxin analysis in commercial baby foods

2012

Abstract This article describes the validation of an analytical method for the detection of 21 mycotoxins in baby food. The analytical method is based on the simultaneous extraction of selected mycotoxins by matrix solid-phase dispersion (MSPD) followed by liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) using a hybrid triple quadrupole-linear ion trap mass spectrometer (QTRAP®). Information Dependent Acquisition (IDA), an extra confirmation tool for samples that contain the selected mycotoxins, was used. The matrix effects were evaluated, and the corrections for the matrix effects were performed using two calibration approaches: external matrix-matched calibration and…

Internal standard calibrationChromatographyChemistryBaby foodExtraction (chemistry)food and beveragesGeneral MedicineMycotoxinsTandem mass spectrometryAnalytical ChemistryMatrix (chemical analysis)Baby foodchemistry.chemical_compoundMSPDCalibrationmedia_common.cataloged_instanceIon trapEuropean unionExternal matrix-matched calibrationMycotoxinQTRAPFood Sciencemedia_commonFood Chemistry
researchProduct

New method for remote and repeatable monitoring of intraocular pressure variations

2014

We present initial steps toward a new measurement device enabling high-precision, noncontact remote and repeatable monitoring of intraocular pressure (IOP)-based on an innovative measurement principle. Using only a camera and a laser source, the device measures IOP by tracking the secondary speckle pattern trajectories produced by the reflection of an illuminating laser beam from the iris or the sclera. The device was tested on rabbit eyes using two different methods to modify IOP: via an infusion bag and via mechanical pressure. In both cases, the eyes were stimulated with increasing and decreasing ramps of the IOP. As IOP variations changed the speckle distributions reflected back from th…

Intraocular pressuregenetic structuresComputer scienceLaser sourceBiomedical EngineeringDiagnostic Techniques Ophthalmologicallaw.inventionBiomaterialsSpeckle patternOpticslawmedicineCalibrationAnimalsIntraocular PressureMonitoring Physiologicbusiness.industryReproducibility of ResultsLasereye diseasesAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsScleramedicine.anatomical_structureMeasuring principleRemote Sensing TechnologyRabbitssense organsbusinessSensitivity (electronics)Journal of Biomedical Optics
researchProduct