Influence of the simultaneous calibration of multiple ring dosimeters on the individual absorbed dose

2021

Abstract Ring dosimeters for personal dosimetry are calibrated in accredited laboratories following ISO 4037-3 guidelines. The simultaneous irradiation of multiple dosimeters would save time, but has to be carefully studied, since the scattering conditions could change and influence the absorbed dose in nearby dosimeters. Monte Carlo simulations using PENELOPE-2014 were performed to explore the need to increase the uncertainty of H p 0 .07 in the simultaneous irradiation of three and five DXT-RAD 707H-2 (Thermo Scientific) ring dosimeters with beam qualities: N-30, N-80 and N-300. Results show that the absorbed dose in each dosimeter is compatible with each of the others and with the refere…

Materials scienceDosimeterRadiation Dosimetersbusiness.industryMonte Carlo methodPublic Health Environmental and Occupational HealthCoverage probabilityGeneral Medicine030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOptics030220 oncology & carcinogenesisAbsorbed doseCalibrationCalibrationDosimetryComputer SimulationIrradiationRadiometryCalibration ISO 4037 Monte Carlo Personal dosimetry Ring dosimetersbusinessMonte Carlo MethodWaste Management and DisposalBeam (structure)Journal of Radiological Protection
researchProduct

Design and evaluation of a HDR skin applicator with flattening filter

2008

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure t…

Materials scienceDosimeterbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomKermaOpticsIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct

Local Reinforcement Effect of a Strain Gauge Installation on Low Modulus Materials

2005

The reinforcement effect of electrical resistance strain gauges is well documented in the technical literature. In this paper the local reinforcement effect in tension is studied by using a simple theoretical model by considering a strain gauge mounted on a semi-infinite plate having the same width of the strain gauge and subjected to a uniaxial tension load. Neglecting the effect of the adhesive layer and considering the interface shear stress as an exponential distribution, the proposed model gives a closed-form solution. In detail, this model permits a simple formula to be obtained which allows the user to correct the local reinforcement effect provided that a proper calibration is perfo…

Materials scienceExponential distributionbusiness.industryTension (physics)Applied MathematicsMechanical EngineeringStructural engineeringElectrical resistance and conductanceMechanics of MaterialsModeling and SimulationShear stressCalibrationAdhesivebusinessReinforcementStrain gaugeThe Journal of Strain Analysis for Engineering Design
researchProduct

LABORATORY INSTRUMENTATION TO STUDY CHANGES OF ELECTRICAL CONDUCTIVITY OF ROCKS WITH CHANGES OF FREQUENCY, TEMPERATURE AND PRESSURE*

1983

A laboratory instrument was developed to investigate the electrical properties of rock samples with respect to changes of frequency, temperature and pressure. The instrument can be used to obtain general trends and typical values for geological media. It should be of particular interest in geothermal studies and research in the geophysical properties of rocks. The design intervals for quantities under investigation were 20–300°C, 10 5 -4 × 10 7 Pa and 5 × 10 −4 -10 3 Hz. Certain limitations exist on the simultaneous use of the highest values of temperature and pressure. The main features of the instrument are: analog electrical outputs recorded by an x-y recorder or observed on a scope with…

Materials scienceHydrogeologyInstrumentationGeneral EngineeringMineralogyPressure vesselTemperature and pressureGeophysicsGeochemistry and PetrologyElectrical resistivity and conductivityCalibrationGeotechnical engineeringInstrumentation (computer programming)Hydraulic machineryGeothermal gradientIgneous petrologyGeologyGeophysical Prospecting
researchProduct

Comparative evaluation of the swelling and degrees of cross-linking in three organic gel packings for SEC through some geometric parameters.

2003

Abstract The size exclusion chromatographic (SEC) behavior of five solvent/polymer systems in three organic column packings based on polystyrene/divinylbenzene (PS/DVB) copolymer, TSK-Gel H HR , μ-styragel and TSK-Gel H XL , has been compared. All the packings offer similar characteristics (pore size, particle size and efficiency) but some differences have been found when eluting the same systems. The different elution behavior observed in both polymeric gels has been analyzed in terms of their swelling and cross-linking degrees and of the fractal parameters. From the Universal Calibration plots, values of the chromatographic partition coefficient, K p , have been obtained and using some eq…

Materials scienceMacromolecular SubstancesSize-exclusion chromatographyBiophysicsAnalytical chemistryMolecular ConformationBiochemistryFractal dimensionchemistry.chemical_compoundMaterials TestingmedicineOrganic ChemicalsParticle SizeViscositySolvationDivinylbenzenePartition coefficientEquipment Failure AnalysisCross-Linking ReagentschemistryVolume fractionCalibrationChromatography GelParticle sizeSwellingmedicine.symptomGelsPorosityJournal of biochemical and biophysical methods
researchProduct

Investigation of matrix effects in 193nm laser ablation-inductively coupled plasma-mass spectrometry analysis using reference glasses of different tr…

2012

Abstract The degree of transparency of glasses, which depends on the Fe content, may influence the ablation behavior during laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis. To test possible matrix effects when using a 193 nm Nd:YAG laser, we have analyzed transparent and opaque NIST, BAM and USGS reference glasses. These reference materials are ideal for such investigations, because they are well characterized, most elements are homogeneously distributed at the micrometer scale, and their Fe content varies over a very large range, from 16 to 130,000 μg g− 1. Our measurements show that the fractionation factors of refractory and volatile lithophile elements, …

Materials scienceOpacityTrace elementAnalytical chemistryFractionationMass spectrometryLaserAtomic and Molecular Physics and OpticsAnalytical Chemistrylaw.inventionlawCalibrationNISTInstrumentationSpectroscopyRefractory (planetary science)Spectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Shot-by-shot frequency calibration of CARS spectra: Application to the measurement of the collisional line shift in oxygen

1996

A technique using a Fabry-Perot interferometer has been developed to calibrate high-resolution spectra obtained by Coherent Anti-Stokes Raman Spectroscopy (CARS). This technique was used to measure simultaneously the Raman frequency and the Raman signal at each laser shot. We demonstrate the accuracy of the method by measuring theQ(15) line shifts of molecular oxygen due to collisions with oxygen and water vapour.

Materials sciencePhysics and Astronomy (miscellaneous)business.industryAstrophysics::Instrumentation and Methods for AstrophysicsGeneral EngineeringPhysics::OpticsGeneral Physics and AstronomyLaserSpectral linelaw.inventionsymbols.namesakeInterferometryOpticsShot (pellet)lawsymbolsCalibrationPhysics::Atomic PhysicsCoherent anti-Stokes Raman spectroscopyRaman spectroscopybusinessLine (formation)Applied Physics B Laser and Optics
researchProduct

Direct determination by portable ED-XRF of mineral profile in cocoa powder samples

2019

Abstract The present study has exploited the rapidity of the analysis and the multi-elemental capability of the energy dispersive X- ray fluorescence (ED-XRF) technique for the mineral profile determination in cocoa powder. A fast, cheap and environmental sustainable method without reagent consumption or toxic waste generation has been proposed. The samples can be prepared in the form of pellets of 13 mm in diameter and 2–3 mm thickness. The different internal calibrations used by ED-XRF equipment did not provide accurate results when comparing the mineral profile with the concentration obtained by Inductively Couple Plasma Optical Emission Spectroscopy (ICP-OES) after microwave assisted di…

Materials scienceRelative standard deviationPellets01 natural sciencesAnalytical Chemistry0404 agricultural biotechnologyMicrowave assisted digestionLimit of DetectionCalibrationChocolateMicrowavesDetection limitCacaoMineralsMineralChromatography010401 analytical chemistrySpectrometry X-Ray Emission04 agricultural and veterinary sciencesGeneral Medicine040401 food science0104 chemical sciencesSpectrophotometryReagentInductively coupled plasma atomic emission spectroscopyFood ScienceFood Chemistry
researchProduct

Virtual machine concept applied to uncertainties estimation in instrumented indentation testing

2019

The basis of the virtual machine concept, which is commonly used in coordinate measuring machines, was implemented to determine more realistic uncertainties on the estimation of the elastic modulus obtained from nanoindentation tests. The methodology is based on a mathematical model applied to simulate the testing process and to evaluate the uncertainties through Monte Carlo simulations whose application depends on the studied system (instrument, material, scale, etc.). The methodology was applied to the study of fused silica (FQ) and steel samples tested in a nanoindentation system. The results revealed that the most relevant sources of uncertainty are related to the calibration procedure,…

Materials scienceScale (ratio)Basis (linear algebra)Mechanical EngineeringMonte Carlo methodProcess (computing)Mechanical engineering02 engineering and technologyNanoindentation021001 nanoscience & nanotechnologyCondensed Matter Physicscomputer.software_genre01 natural sciences010309 optics[SPI]Engineering Sciences [physics]Mechanics of MaterialsVirtual machine0103 physical sciencesCalibrationGeneral Materials Science0210 nano-technologycomputerElastic modulusComputingMilieux_MISCELLANEOUS
researchProduct

2015

Electrically detected magnetic resonance (EDMR) is a commonly used technique for the study of spin-dependent transport processes in semiconductor materials and electro-optical devices. Here, we present the design and implementation of a compact setup to measure EDMR, which is based on a commercially available benchtop electron paramagnetic resonance (EPR) spectrometer. The electrical detection part uses mostly off-the-shelf electrical components and is thus highly customizable. We present a characterization and calibration procedure for the instrument that allowed us to quantitatively reproduce results obtained on a silicon-based reference sample with a “large-scale” state-of-the-art instru…

Materials scienceSiliconSpectrometerbusiness.industrySemiconductor device fabricationAnalytical chemistryGeneral Physics and Astronomychemistry.chemical_elementCharacterization (materials science)law.inventionOrganic semiconductorchemistryHardware_GENERALlawvisual_artElectronic componentvisual_art.visual_art_mediumCalibrationOptoelectronicsbusinessElectron paramagnetic resonanceAIP Advances
researchProduct