Search results for "libration"
showing 10 items of 901 documents
Mathematical Modeling and Optimization of a Vehicle Crash Test based on a Single-Mass
2014
In this paper mathematical modelling of a vehicle crash test based on a single mass is studied. The models under consideration consist of a single mass, a spring and/or a damper. They are constructed according to the measured vehicle speed before the collision and measured vehicle accelerations in three directions at the centre of gravity. A new model of nonlinear spring-mass-damper is also proposed to describe the crash. Simulation results are provided to show the effectiveness and applicability of the proposed methods.
Determination of mass attenuation coefficient by numerical absorption calibration with Monte-Carlo simulations at 59.54 keV
2016
Abstract This study presents a numerical method in order to determine the mass attenuation coefficient of a sample with an unknown chemical composition at low energy. It is compared with two experimental methods: a graphic method and a transmission method. The method proposes to realise a numerical absorption calibration curve to process experimental results. Demineralised water with known mass attenuation coefficient ( 0.2066 cm 2 g − 1 at 59.54 keV) is chosen to confirm the method. 0.1964 ± 0.0350 cm 2 g − 1 is the average value determined by the numerical method, that is to say less than 5% relative deviation compared to more than 47% for the experimental methods.
Measurement of the neutrino-oxygen neutral-current interaction cross section by observing nuclear deexcitation gamma rays
2014
We report the first measurement of the neutrino-oxygen neutral-current quasielastic (NCQE) cross section. It is obtained by observing nuclear deexcitation $\gamma$-rays which follow neutrino-oxygen interactions at the Super-Kamiokande water Cherenkov detector. We use T2K data corresponding to $3.01 \times 10^{20}$ protons on target. By selecting only events during the T2K beam window and with well-reconstructed vertices in the fiducial volume, the large background rate from natural radioactivity is dramatically reduced. We observe 43 events in the $4-30$ MeV reconstructed energy window, compared with an expectation of 51.0, which includes an estimated 16.2 background events. The background …
Neutron–gamma mixed field measurements by means of MCP–TLD600 dosimeter pair
2007
Abstract In this paper, we compared the TL response of three types of thermoluminescence dosimeters, TLD600 (6LiF:Mg,Ti), TLD700 (7LiF:Mg,Ti) and MCP (LiF:Mg,Cu,P) after exposure to a n–γ mixed field in the fluence range of radiotherapeutic applications. Since a dosimeter pair is required to discriminate the two components of the mixed field, we analyzed the ability of each dosimeter pair to provide the fluence value in the mixed field. At this aim we performed a 60Co–γ calibration and a neutron calibration for all three dosimeter types. Finally, a blind test was performed in order to analyze the accuracy of each dosimeter pair and we found that in this mixed field the fluence value obtaine…
From the Reference SEU Monitor to the Technology Demonstration Module On-Board PROBA-II
2008
The reference SEU Monitor system designed and presented in 2005 (R. H. SOslashrensen, F.-X. Guerre, and A. Roseng ldquoDesign, testing and calibration of a reference SEU monitor system,rdquo in Proc. RADECS, 2005, pp. B3-1-B3-7) has now been used by many researchers at many radiation test sites and has provided valuable calibration data in support of numerous projects. As some of these findings and results give new insight into improved inter-facility calibrations and provide additional inputs into ongoing SEE research, a few of the more interesting cases are presented. Furthermore the dasiadetector elementpsila, the Atmel AT60142F SRAM, now in a hybrid configuration, will form the key dete…
Upgrades to the collinear laser spectroscopy experiment at the IGISOL
2020
Abstract We give an overview of recent changes to the collinear laser spectroscopy beamline in the IGISOL laboratory. We present a new data acquisition system, commissioning of a newly installed charge exchange cell, and cooler-voltage calibration measurements. Currently ongoing modifications to the RFQ cooler-buncher are also discussed.
Well GeHP detector calibration for environmental measurements using reference materials
2016
International audience; A well-type detector installed in the Modane underground Laboratory (LSM) can combine both low background and high detection efficiency and it is well suited for the analysis of small amounts of environmental samples. Reference materials such as IAEA-447 (moss-soil), IAEA-RG-Th1 and IAEA-RG-U1 were used for the detector calibration, owing to a chemical composition close to those of the environmental samples. Nevertheless , the matrix effects and the true coincidence summing effects must be corrected from the full energy peak efficiency (FEPE). The FEPE was performed for a wide range of energy by a semi-empirical method using Monte Carlo simulation (MCNP6), intended f…
Study of the response of the ATLAS central calorimeter to pions of energies from 3 to 9 GeV
2009
Çetin, Serkant Ali (Dogus Author) A fully instrumented slice of the ATLAS central detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the response of the central calorimeters to pions with energies in the range between 3 and 9 GeV is presented. The linearity and the resolution of the combined calorimetry (electromagnetic and hadronic calorimeters) was measured and compared to the prediction of a detector simulation program using the toolkit Geant 4.
Study of energy response and resolution of the ATLAS barrel calorimeter to hadrons of energies from 20 to 350 GeV
2010
A fully instrumented slice of the ATLAS detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the results of the measurements of the response of the barrel calorimeter to hadrons with energies in the range 20 to 350 GeV and beam impact points and angles corresponding to pseudorapidity values in the range 0.2-0.65 are reported. The results are compared to the predictions of a simulation program using the Geant 4 toolkit.
The ANTARES Optical Beacon System
2007
ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirabl…