Search results for "lipids"
showing 10 items of 2228 documents
Surprising solvent-induced structural rearrangements in large [N···I
2018
Ion-mobility mass spectrometry and DFT calculations reveal the surprisingly solvent-dependent formation of large pentameric [N···I+···N] halogen-bonded capsules.
Domain formation in monolayers
1995
For phospholipids at the air/water interface we demonstrate that molecular chirality in some, but not in all, cases influences the domain shapes. In other cases chirality in the head group region can cause a chiral structure considering the tail arrangement. This indicates head group ordering. Minute changes of the molecular structure may change domain morphology from circular to dendritic. This can be related to slight changes of the lattice structure. In case of a dendritic domain the chains are more tilted, the deviation from hexagonal symmetry is more pronounced, and hence the lattice anisotropy is larger. This can be understood also in view of recent simulations considering diffusion-l…
Influence of Ge doping level on the EPR signal of Ge(1), Ge(2) and E'Ge defects in Ge-doped silica
2011
Abstract We present an experimental investigation on the Ge doping level dependence of the Electron Paramagnetic Resonance (EPR) signal spectral features of the Ge(1), Ge(2) and E'Ge defects induced in Ge doped silica. We have studied samples produced by sol–gel or PCVD techniques and doped with different amounts of Ge up to 20% by weight. The samples were gamma or beta ray irradiated and successively they were thermally treated to isolate the EPR signals of the different point defects. The data show that the EPR line shapes of the Ge(1) and the Ge(2) centers are progressively modified for doping level higher than 1%, whereas the line shape of the E'Ge defect appears independent from the do…
Validation of a method for neutron dosimetry and spectrometry using neutron activation of metal discs
2009
A technique for neutron dosimetry and spectrometry based on neutron activation of different metal discs has been studied. After exposure to a neutron field, the radionuclides produced in the discs are detected using low-level gamma-ray spectrometry and the neutron spectrum is obtained using a spectrum unfolding technique. In order to validate the method, irradiation was performed in a well-characterised (252)Cf neutron reference field. Furthermore, the detector was used to determine the neutron fluence rate and spectrum at a storage place for MOX nuclear fuel. The results of the two measurements are reported and discussed.
Alanine blends for ESR measurements of thermal neutron fluence in a mixed radiation field
2007
In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known…
Thermal Properties, Raman Spectroscopy and Tem Images of Neutron-Bombarded Graphite
2013
Neutron-irradiated graphite to a total dose of 3.6 × 1016 n cm−2 was studied by DSC, Raman spectroscopy and transmission electron microscopy (TEM). The Wigner energy of neutron-irradiated graphite was 9.5 J/g as measured by DSC; it was released with an exothermal peak at 220°C. The Raman spectroscopy has confirmed the expected effect caused by neutron irradiation of the graphite substrate. The TEM imaging has shown that neutron-irradiated graphite can be effectively exfoliated by sonication in comparison to pristine graphite, which under similar conditions does not exfoliate at all. The interstitial Frenkel defects in neutron-irradiated graphite are intercalated between the graphene layers …
"Table 4" of "Spectra and correlations of Lambda and Lambda produced in 340-GeV/c Sigma -+C and 260-GeV/c n+C interactions"
2002
Total inclusive LAMBDA LAMBDA pair production cross sections for the Neutron beam on the Carbon target.
"Table 2" of "Spectra and correlations of Lambda and Lambda produced in 340-GeV/c Sigma -+C and 260-GeV/c n+C interactions"
2002
Total inclusive LAMBDA and LAMBDABAR production cross sections for the Neutron beam on the Carbon target.
A measurement of the neutron to 199Hg magnetic moment ratio
2014
The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result γn/γHg=3.8424574(30).
Low-Intensity Neutron Emission from TiDx Samples Under Nonequilibrium Conditions
2001
Several experiments were performed that loaded titanium samples with deuterium from the gas phase, changed the temperature of the samples over a wide range, and monitored the neutron emission. Neutron emissions in very low intensity bursts, still significantly above the background, were recorded, revealing that low-energy nuclear reactions in condensed matter can be produced at a very low rate, which occasionally can be high enough to become detectable.