Search results for "liquid"

showing 10 items of 4351 documents

1985

Etude des phases isotrope, nematique et smectique de melanges de polymeres protones et en partie deuteries

chemistry.chemical_classificationCrystallographyDeuteriumChemistryLiquid crystallineLiquid crystalPolymerNeutron scatteringDie Makromolekulare Chemie, Rapid Communications
researchProduct

1978

chemistry.chemical_classificationCrystallographyMaterials sciencechemistryChemical engineeringLiquid crystallinePolymer chemistryPolymerDie Makromolekulare Chemie
researchProduct

Langmuir-Blodgett Mono- and Multilayer Assemblies of Amphiphilic Liquid- Crystalline n-Alkyl-4′-n-alkoxybiphenyl-4-carboxylates. I

1991

Five n-Alkyl-4′-Alkoxy-biphenyl-4-carboxylates were investigated as Langmuir monolayers at the air/ water interface and as Langmuir-Blodgett (LB) films on solid supports. All five compounds form stable monolayers at the air/water interface and can be transferred onto solid supports yielding LB-films, whose structures and kinetic behavior strongly depend on the headgroup. The structures of the LB-films were investigated by means of optical textures and X-ray diffraction and compared with the structures of the corresponding bulk phases which were investigated by means of Differential Scanning Calorimetry and X-ray powder diffraction. The LB-films of the acid and the two methyl esters exhibit …

chemistry.chemical_classificationCrystallographyMaterials sciencechemistryLiquid crystalGeneral Chemical EngineeringPhase (matter)BilayerMonolayerLamellar structureLangmuir–Blodgett filmPowder diffractionAlkylBerichte der Bunsengesellschaft für physikalische Chemie
researchProduct

1991

The sanidic polyamide [NM-Ph(CO 2 R) 3 (CO 2 Me)-NMCO-Ph(OR) 2 CO] n (R=C 12 H 25 ) is studied. It is shown that this polymer has a biaxial structure with quasi 2-D long range translational correlations. The correlations in one direction are limited by the length of the molecule. The oriented regions are separated by regions in which the molecules are less oriented

chemistry.chemical_classificationCrystallographyRange (particle radiation)High resolution electron microscopychemistrylawLiquid crystalPolyamideMoleculePolymerElectron microscopelaw.inventionDie Makromolekulare Chemie, Rapid Communications
researchProduct

Deuteron NMR Relaxation Studies of Combined Main-Chain/Side-Chain Polymers in the Liquid Crystalline and Glassy State

1989

Etude du polymere [O−Ph−CO 2 −Ph(R)−O−CO−Ph−O-(CH 2 ) 10 −] n (R=(CH 2 ) 6 −O−Ph−N=N−Ph−OMe) qui est caracterise par des parametres d'ordre des mesogenes de la chaine principale tres superieurs a ceux des chaines laterales. On observe une biaxialite moleculaire dans toutes les mesophases et dans la phase smectique A

chemistry.chemical_classificationCrystallographychemistryChain (algebraic topology)DeuteriumLiquid crystallineStereochemistryLiquid crystalGeneral Chemical EngineeringMolecular motionSide chainMoleculePolymerBerichte der Bunsengesellschaft für physikalische Chemie
researchProduct

Assays of Proteasome-Dependent Cleavage Products

2005

The degradation of misfolded, aged, or no longer needed cytosolic proteins depends largely on the ubiquitin-proteasome system. Proteasomes degrade their substrates into fragments of 3-20 amino acids. Human 20S proteasomes can be purified from human erythrocytes by batch adsorption to DEAE-cellulose, ammonium sulfate precipitation, anion-exchange fast protein liquid chromatography (FPLC), and glycerol density gradient ultracentrifugation. 20S proteasomes purified by this method are suitable for the in vitro digestion of synthetic peptides as well as full-length proteins. The degradation products produced by proteasomes are separated by reversed-phase HPLC using an acetonitrile gradient. The …

chemistry.chemical_classificationCytosolChromatographychemistryProteasomeEdman degradationFast protein liquid chromatographyDensity gradient ultracentrifugationHigh-performance liquid chromatographyAmmonium sulfate precipitationAmino acid
researchProduct

Method for evaluating the bioconversion of radioactive polyunsaturated fatty acids by use of reversed-phase liquid chromatography

1988

Abstract Reversed-phase high-performance liquid chromatography on a thermostatted octadecylsilyl column was used to separate mixtures of labelled polyunsaturated fatty acids (as their methyl esters) formed by successive desaturations and elongations of labelled linoleic (18:2 n - 6) or linolenic (18:3 n -3) acid by rat liver microsomes. Acetonitrile-water mixtures were used for elution of the esters. Unsaturated and saturated esters were detected by their refractive indices. The order of elution of fatty acid methyl esters in complex mixtures varies as a function of the chain length and unsaturation, analysis temperature, water concentration and solvent flow-rate. The peak areas vary as a f…

chemistry.chemical_classificationDegree of unsaturationChromatography GasChromatographyElutionChemistryOrganic ChemistryTemperatureFatty acidEstersGeneral MedicineReversed-phase chromatographyMetabolismFatty Acids NonesterifiedBiochemistryHigh-performance liquid chromatographyAnalytical ChemistrySolventsUnsaturated fatty acidChromatography LiquidPolyunsaturated fatty acidJournal of Chromatography A
researchProduct

In-tube solid-phase microextraction coupled by in valve mode to capillary LC-DAD: Improving detectability to multiresidue organic pollutants analysis…

2009

Abstract A simple and fast capillary chromatographic method has been developed to identify and quantify organic pollutants at sub-ppb levels in real water samples. The major groups of pesticides (organic halogens, organic phosphorous, and organic nitrogen compounds), some hydrocarbons (polycyclic aromatic hydrocarbons), phthalates and some phenols such as phenol and bisphenol A (endocrine disruptors) were included in this study. The procedure was based on coupling, in-tube solid-phase microextraction (IT-SPME) by using a conventional GC capillary column (95% methyl–5% phenyl substituted backbone, 80 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve to capillary liquid chromatog…

chemistry.chemical_classificationDetection limitChromatographyChemistryCapillary actionOrganic ChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographySolid-phase microextractionSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryHydrocarbonSeawaterSample preparationPolycyclic HydrocarbonsLasers SemiconductorOrganic ChemicalsSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Method for determination of formaldehyde in air in the pptv-range by HPLC after extraction as 2,4-dinitrophenyl-hydrazone

1982

The derivatization of formaldehyde with 2,4-dinitrophenylhydrazine and the extraction of the product formalhydrazone is studied. The determination is carried out by HPLC. Applying a cryogenic sampling technique and a sampling volume of 300l of air the detection limit of formaldehyde in air is 30 pptv and this is suitable for measurements of formaldehyde in the atmosphere. (IFU)

chemistry.chemical_classificationDetection limitChromatographyChemistryClinical BiochemistryExtraction (chemistry)FormaldehydeHydrazoneGeneral MedicineHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundGeneral Materials ScienceDinitrophenylDerivatizationFresenius' Zeitschrift für analytische Chemie
researchProduct

Determination of heavy metal complexes with humic substances by HPLC/ICP-MS coupling using on-line isotope dilution technique

1997

An isotope dilution mass spectrometric (IDMS) method has been developed for the simultaneous determination of the complexes of 11 heavy metals (Ag, Cd, Cu, Mo, Ni, Pb, Tl, U, W, Zn and Zr) with humic substances (HS) by coupling HPLC with ICP-MS and applying the on-line isotope dilution technique. The HPLC separation was carried out with size exclusion chromatography. This HPLC/ICP-IDMS method was applied to samples from a brown water, ground water, sewage and seepage water as well as for a sample containing isolated fulvic acids. The total contents of heavy metals and of their complexes were analyzed in these samples with detection limits in the range of 5–110 ng/L. The analysis of heavy me…

chemistry.chemical_classificationDetection limitChromatographySize-exclusion chromatographyIsotope dilutionMass spectrometryBiochemistryHigh-performance liquid chromatographyMetalchemistryvisual_artvisual_art.visual_art_mediumHumic acidWater pollutionFresenius' Journal of Analytical Chemistry
researchProduct