Search results for "loading"
showing 10 items of 233 documents
Angioid streak-related choroidal neovascularization treated by intravitreal ranibizumab.
2010
PURPOSE The purpose of this study was to report the visual outcome of intravitreal therapy with ranibizumab of choroidal neovascularization secondary to angioid streaks after 1-year follow-up. METHODS Nine patients (age, 58 +/- 4 years; range, 53-65 years) were treated with off-label intravitreal injections of 0.3 mg ranibizumab. Primary outcomes were best-corrected visual acuity changes (Early Treatment Diabetic Retinopathy Study logarithm of the minimum angle of resolution and letters) and optical coherence tomography macular thickness changes. RESULTS Mean follow-up was 14 months (+/-2; range, 12-18 months). Mean visual acuity was 0.52 logarithm of the minimum angle of resolution and 30 …
Effect of chamber characteristics, loading and analysis time on motility and kinetic variables analysed with the CASA-mot system in goat sperm.
2017
Several factors unrelated to the semen samples could be influencing in the sperm motility analysis. The aim of the present research was to study the effect of four chambers with different characteristics, namely; slide-coverslip, Spermtrack, ISAS D4C10, and ISAS D4C20 on the sperm motility. The filling procedure (drop or capillarity) and analysis time (0, 120 and 240s), depth of chamber (10 or 20μm) and field on motility variables were analysed by use of the CASA-mot system in goat sperm. Use of the drop-filling chambers resulted in greater values than capillarity-filling chambers for all sperm motility and kinetic variables, except for LIN (64.5% compared with 56.3% of motility for drop- a…
Effect of intramedullary gradual elongation of the shorter limb on gait patterns
2003
Background: Seven young patients were followed 52 weeks after intramedullary lengthening for limb length discrepancy (LLD). The mean LLD before surgery was 3.0 ± 1.1 cm and 1 year after surgery at the time of the nail-removal it was 0.3 ± 0.3 cm. Methods: The plantar pressures and the ground reaction forces (GRF) were recorded simultaneously with electromyographic (EMG) activities at normal and fast walking speeds. Results: Bilateral comparison indicated that the uncorrected LLD resulted in asymmetrical gait patterns. The peak pressures were higher in the lateral heel and in the medial forefoot in the longer limb as compared to the shorter limb at normal walking speed. At fast walking speed…
Usefulness of Clopidogrel Loading in Patients Who Underwent Transcatheter Aortic Valve Implantation (from the BRAVO-3 Randomized Trial)
2018
P2Y12-inhibitor initiation with clopidogrel using a loading dose (LD) versus no LD (NLD) provides more rapid inhibition of platelet activation and reduced risk of ischemic events after coronary stenting. Whether a similar beneficial effect is achieved in the setting of transcatheter aortic valve implantation (TAVI) is unknown. We evaluate the effects of preprocedural clopidogrel LD versus no NLD on 48-hour and 30-day clinical outcomes after TAVI. In the BRAVO-3 trial, 802 patients with severe aortic stenosis who underwent transfemoral TAVI were randomized to intraprocedural anticoagulation with bivalirudin or unfractionated heparin. Administration of clopidogrel LD was left to the discretio…
Complications of guided surgery and immediate loading in oral implantology: a report of 12 cases.
2011
Objectives: The growing interest in minimally invasive surgery, together with the possibility of fitting prostheses with immediate function, have led to the development of software capable of planning and manufacturing a surgical guide and prosthesis that can be placed upon conclusion of the implant surgery step. The present study evaluates the surgical and prosthetic complications of implant treatment with the guided surgery technique, together with patient comfort during and after treatment. Patients and methods: A retrospective observational study was made of 19 patients with partially or totally edentulous upper and/or lower maxillae, involving the placement of a total of 122 implants. …
Consumers’ neutralization strategies to counter normative pressure : The case of illegal downloading
2014
International audience; The process of neutralization of normative pressure by consumers, which allows the performance of deviant practices while maintaining the attachment to the norm, has not been sufficiently studied. Our analysis, in the case of illegal downloading, shows that consumers produce an autonomous discursive set, articulated around three defensive strategies (disempowerment as neutralizing, pragmatic neutralization, ideological neutralization) and accept internal contradiction.
Mechanical behavior of provisional implant prosthetic abutments
2014
Introduction: Implant-supported prostheses have to overcome a major difficulty presented by the morphology and esthetics of peri-implant tissues in the anterior sector. Diverse therapeutic techniques are used for managing the mucosa adjacent to the implant and the most noteworthy is immediate/deferred fixed provisionalization. Objectives: In vitro testing of strength and deformation of implant prosthetic abutments made from different materials (Titanium/PEEK/methacrylate). Material and Methods: Forty Sweden&Martina® implant prosthetic abutments (n=40) were divided into five groups: Group MP: methacrylate provisional abutments with machined titanium base; Group PP: Poly ether ether ketone (P…
Frictional effect in mode II delamination: Experimental test and numerical simulation
2013
Abstract The present paper proposes an experimental and a numerical analysis of the frictional effect on the mode II delamination. Frictional stresses between the crack edges can absorb and dissipate significant energy contributions in the delamination zones, especially under cyclic loading conditions. The experimental tests are performed for a set of unidirectional End-Notched Flexure (ENF) composite specimens, which are subjected to fatigue loading law with increasing mean value. The numerical analyses are performed considering a cohesive–frictional constitutive model, which is able to reproduce the transition of the interface behavior from the sound elastic condition to the fully cracked…
A strategy for the finite element modeling of FRP-confined concrete columns subjected to preload
2018
Abstract Compressive behavior of columns strengthened by means of an outer elastic confinement provided e.g. by fiber-reinforced polymer (FRP) jackets has become a main topic in the field of structural retrofitting. In details, the problem of the response assessment of strengthened columns is still under study. Many analytical formulations have been proposed to describe the compressive behavior of confined concrete under both monotonic and cyclic loads. However, the effect of a stress/strain level in the columns already present prior to apply the confinement has been generally neglected until now, also because of the lack of well defined strategies of modeling. In this frame, here, (1) a FE…
Effect of framework type on survival probability of implant-supported temporary crowns : an in vitro study
2020
Made available in DSpace on 2020-12-12T01:29:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-01-01 Background: This in vitro study evaluated the effect of framework type on the survival probability of temporary implant-supported crowns and on the implant platform structure after dynamic fatigue. Material and Methods: Thirty (30) external hexagon implants (3.75 x 10 mm) were embedded in acrylic resin following the ISO-14801. Standardized temporary crowns (n=10, N=30) were manufactured in acrylic resin and divided according to the framework type: Total plastic, Plastic with CoCr base and Titanium. The crowns were installed onto the implants (20N. cm) and fatigued (100N, 2 Hz) to det…