Search results for "locomotor"
showing 10 items of 153 documents
Estudio del efecto de los bifosfonatos (zoledronato) sobre la consolidación de las fracturas
2011
INTRODUCCIÓN La osteoporosis es una enfermedad sistémica crónica y progresiva que se caracteriza por una densidad ósea baja y por un deterioro de la micro-arquitectura del tejido óseo, que aumenta la probabilidad de sufrir una fractura ante mínimos traumatismos171. La incidencia de este tipo de fracturas es muy alta y además está en aumento151 debido al envejecimiento de la población. Dentro del tratamiento de la osteoporosis los bifosfonatos son los fármacos más utilizados al ser los que han demostrado mayor efectividad en la prevención de fracturas vertebrales, de cadera y periféricas19,87. Su principal efecto es la inhibición de la reabsorción ósea mediada por osteoclastos179. Dentro del…
Avoiding tunnel collisions between fibular collateral ligament and ACL posterolateral bundle reconstruction
2010
PURPOSE: The purpose of this study was to evaluate the risk of tunnel collisions of the fibular collateral ligament (FCL) and posterolateral bundle anterior cruciate ligament (PLB-ACL) tunnels during a combined FCL and double-dundle (DB) ACL reconstruction. METHODS: Thirty-six 4th-generation synthetic femurs (Sawbones, Pacific Research Laboratories, Vashon, WA) were utilized, and two different femur sizes were used. A FCL tunnel and a PLB-ACL tunnel were reamed on each femur. The tunnels of synthetic specimens that did not have a collision were filled with an epoxy resin augmented with BaSO(4) and radiographic evaluation, and Multidetector CT exams of the specimens were performed. RESULTS: …
How to avoid collision between PCL and MCL femoral tunnels during a simultaneous reconstruction.
2014
PURPOSE: The purpose of the present study was to assess the risk of femoral tunnel collisions between the medial collateral ligament (MCL) and the posterior cruciate ligament (PCL) tunnels during a simultaneous PCL and MCL reconstruction. METHODS: Fourth generation medium and large synthetic femur bones were used. On each femur, a MCL tunnel and a PCL tunnel were reamed. The MCL tunnel was drilled at 0°, 20° and 40° of axial and coronal angulations. The PCL femoral tunnel was reamed to simulate two different tunnel directions that could be obtained through an inside-out and outside-in technique. Tunnels were filled with epoxy resin augmented with BaSO4, and a multidetector CT examination of…
Nonunion of the carpal navicular: surgical treatment and PRP
2013
Attributes and definitions of locomotor capacity in older people: a World Health Organisation (WHO) locomotor capacity working group meeting report
2022
not available
Surgical time for graft preparation using different suture techniques
2016
Background: The purpose of the present study was to compare the operative time for graft prepa- ration using different techniques for graft sutur- ing. Material and methods: Flexor profundus tendons were harvested from fresh pig hind-leg trotters. Three different suture techniques were investigat- ed: the Krackow stitch (K), the Whipstitch (W), and the Modified Finger-Trap suture (MFT). Ten- dons were sutured starting at 10 mm from the dis- tal free end of the tendon. The suture configura- tions of the Krackow stitch and Whipstitch were completed with five suture throws. According to the MFT technique, the suture was wrapped five times around the tendon over a distance of 30 mm. The time re…
A rare case of peri-implant distal radius fracture☆
2021
A peri-implant fracture near the volar plate of distal radius represent a very rare injury. The main factor of this lesion is high energy trauma on the wrist. We report a case of a 61-year-old woman with a peri-implant fracture located just proximally to the plate and a fracture of the ulnar head that occurred after a simple fall. The patient was surgically treated by plate and screws removal. The fracture was fixed using a longer volar plate for the radial fracture and a plate for the head ulnar fracture. Different factors such as osteoporosis, BMI and screw position could influence the fracture pattern. However, considering growing use of plates for distal radius fracture fixation, the fr…
PRP in the treatment of Achilles tendinopaty
2013
Tibial tubercle osteotomy: effect of different osteotomy planes on contact surface area and tubercle anteriorization
2022
In 1983, Fulkerson introduced a technique of tibial tubercle osteotomy performed according to an inclined plane with respect to frontal plane. Due to obliquity of the osteotomy plane, this procedure allows both anterior and medial transfer of the tibial tubercle. The purpose of the study was to investigate the influence of the different degrees of the oblique plane of osteotomy on anterior displacement and the contact surface area of tibial tubercle. Synthetic bones were used for the study. An osteotomy of the tibial tubercle (TT) was performed in each specimen. Specifically, 3 different degrees of osteotomy planes relative to the reference frontal plane were examined: 20°, 30° and 40°. On …
Non-metallic implant for patellar fracture fixation: A systematic review
2016
Abstract Introduction Despite good clinical outcome proposals, there has been relatively little published regarding the use of non-metallic implant for patellar fracture fixation. The purpose of the study was to perform a systematic literature review to summarize and evaluate the clinical studies that described techniques for treating patella fractures using non-metallic implants. Methods A comprehensive literature search was systematically performed to evaluate all studies included in the literature until November 2015. The following search terms were used: patellar fracture, patella suture, patella absorbable, patella screw, patella cerclage. Two investigators independently reviewed all a…