Search results for "magnetometer"
showing 10 items of 102 documents
Eddy current imaging with an atomic radio-frequency magnetometer
2016
We use a radio-frequency $^{85}$Rb alkali-vapor cell magnetometer based on a paraffin-coated cell with long spin-coherence time and a small, low-inductance driving coil to create highly resolved conductivity maps of different objects. We resolve sub-mm features in conductive objects, we characterize the frequency response of our technique, and by operating at frequencies up to 250 kHz we are able to discriminate between differently conductive materials based on the induced response. The method is suited to cover a wide range of driving frequencies and can potentially be used for detecting non-metallic objects with low DC conductivity.
Tunable crossover between one- and three-dimensional magnetic dynamics inCoIIsingle-chain magnets organized by halogen bonding
2016
Low-temperature magnetometry, ac susceptibility, and calorimetry have been employed to study Co-based single-chain magnets (SCMs) organized through halogen bonding. Magnetic hysteresis and maxima in the dc and ac susceptibilities, respectively, confirm the SCM behavior of the system. Several characteristic magnetic relaxation regimes are observed at different temperatures, which can be associated with both intra- and interchain exchange interactions. Remarkably, tweaking the rate at which an external magnetic field is swept along the axis of the chains enables a controlled transition between the one- and three-dimensional dynamics. Experiments on an isostructural Co-based SCM system crystal…
Magnetization relaxation in YBCO films with improved supercurrent transport properties
2010
The relaxation of the irreversible magnetization in optimally doped YBCO films with natural and artificial pinning centres was measured in zero-field cooling conditions using SQUID magnetometry. The external magnetic field H was oriented along the c axis. An appropriate method for the determination of the characteristic vortex pinning energy from the normalized vortex-creep activation energy is discussed. This is based on the existence of a crossover elastic (collective) vortex creep at low temperatures T – plastic vortex creep at high T, caused by the T dependent macroscopic currents induced in the sample during magnetization measurements.
Feasibility study for a nanosatellite-based instrument for in-situ measurements of radio noise
2015
The radio environment on the earth is heavily affected by manmade sources such as radio transmissions, radars, and the like. The effect is particularly strong at MF frequencies and below, since the signals can propagate large distances via ionospheric bounce. Terrestrial magnetometer measurements have long been used to predict the Kp index, which is related to radio transmission at these ranges. Space weather measurements and models can also predict propagation of MF signals on the ground.
Magnetic and Structural Properties of Heusler Compounds with 27.8 Valence Electrons
2010
Co2-based Heusler compounds with 27.8 valence electrons exhibit an exceptional electronic structure that makes them interesting materials for the application in spintronics. Co2Cr0.6Fe0.4Al is the most prominent example of this particular family of compounds. In this article new materials of this class are tested with respect to their structural and magnetic properties. X-ray diffraction, Mossbauer spectroscopy, energy dispersive X-ray spectroscopy, and SQUID magnetometry were carried out to characterize the compounds. The use of Co2Fe0.45Ti0.55Ge as a new material in spintronic devices is suggested.
Sensitive magnetometry reveals inhomogeneities in charge storage and weak transient internal currents in Li-ion cells
2020
The ever-increasing demand for high-capacity rechargeable batteries highlights the need for sensitive and accurate diagnostic technology for determining the state of a cell, for identifying and localizing defects, and for sensing capacity loss mechanisms. Here, we leverage atomic magnetometry to map the weak induced magnetic fields around Li-ion battery cells in a magnetically shielded environment. The ability to rapidly measure cells nondestructively allows testing even commercial cells in their actual operating conditions, as a function of state of charge. These measurements provide maps of the magnetic susceptibility of the cell, which follow trends characteristic for the battery materia…
Phase separated Cu@Fe3O4 heterodimer nanoparticles from organometallic reactants
2011
Cu@Fe3O4 heteroparticles with distinct morphologies were synthesized from organometallic reactants. The shape of the magnetic domains could be controlled by the solvent and reaction conditions. They display magnetic and optical properties that are useful for simultaneous magnetic and optical detection. After functionalization, the Cu@Fe3O4 heterodimers become water soluble. The morphology, structure, magnetic and optical properties of the as-synthesized heterodimer nanoparticles were characterized using transmission electron microscopy (TEM), X-ray diffraction (XRD), mossbauer spectroscopy, superconducting quantum interference device (SQUID) magnetometry, and dark field imaging. A special a…
New ultraportable data logger to perform magnetic surveys
2019
This article presents the realization of a device for magnetic surveys It is a flexible, user-reprogramable, lightweight, and compact tool that can be easily integrated with aerial and marine drones. The device can accurately measure the local magnetic anomalies. It is based on the Atmega 2560 microcontroller and a digital 3-axis fluxgate magnetometer.
Search for Magnetic Monopoles with the MoEDAL Forward Trapping Detector in 13 TeV Proton-Proton Collisions at the LHC
2017
MoEDAL is designed to identify new physics in the form of long-lived highly-ionising particles produced in high-energy LHC collisions. Its arrays of plastic nuclear-track detectors and aluminium trapping volumes provide two independent passive detection techniques. We present here the results of a first search for magnetic monopole production in 13 TeV proton-proton collisions using the trapping technique, extending a previous publication with 8 TeV data during LHC run-1. A total of 222 kg of MoEDAL trapping detector samples was exposed in the forward region and analysed by searching for induced persistent currents after passage through a superconducting magnetometer. Magnetic charges excee…
Suppression of nonlinear Zeeman effect and heading error in earth-field-range alkali-vapor magnetometers
2018
The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in-phase with the precessing magnetization. In an earth-range field, a multi-component asymmetric magnetic-resonance line with ? 60 Hz width collapses into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of th…