Search results for "mammography"
showing 9 items of 69 documents
Breast cancer screening programmes: Challenging the coexistence with opportunistic mammography.
2014
Abstract Objective This study investigated predictive factors of women's participation in organized mammography screening (OrgMS) and/or opportunistic mammography screening (OppMS) when the two screening modes coexist. Methods Questionnaires were sent to 6,000 women aged 51–74 years old invited to attend an OrgMS session between 2010 and 2011 in France. Data collected concerned the women's healthcare behaviour and their socioeconomic characteristics. Women without a personal or family history of breast cancer that could explain their participation in OppMS were retained in the generalized logits analysis. Results The data of 1,202 women were analysed. Of these, 555 (46.2%) had attended OrgM…
Multiparametric 18F-FDG PET-MRI of the breast: are there differences in imaging biomarkers of contralateral healthy tissue between patients with and …
2019
The rationale was to assess whether there are differences in multiparametric 18F-FDG PET/MRI biomarkers of contralateral healthy breast tissue in patients with benign and malignant breast tumors. Methods: In this institutional review board-approved prospective single-institution study, 141 women with imaging abnormalities on mammography or sonography (BI-RADS 4/5) underwent combined 18F-FDG PET/MRI of the breast at 3T with dynamic contrast-enhanced MRI, diffusion-weighted imaging, and the radiotracer 18F-FDG. In all patients, the following imaging biomarkers were recorded for the contralateral (tumor-free) breast: breast parenchymal uptake (BPU) (from 18F-FDG PET), mean apparent diffusion c…
Undetected Malignancies of the Breast: Dynamic Contrast-enhanced MR Imaging at 1.0 T
2002
To assess the prevalence and characteristics of malignant breast lesions not identified with magnetic resonance (MR) imaging.Breast tissue specimens were obtained in 464 of 967 patients who had undergone dynamic gadolinium-enhanced T1-weighted fast low-angle shot three-dimensional MR imaging of both breasts. A comparison of sensitivity, specificity, and predictive values of the prospectively recorded findings of mammography, ultrasonography (US), and MR imaging with the histopathologic results was performed with receiver operating characteristic (ROC) curve analysis. MR imaging examination findings that caused a false-negative diagnosis were reviewed to identify possible sources of error.Hi…
72P Non-mass like enhancement patterns on MR mammography and their pathological correlation
2020
Screening
2012
Background The early detection of cancer and other diseases is generally considered beneficial, yet there is evidence that in some diseases screening may be of limited benefit. To clarify this issue, we present the statistical principles that underlie screening. Methods We define screening and discuss the conditions for its successful use. We give illustrative examples from among the currently recommended types of screening in Germany and from the recent medical literature, particularly with regard to mammography.
Interdisciplinary Screening, Diagnosis, Therapy and Follow-up of Breast Cancer. Guideline of the DGGG and the DKG (S3-Level, AWMF Registry Number 032…
2018
62. Kongress der Deutschen Gesellschaft für Gynäkologie und Geburtshilfe, DGGG'18, Berlin, Germany, 31 Oct 2018 - 3 Nov 2018; Geburtshilfe und Frauenheilkunde 78(10), 927-948 (2018). doi:10.1055/a-0646-4522 special issue: "62. Kongress der Deutschen Gesellschaft für Gynäkologie und Geburtshilfe, DGGG'18, Berlin, 31.10 – 03.11.2018 : Frauenheilkunde im Fokus: wissenschaftlich fundiert und der Qualität verpflichtet"
Spiral-Computertomographie der Mamma
1994
Aim To evaluate the use of spiral CT in the diagnosis of breast lesions. Material and methods 93 female patients with suspicious or uncertain mammographic findings were examined by CT before and after contrast enhancement according to the following practical method: table movement, 6 mm/s, slice thickness 6 mm, increment 4 mm, contrast 200 ml, injection rate 3 ml/s, scan start 50 s after the beginning of the injection. Histological confirmation was present in 85 patients. Results All 44 invasive carcinomas were recognised. They were characterised by intensive focal contrast uptake. Only 2 out of 7 intraductal carcinomas were not shown by CT. 36 out of 38 benign lesions were correctly diagno…
Nachsorge des Mammakarzinoms
1994
7865 follow-up examinations were performed on 420 patients who had had surgery for carcinoma of the breast; there were 2755 radiographs of the chest, 2660 sonographic examinations of the upper abdomen and 2450 contralateral mammograms. The most common findings were metastases seen on the chest radiographs during the 13-24 and 25-60 months intervals in 4.7% of cases. The incidence increased with initially higher tumour stages and in ductal carcinomas. Sonography of the upper abdomen showed 4.3% of liver involvement, mostly between the second and fifth year; this was independent of tumour stage or the histology of the primary tumour. Positive mammography of the contralateral breast was found …
High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach
2010
Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the respon…