Search results for "masks"
showing 10 items of 49 documents
Face masks effectively limit the probability of SARS-CoV-2 transmission.
2021
Masking out air sharing The effectiveness of masks in preventing the transmission of severe acute respiratory syndrome coronavirus 2 has been debated since the beginning of the COVID-19 pandemic. One important question is whether masks are effective despite the forceful expulsion of respiratory matter during coughing and sneezing. Cheng et al. convincingly show that most people live in conditions in which the airborne virus load is low. The probability of infection changes nonlinearly with the amount of respiratory matter to which a person is exposed. If most people in the wider community wear even simple surgical masks, then the probability of an encounter with a virus particle is even fur…
Face masks considerably reduce COVID-19 cases in Germany
2020
Significance Mitigating the spread of COVID-19 is the objective of most governments. It is of utmost importance to understand how effective various public health measures are. We study the effectiveness of face masks. We employ public regional data about reported severe acute respiratory syndrome coronavirus 2 infections for Germany. As face masks became mandatory at different points in time across German regions, we can compare the rise in infections in regions with masks and regions without masks. Weighing various estimates, we conclude that 20 d after becoming mandatory face masks have reduced the number of new infections by around 45%. As economic costs are close to zero compared to oth…
The Covid-19 containment effects of public health measures:A spatial difference-in-differences approach
2021
Abstract The paper studies the containment effects of public health measures to curb the spread of Covid‐19 during the first wave of the pandemic in spring 2020 in Germany. To identify the effects of six compound sets of public health measures, we employ a spatial difference‐in‐differences approach. We find that contact restrictions, mandatory wearing of face masks and closure of schools substantially contributed to flattening the infection curve. The significance of the impact of restaurant closure does not prove to be robust. No incremental effect is evidenced for closure of establishments and the shutdown of nonessential retail stores.
Suction catheter guided insertion of the ProSeal™ laryngeal mask airway is superior to the digital technique
2006
We tested the hypothesis that digital insertion of the ProSeal laryngeal mask airway (ProSeal LMA) is more successful when using a suction catheter (SC) as a guide.Two hundred and forty-three patients (ASA physical status I-III; aged 18-84 yr) were randomly allocated for the digital or SC-guided technique. The digital technique was performed according to the manufacturer's instructions. The SC technique involved priming the drain tube with the SC so that it protruded by 15 cm, blindly inserting the SC into the pharynx to a depth of 15 cm, followed by the digital technique. Failed insertion was defined by any of the following criteria: 1) failed passage into the pharynx; 2) malposition; and …
Assessment of Pulmonary Mechanics and Gastric Inflation Pressure During Mask Ventilation
1995
AbstractIntroduction:Mask ventilation is a procedure routinely used in emergency medicine. Potential hazards are inadequate alveolar ventilation and inflation of the stomach with air, leading to subsequent regurgitation and aspiration. The aim of this study was to measure lung function and gastric inflation pressures during mask ventilation.Methods:For this purpose, 31 patients scheduled for routine urological procedures were studied during induction of anesthesia. Lung function was assessed by recording respiratory flow and pressure directly at the face mask. Gastric inflation was observed with a microphone taped to the epigastric area.Results:Gastric inflation occurred in 22 of the 31 pat…
Respiratory Mechanics, Gastric Insufflation Pressure, and Air Leakage of the Laryngeal Mask Airway
1997
A potential risk of the laryngeal mask airway (LMA) is incomplete mask seal, which causes air leakage or insufflation of air into the stomach. The objective of the present study was to assess respiratory mechanics, quantify air leakage, and measure gastric air insufflation in patients ventilated via the LMA. Thirty patients were studied after induction of anesthesia but prior to any surgical manipulations. After the insertion of the LMA, patients were ventilated with increasing tidal volumes until one of the three following end points were reached: 1) gastric air insufflation, 2) airway pressure > 40 cm H2O, or 3) limitation of further increase in tidal volume by air leakage. The following …
In vivo ultrasound real-time motion of the cervical spine during intubation under manual in-line stabilization: a comparison of intubation methods
2007
Background and objectiveIn emergency trauma situations, manual in-line stabilization of the cervical spine is recommended to reduce cervical spine movement during intubation. The aim of this study was to compare the effect of manual in-line stabilization during different intubation techniques on three-dimensional cervical spine movements and times to intubation.MethodsForty-eight subjects without any history of trauma, inflammatory or degenerative disorder of the cervical spine were randomly grouped, regardless of gender or age. All underwent elective surgery under general anaesthesia. Under manual in-line stabilization, laryngeal intubation with Macintosh laryngoscope, intubating laryngeal…
Performance of EasyBreath Decathlon Snorkeling mask for delivering continuous positive airway pressure
2021
AbstractDuring the COVID-19 pandemic, the need for noninvasive respiratory support devices has dramatically increased, sometimes exceeding hospital capacity. The full-face Decathlon snorkeling mask, EasyBreath (EB mask), has been adapted to deliver continuous positive airway pressure (CPAP) as an emergency respiratory interface. We aimed to assess the performance of this modified EB mask and to test its use during different gas mixture supplies. CPAP set at 5, 10, and 15 cmH2O was delivered to 10 healthy volunteers with a high-flow system generator set at 40, 80, and 120 L min−1 and with a turbine-driven ventilator during both spontaneous and loaded (resistor) breathing. Inspiratory CO2 par…
The novel video-assisted intubating laryngeal mask Totaltrack compared to the intubating laryngeal mask Fastrach - a controlled randomized manikin st…
2017
BACKGROUND The novel Totaltrack combines a supraglottic airway device with video laryngoscopic tracheal intubation. The intubation laryngeal mask Fastrach is an established device without visual control of intubation. We hypothesized that supraglottic ventilation success with Totaltrack would be similar to Fastrach, but intubation would be performed faster due to visual control of the procedure. METHODS Fifty-five anaesthesiologists were randomized into one of two study arms: Fastrach Totaltrack. After a standardized introduction, six consecutive attempts of supraglottic ventilation and intubation attempts with each of one of the devices were performed on an airway manikin. The combined pri…