Search results for "maximum"
showing 10 items of 753 documents
Analytical Expressions for Radiative Losses in Solar Cells
2019
Analytical expressions for the fundamental losses in single junction solar cells are revised and improved. The losses are, as far as possible, described using parameters with clear physical interpretations. One important improvement compared to earlier work is the use of Lambert’s W function, which allows for analytical expressions for the voltage and current at the maximum power point. Other improvements include the use of Stefan Boltzmann’s law to describe the incoming energy flux as well as taking into account the fermionic nature of the electrons when calculating the thermalization loss. A new expression, which combines emission, Boltzmann and Carnot losses, is presented. Finally, an ex…
Development of the wide field imager for Athena
2015
The WFI (Wide Field Imager) instrument is planned to be one of two complementary focal plane cameras on ESA's next X-ray observatory Athena. It combines unprecedented survey power through its large field of view of 40 arcmin x 40 arcmin together with excellent count-rate capability (>= 1 Crab). The energy resolution of the silicon sensor is state-of-the-art in the energy band of interest from 0.2 keV to 15 keV, e.g. the full width at half maximum of a line at 6 keV will be <= 150 eV until the end of the nominal mission phase. This performance is accomplished by using DEPFET active pixel sensors with a pixel size of 130 μm x 130 μm well suited to the on-axis angular resolution of 5 arcsec of…
X-ray spectroscopy and dosimetry with a portable CdTe device.
2007
Abstract X-ray spectra and dosimetry information are very important for quality assurance (QA) and quality control (QC) in medical diagnostic X-ray systems. An accurate knowledge of the diagnostic X-ray spectra would improve the patient dose optimization, without compromising image information. In this work, we performed direct diagnostic X-ray spectra measurements with a portable device, based on a CdTe solid-state detector. The portable device is able to directly measure X-ray spectra at high photon fluence rates, as typical of clinical radiography. We investigated on the spectral performances of the system in the mammographic energy range (up to ∼40 keV). Good system response to monoener…
Characterization of Al-Schottky CdTe detectors
2011
In the last decades, great efforts are being devoted to the development of CdTe detectors for high resolution X-ray and gamma ray spectroscopy. Recently, new rectifying contacts based on aluminum (Al) are very appealing in the development of CdTe detectors with low leakage currents and anode pixellization. In this work, we report on preliminary results of electrical and spectroscopic investigations on Schottky CdTe diode detectors (4.1 × 4.1 × 0.75 and 4.1 × 4.1 × 2 mm3) with Au/Ti/Al/CdTe/Pt electrode configuration. The detectors are characterized by very low leakage currents even at room temperature (26 pA at 25 °C under a bias voltage of −100 V for the 2 mm thick detector). Polarization …
High-Energy pulse profile of the Transient X-ray Pulsar SAX J2103.5+4545
2005
In two recent INTEGRAL papers, Lutovinov et al. (2003) and Blay et al. (2004) report a timing and spectral analysis of the transient Be/X-ray pulsar SAX J2103.5+4545 at high energies (5--200 keV). In this work we present for the first time a study of the pulse profile at energies above 20 keV using INTEGRAL data. The spin-pulse profile shows a prominent (with a duty cycle of 14%) and broad (with a FWHM of ~ 51 s) peak and a secondary peak which becomes more evident above 20 keV. The pulsed fraction increases with energy from ~ 45% at 5--40 keV to ~ 80% at 40--80 keV. The morphology of the pulse profile also changes as a function of energy, consistent with variations in the spectral componen…
Active reduction of fluctuations in fourth-order modulation instability
2012
International audience; We experimentally study the fluctuation properties of a scalar fourth-order modulation instability process obtained by pumping a photonic crystal fiber in the normal dispersion region. We observe large wavelength-dependant pulse-to-pulse fluctuations which cannot be significantly reduced by stimulating the process with a single seed. Their reduction requires two seeds slightly detuned from the maximum gain frequency in order to also stimulate the second-order modulation instability process cascaded from the fourth-order one. This concept is validated by experiments and numerical simulations.
Elastic Metasurfaces for Deep and Robust Subwavelength Focusing and Imaging
2021
International audience; Metasurfaces are planar metamaterials with a flat surface and a subwavelength thickness that are able to shape arbitrary wave fronts such as focusing or imaging. There is a broad interest in the literature about subwavelength focusing and imaging based on bulk metamaterials while the utilization of metasurfaces for elastic waves has rarely been reported. Here, we present a type of elastic metasurface consisting of a line of gradient resonant pillars for robust deep subwavelength focusing and imaging of elastic waves in a plate. Numerical approaches supported by analytic Huygens-Fresnel demonstrations show that the subwavelength full width at half maximum (FWHM) behav…
Dielectric metalenses with engineered point spread function
2017
High-index silicon nanoblocks support excitation of both electric and magnetic resonance modes at telecommunication wavelengths. At frequencies where both electric and magnetic resonance modes are excited simultaneously, changing the geometrical dimensions of the silicon cubes creates a 2π full span over the phase of the transmitted light in different amplitude ranges. We take advantage of the additional power-flux modulation of the scattered signal to focus the incident light with desired full width at half maximum (FWHM) and side lobe levels (SLLs) in both the lateral and axial directions. By implementing proper amplitude filters within the telecommunication working wavelength (1.55 μm), …
High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach
2010
Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the respon…
High performance 3D CZT spectro-imager for BNCT-SPECT: preliminary characterization
2018
The National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project with the aim of developing a new Single Photon Emission Computed Tomography (SPECT) system for real time 10 B therapeutic dose monitoring in the binary experimental hadron therapy called Boron Neutron Capture Therapy (BNCT). BNCT is a highly selective tumour treatment based on the neutron capture reaction 10 B(n,α) 7 Li. The secondary particles have a high LET with ranges in tissues of the order of 10 μm (thus less than the mean cell diameter of few tens μm). Targeting the 10 B delivery towards cancer, the released energy lethally damages only the malignant cells sparing the normal tissues, thus enabling a cell…