Search results for "medical physics"
showing 10 items of 579 documents
Whole-body magnetic resonance imaging and FDG-PET/CT for lymphoma staging: Assessment of patient experience
2017
Purpose: To compare patient experience of whole-body MRI and FDG-PET/CT performed for lymphoma staging. Methods: One-hundred-fifteen patients (59 males, 56 females; 53 Hodgkin, 62 non-Hodgkin; mean age: 43.8 years) with lymphoma underwent whole-body MRI and FDG-PET/CT for staging and filled a questionnaire regarding their experience of the examinations using a 4-point Likert scale (1, very good; 4,very bad). Differences were evaluated using Wilcoxon signed-rank test. Patients were asked to express their preference on both techniques. Preferences were compared on the basis of gender, age, and Ann Arbor stage using the chi-square test. A p-value ≤ .05 was considered significant. Results: Most…
Detection of cancer through exhaled breath: a systematic review
2015
// Agne Krilaviciute 1 , Jonathan Alexander Heiss 1 , Marcis Leja 2 , Juozas Kupcinskas 3 , Hossam Haick 4 and Hermann Brenner 1,5,6 1 Division of Clinical Epidemiology and Aging Research, German Cancer Research Center (DKFZ), Heidelberg, Germany 2 Faculty of Medicine, University of Latvia, Digestive Diseases Center GASTRO, and Riga East University Hospital, Riga, Latvia 3 Department of Gastroenterology, Lithuanian University of Health Sciences, Kaunas, Lithuania 4 Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion – Israel Institute of Technology, Haifa, Israel 5 Division of Preventive Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany…
Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Asso…
2018
This Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on cardiovascular outcomes is summarized, and patients or lesions most likely to derive clinical benefit from an imaging-guided intervention are identified. The relevance of the u…
The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.
2014
Abstract The mixed neutron–photon beam of FiR 1 reactor is used for boron–neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple b…
Fourier-transform spectroscopy, direct potential fit, and electronic structure calculations on the entirely perturbed (4) 1Π state of RbCs
2018
We perform a high-resolution Fourier-transform spectroscopic study of the $(4){\phantom{\rule{0.16em}{0ex}}}^{1}\mathrm{\ensuremath{\Pi}}$ state of the RbCs molecule by applying two-step $(4){\phantom{\rule{0.16em}{0ex}}}^{1}\mathrm{\ensuremath{\Pi}}\ensuremath{\leftarrow}A{\phantom{\rule{0.16em}{0ex}}}^{1}{\mathrm{\ensuremath{\Sigma}}}^{+}\ensuremath{\sim}b{\phantom{\rule{0.16em}{0ex}}}^{3}\mathrm{\ensuremath{\Pi}}\ensuremath{\leftarrow}X{\phantom{\rule{0.16em}{0ex}}}^{1}{\mathrm{\ensuremath{\Sigma}}}^{+}$ optical excitation followed by observation of the $(4){\phantom{\rule{0.16em}{0ex}}}^{1}\mathrm{\ensuremath{\Pi}}\ensuremath{\rightarrow}X{\phantom{\rule{0.16em}{0ex}}}^{1}{\mathrm{\ensu…
Evaluation of a commercial APD array (Avalanche PhotoDiode) for a readout detector in a hadrontherapy beam characterization application
2010
The aim of the present work is the characterization of the S8898–128–02 Avalanche PhotoDiode array (APDs) from Hamamatsu Photonics. This work includes the implementation of a readout system as well as electronic noise estimation in APDs under several conditions varying integration times and clock frequencies.
Potentials for modeling cold collisions between Na (3S) and Rb (5S) atoms
2005
The experimental characterization of the electronic states correlated to the asymptote of ground state Na (3S) and Rb (5S) atoms was expanded by spectroscopic data on $a\phantom{\rule{0.2em}{0ex}}^{3}\ensuremath{\Sigma}^{+}$ state levels using a high resolution Fourier transform spectroscopy technique. The hyperfine splitting of the $a\phantom{\rule{0.2em}{0ex}}^{3}\ensuremath{\Sigma}^{+}$ state levels was partially resolved and analyzed for both $\mathrm{Na}\phantom{\rule{0.2em}{0ex}}^{85}\mathrm{Rb}$ and $\mathrm{Na}\phantom{\rule{0.2em}{0ex}}^{87}\mathrm{Rb}$ isotopomers. Transitions to high lying levels of the $a\phantom{\rule{0.2em}{0ex}}^{3}\ensuremath{\Sigma}^{+}$ and $X\phantom{\rul…
Linear inverse filtering improves spatial separation of nonlinear brain dynamics: a simulation study.
2000
We examined topographic variations in nonlinear measures based on scalp voltages, which were generated by two simulated current dipoles each placed in a different hemisphere of a spherical volume conductor (three-shell model). Dipole dynamics were that of a three-torus and the x-component of the Lorenz-system and scalp voltage were calculated for a configuration of 29 electrode positions. Although estimates for correlation dimension D2 and Lyapunov exponent L1 were close to the theoretical values for the original time series, the simulated scalp voltage data showed almost no topographic resolution of dipole positions. In order to enhance topographic differentiation, we constructed linear in…
Extension of Electron Monte Carlo Dose Calculation in Eclipse to Siemens Linear Accelerators
2009
Initially, the implementation of the macro Monte Carlo (MC) method into Eclipse (Varian Medical Systems), named eMC, was carried out for Varian accelerators only. In this work eMC algorithm has been modified to allow also accurate dose calculations for electron beams for Siemens accelerators.
Energy-loss straggling of 2-10 MeV/u Kr ions in gases
2013
Measurements have been performed on a time-of-flight setup at the Jyväskylä K130 cyclotron, aiming at energy-loss straggling of heavy ions in gases. Theoretical predictions based on recently developed theory as well as an empirical interpolation formula predict that straggling can be more than ten times higher than Bohr straggling in the MeV/u regime. Our measurements with up to 9.3 MeV/u Kr ions on He, N2, Ne and Kr targets confirm this feature. Our calculations show the relative contributions of linear straggling, bunching including packing, and charge exchange. Our results for stopping cross sections are compatible with values from the literature. Funding Agencies|EU||Academy of Finland …