A novel approach based on nonactive powers for the identification of disturbing loads in power systems
2007
In this paper, a new approach is proposed for the detection of harmonic sources in polluted power systems. It is a single- point strategy, based on a comparison among different "nonactive" power quantities proposed in literature that, in the same working conditions, assume different values at the same metering section. Some simulations tests were carried out on a standard IEEE test system proposed by other authors as a benchmark system for the analysis of multipoint measurement techniques for harmonic pollution monitoring. The obtained results show that the proposed single-point approach is in agreement with other strategies already proposed in the literature and can provide useful indicati…
A time domain strategy for the measurement of IEEE Standard 1459-2000 power quantities in nonsinusoidal three-phase and single-phase systems
2008
This paper describes a time domain technique for the detection of fundamental and harmonic components of voltages and currents, which is able to evaluate all the quantities required by IEEE standard 1459-2000. The technique does not require any spectral analysis to separate the fundamental positive-sequence components from harmonic, negative-sequence and zero-sequence ones. In the paper the development of the proposed technique is presented for three-phase systems, both three-wires and four-wires, as well as for single-phase systems. The implementation of the proposed technique on a PC-based instrument is also described and experimental results are presented. Finally, accuracy specification…
A Time-Domain Approach Based on the IEEE Std 1459-2000 for the detection of Loads Producing Harmonic Distortion
2008
This paper presents a novel strategy for the detection of harmonic sources in power systems for both the single-phase and the three-phase systems. It is based on the IEEE Std. 1459-2000 approach and it is based only on the separation of the fundamental components from the harmonic content of voltage and current. The proposed strategy do not require any spectral analysis of voltages and currents and it can be entirely implemented in the time domain. In the paper, the formulation of the novel approach is given and some simulation results are presented.
Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers
2007
This paper presents an innovative technique for the detection of disturbing loads in distorted power systems. It is a single-point strategy, based on a comparison among different "nonactive" power quantities already proposed in literature, that are measured at the same metering section. In the paper, the results obtained with the application of the proposed technique are compared with those of other techniques for the monitoring of the harmonic pollution, both single-point and multi-point. Moreover, the effectiveness of the strategy is discussed, considering also the errors of the measurement transducers.
Comparison of Nonactive Powers for the Detection of Dominant Harmonic Sources in Power Systems
2008
This paper deals with an innovative technique for the detection of disturbing loads in distorted power systems. The technique is a single-point strategy based on a comparison among different ldquononactiverdquo power quantities already proposed in the literature, which are measured at the same metering section. In this paper, the effectiveness of the strategy is discussed, which also considered the errors of the measurement transducers; the analysis is supported by simulation tests, which were carried out on both a simple single-phase system and an IEEE standard three-phase test power system. The latter was used by other authors as a benchmark system for the analysis of multipoint measureme…
An enhanced approach based on IEEE 1459 for the detection of disturbing loads in distorted and unbalanced three-phase power systems
2009
This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems in both cases of three and four-wires. It is based on the IEEE Std. 1459-2000 effective apparent power resolution and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In the paper, the formulation of the novel approach is given and some simulation results are presented.
Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000
2009
This paper presents a single-point method for the identification of prevailing disturbing loads in power systems for both single-phase and three-phase applications downstream or upstream from the metering section. It is based on the simultaneous measurement of three nonactive power quantities, which are based on the IEEE Std. 1459-2000 approach. The proposed method is only based on the separation of the fundamental components from the harmonic content of voltage and current; thus, it does not require any spectral analysis of the voltages and current. In this paper, the formulation of the proposed method and its time-domain implementation are described; moreover, some simulation results are …
Comparison of two different approaches for harmonic distortion sources assessment
2021
The paper focuses the attention on the comparison of two approaches for power quality assessment in the electric grid. Both approaches are suitable for investigating the harmonic pollution source and discovering if the harmonic source comes from the customer or the utility grid. The two approaches have the same purpose but they are deeply different. The first approach is based on the knowledge of the customer and utility equivalent impedance while the second is based on single point measurement at point of common coupling PCC. In this paper, the advantages and drawbacks of the two approaches are investigated also supported by a case study.
Relazione di sintesi.
2015
Si tratta della Relazione di sintesi nel Convegno su «La tela di Penelope e i rapporti tra “penale” e “tributario”: una orditura possibile?», organizzato dal Centro Siciliano di Studi sulla Giustizia, dall’Università LUMSA e dall’AIGA, tenutosi a Palermo il 21 aprile 2016, nella Aula Magna Facoltà di Giurisprudenza Università LUMSA.
Double squirrel cage induction motors: A new approach to detect rotor bar failures
2013
The purpose of this paper is to present a diagnosis technique, for rotor broken bar in double cage induction motor, based on a combined use of frequency sliding and wavelet transform analysis, to isolate the contribution of the rotor fault components issued from vibration signals in a single frequency band. The validity of the proposed diagnosis approach is not limited to the analysis under steady-state operating conditions, but also for time-varying conditions where rotor fault components are spread in a wide frequency range.