Search results for "mittausmenetelmät"
showing 10 items of 83 documents
Cost-efficiency assessments of marine monitoring methods lack rigor—a systematic mapping of literature and an end-user view on optimal cost-efficienc…
2021
Global deterioration of marine ecosystems, together with increasing pressure to use them, has created a demand for new, more efficient and cost-efficient monitoring tools that enable assessing changes in the status of marine ecosystems. However, demonstrating the cost-efficiency of a monitoring method is not straightforward as there are no generally applicable guidelines. Our study provides a systematic literature mapping of methods and criteria that have been proposed or used since the year 2000 to evaluate the cost-efficiency of marine monitoring methods. We aimed to investigate these methods but discovered that examples of actual cost-efficiency assessments in literature were rare, contr…
Soil moisture variations from boreal forests to the tundra
2023
Soil moisture has a profound influence on life on Earth, and this vital water resource varies across space and time. Here, we explored soil moisture variations in boreal forest and tundra environments, where comprehensive soil moisture datasets are scarce. We installed soil moisture sensors up to 14 cm depth at 503 measurement sites within seven study areas across northern Europe. We recorded 6,138,528 measurements to capture soil moisture variations of the snowless season from April to September 2020. We described the spatio-temporal patterns of soil moisture, and test how these patterns are linked to topography and how these links vary in space and time. We found large spatial variation a…
Translation and Validation of a Brief Health Literacy Instrument for School-Age Children in a Danish Context
2022
Low health literacy (HL) is associated with adverse health behaviors and poor health, and brief, high-quality instruments for measuring HL in children are scarce. The Health Literacy for School-Aged Children (HLSAC) instrument is a 10-item theory-based and internationally validated tool for measuring HL. The purpose of this study was to translate and validate the HLSAC instrument among Danish school-aged children. The instrument was translated into Danish by a standardized forward-backward translation process, and then pre-tested for face validity with 61 pupils from four schools. Thereafter, the instrument was tested among 805 pupils in grades 6 to 7 (age 11–14 years) from 15 schools. Whe…
Jump Height from Inertial Recordings : A Tutorial for a Sports Scientist
2019
Jump performance provides meaningful information both for sporting and clinical needs. Current state-of-the-art in jump performance assessment is laboratory-bound, however, out-of-the-laboratory methods are desirable. Therefore, the purposes of the present investigation were 1) to explore whether utilising a novel analytical approach minimises the bias between inertial recording unit (IMU)-based and jump mat-based jump height estimates, and 2) to provide a thorough tutorial for a sport scientist (see appendix) to facilitate standardisation of jump height estimation. Forty one women, men and boys aged 6 to 77 years-of-age completed three maximal counter movement jumps without arm swing, whic…
The reliability of measuring medial gastrocnemius muscle-tendon unit lengths during gait
2021
Background Ultrasound imaging combined with 3D motion analysis allows for in-vivo assessment of muscle-tendon unit lengths during gait. The clinical relevance of analysing the medial gastrocnemius (MG) and Achilles muscle-tendon junction (MTJ), MG mid-muscle belly fascicles (FAS) and muscle thickness was shown. However, their reliability error estimations over the gait cycle is unknown. Research question What are the intra- and inter-session errors associated with extracting MG belly, thickness, FAS and tendon lengths using ultrasound during gait in healthy participants? Methods 3D gait analysis was carried out in ten healthy adults as they walked on an instrumented treadmill at a comfortab…
How adherence to the updated physical activity guidelines should be assessed with accelerometer?
2022
Abstract Background The aerobic part of the recently updated physical activity (PA) guidelines for adults recommends at least 150 min of moderate or at least 75 of vigorous-intensity PA or an equivalent combination of both. PA can be accumulated of any bout duration. On an absolute scale, moderate-intensity threshold is 3 metabolic equivalents (METs) and vigorous 6 METs. On a scale relative to individual’s personal capacity, moderate-intensity threshold is 40% and vigorous 60% of the oxygen uptake reserve. In this study, the adherence to the new guidelines was evaluated using both absolute and relative thresholds. Methods Totally, 1645 adults aged 20–64 years, participated in this populatio…
Association Between Free-Living Sit-to-Stand Transition Characteristics, and Lower-Extremity Performance, Fear of Falling, and Stair Negotiation Diff…
2022
Abstract Background Good sit-to-stand (STS) performance is an important factor in maintaining functional independence. This study investigated whether free-living STS transition volume and intensity, assessed by a thigh-worn accelerometer, is associated with characteristics related to functional independence. Methods Free-living thigh-worn accelerometry was recorded continuously for 3–7 days in a population-based sample of 75-, 80-, and 85-year-old community-dwelling people (479 participants; women n = 287, men n = 192). The records were used to evaluate the number and intensity (angular velocity of the STS phase) of STS transitions. Associations with short physical performance battery (SPP…
Long-term reliability of the Finnish behavioral and emotional rating scale
2015
In previous research, the Finnish version of the Behavioral and Emotional Rating Scale-2 has demonstrated adequate internal consistency, factor structure and convergent validity. The purpose of the present study was to examine the long-term test-retest reliability of the Finnish BERS-2. Youth, parent and teacher BERS-2 ratings were collected once a year for three years in order to assess the stability of scores. All of the correlations were significant and moderate to very large in magnitude. Study limitations, future research and implications were discussed.
Body composition in 18 to 88-year-old adults - comparison of multifrequency bioimpedance and dual-energy X-ray absorptiometry
2014
Objective -- This study compared bioimpedance analysis (BIA) in the assessment of body composition with dual-energy X-ray absorptiometry (DXA) in 18- to 88-year-old adults. Design and Methods -- Body composition of 882 adults was estimated by eight-polar BIA and DXA. In addition, estimates of lean mass, fat mass, and percentage of fat were investigated across a range of age and leisure time physical activity (LTPA) groups. Results -- Compared to DXA, larger lean masses (mean difference 2.9 and 1.6 kg) and smaller fat masses (3.1 and 2.6 kg) were estimated by BIA in both women and men, respectively. Differences between the methods' mean values were evident in all age and LTPA groups, except …
Measuring psychosocial stress with heart rate variability-based methods in different health and age groups
2022
Abstract Objective. Autonomic nervous system function and thereby bodily stress and recovery reactions may be assessed by wearable devices measuring heart rate (HR) and its variability (HRV). So far, the validity of HRV-based stress assessments has been mainly studied in healthy populations. In this study, we determined how psychosocial stress affects physiological and psychological stress responses in both young (18–30 years) and middle-aged (45–64 years) healthy individuals as well as in patients with arterial hypertension and/or either prior evidence of prediabetes or type 2 diabetes. We also studied how an HRV-based stress index (Relax-Stress Intensity, RSI) relates to perceived stress …