Search results for "monitoring system"

showing 7 items of 57 documents

Integration Data Model of the Bathymetric Monitoring System for Shallow Waterbodies Using UAV and USV Platforms

2022

Changes in the seafloor relief are particularly noticeable in shallow waterbodies (at depths up to several metres), where they are of significance for human safety and environmental protection, as well as for which the highest measurement accuracy is required. The aim of this publication is to present the integration data model of the bathymetric monitoring system for shallow waterbodies using Unmanned Aerial Vehicles (UAV) and Unmanned Surface Vehicles (USV). As part of this model, three technology components will be created: a hydroacoustic and optoelectronic data integration component proposed by Dąbrowski et al., a radiometric depth determination component based on optoelectronic data u…

hydrographyshallow waterbodyGeneral Earth and Planetary Sciencesbathymetric monitoring systemdata integration ; bathymetric monitoring system ; shallow waterbody ; Unmanned Aerial Ve-hicle (UAV) ; Unmanned Surface Vehicle (USV) ; hydrographyUnmanned Surface Vehicle (USV)Unmanned Aerial Vehicle (UAV)data integrationSettore ICAR/06 - Topografia E Cartografia
researchProduct

Nurses' Perspectives on In-Home Monitoring of Elderlies's Motion Pattern

2017

In-home monitoring systems have been proposed to support aging in place and facilitate home care service. Through a qualitative approach the study explores nurses' existing challenges and perspectives of an in-home monitoring system. Results indicate that nurses base care decisions on multiple, and sometimes, unreliable information sources. However, access to information about elderlies' physical motion could support the care planning process by reducing ambiguity and raising attention. Hence, a simple and affordable system that largely relies on nurses to interpret the sensed data could bring additional value. peerReviewed

in-home monitoring systemshome care servicethe elderly
researchProduct

Influence of O2 on extra virgin olive oil fatty acids composition during malaxation

2017

Many variables are related to extra virgin olive oil (EVOO) quality and, therefore, to its polyphenols content and fatty acids composition including the steps that lead to EVOO extraction, considering that it is mainly contained in the vacuoles of the fruit mesocarp. The main steps of EVOO production are: harvest, crushing, malaxation, centrifugation, storage and filtration. Considering the olive oil extraction procedures, many studies have been conducted in recent years on oil mill plant and processes for improving EVOO quality. Malaxer is the most studied machine among all; it is responsible for malaxation, which represents a very important and critical step in the EVOO extraction process…

lcsh:Computer engineering. Computer hardwareExtra virgin olive oil malaxation oxygen real time monitoring systemlcsh:TP155-156lcsh:TK7885-7895lcsh:Chemical engineering
researchProduct

Design and fabrication of an ultra-flexible electrode system for invasive continuous monitoring during surgery

2009

This paper introduces the development, design and characterization of a tube with electrodes for stimulation and recording. This tube can be used as an operative monitoring system for thyroid surgery. In such surgeries damaging of the neural tissue can result in permanently malfunction. Continuous nerve monitoring can reduce significantly this risk.

medicine.medical_specialtyFabricationComputer sciencefungiNeural stimulationContinuous monitoringElectrodemedicinefood and beveragesTube (fluid conveyance)Monitoring systemSurgery
researchProduct

Prospective Validation of Facial Nerve Monitoring to Prevent Nerve Damage During Robotic Drilling

2019

Facial nerve damage has a detrimental effect on a patient's life, therefore safety mechanisms to ensure its preservation are essential during lateral skull base surgery. During robotic cochlear implantation a trajectory passing the facial nerve at <0.5 mm is needed. Recently a stimulation probe and nerve monitoring approach were developed and introduced clinically, however for patient safety no trajectory was drilled closer than 0.4 mm. Here we assess the performance of the nerve monitoring system at closer distances. In a sheep model eight trajectories were drilled to test the setup followed by 12 trajectories during which the ENT surgeon relied solely on the nerve monitoring system and…

medicine.medical_specialtylcsh:Surgery610 Medicine & healthENT surgeon03 medical and health sciences0302 clinical medicinerobotic surgerymedicineotorhinolaryngologic diseasesRobotic surgeryCochlear implantation610 Medicine & healthOriginal Research630 Agriculturebusiness.industrynerve stimulation electrodemonopolar and bipolarMonitoring systemlcsh:RD1-811Microcomputed tomography620 EngineeringFacial nerveneurophysiology monitoringSurgeryrobotic cochlear implantationRobotic systems030220 oncology & carcinogenesisSkull base surgery570 Life sciences; biologySurgerybusiness030217 neurology & neurosurgeryFrontiers in Surgery
researchProduct

BEM analysis of a piezoelectric structural health monitoring system for delamination detection

2013

In the present work a piezoelectric based structural health monitoring (SHM) system is analyzed with the aim of assessing the ability of the piezoelectric patch to detect both edge and embedded delaminations proper of flange-skin composite laminated structures. he boundary element model is developed for piezoelectric solids and is implemented by taking advantage of the multidomain technique to model laminated and cracked configurations. A non-linear spring model interface is then implemented in conjunction with an iterative procedure allowing for the simulation of the finite stiffness of the bonding layers as well as of the non-penetration condition of the delamination surfaces. he dynamic …

piezoelectricsMaterials scienceFracture mechanicPiezoelectric mediaStructural health monitoring DelaminationPiezoelectric devicePiezoelectricityPiezoelectric materialNon-penetration conditionFlangeStructural Healt MonitoringStructural health monitoring systems Boundary element methodmedicineFracture mechanics behaviorGeneral Materials ScienceLaminatingSettore ING-IND/04 - Costruzioni E Strutture AerospazialiBoundary element methodStrain energy release ratebusiness.industryMechanical EngineeringDelaminationComposite laminated structureStiffnessFracture mechanicsStructural engineeringBoundary element modelDamage detectionPiezoelectricityIterative methodFractureMechanics of MaterialsReciprocity (electromagnetism)DelaminationIdentification parameterStructural health monitoringmedicine.symptomStructural health monitoring (SHM)business
researchProduct

Multicriteria evaluation of alternatives for remote monitoring systems of municipal buildings

2014

Abstract Conservation of natural resources drives municipalities to monitor their heat, power and water consumption more accurately. The objective of this study was to evaluate different implementation possibilities for remote monitoring systems for the municipal buildings of two medium-sized municipalities, Hollola and Nastola in Southern Finland. Four different alternatives were considered: (1) a system by an external service provider, (2) a system provided by the local energy distribution company, (3) a system built by the municipalities themselves, and (4) using the current manual system but with more frequent data collection. The alternatives were evaluated in terms of multiple functio…

ta212EngineeringStochastic multicriteria acceptability analysista214Energy distributionData collectionOperations researchbusiness.industryMechanical Engineeringta1172Environmental resource managementMonitoring systemBuilding and ConstructionService providerNatural resourceWater consumptionta519Electrical and Electronic Engineeringbusinessta116ta218Civil and Structural EngineeringEnergy and Buildings
researchProduct