Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study
2019
AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …
A Passive-Marker-Based Optical System for Computer-Aided Surgery in Otorhinolaryngology: Development and First Clinical Experiences
1999
Objectives: To develop a new type of optical computer-aided surgery (CAS) device that overcomes some of the restrictions of common systems and to examine its accuracy and usability under laboratory and intraoperative conditions. Study Design: Prospective study using laboratory experiments and intraoperative data collection. Methods: An optical CAS system applying passive optical markers for coordinate determination was developed. Laboratory accuracy measurements were obtained on a Plexiglas model with known coordinates of fiducial markers, before and after predefined table movements. Intraoperative accuracy measurements were recorded from 24 patients undergoing endonasal surgery of the para…
[Respiratory muscle aids during an episode of aspiration in a patient with Duchenne muscular dystrophy].
2005
We report the case of a Duchenne muscular dystrophy patient with good bulbar function but severely decreased forced vital capacity (9%) and spontaneous peak cough flow (PCF) (2.35 L/s). The patient needed continuous noninvasive ventilation (NIV) consisting of a volumetric ventilator with a nighttime nasal mask and a daytime mouthpiece. He also required application of manually assisted coughing techniques by insufflation with a resuscitation bag and chest thrust (manually assisted PCF after maximum insufflation capacity of 4.33 L/s). An episode of serious food aspiration was resolved by his main caregiver through NIV and manually assisted coughing. Bronchoscopy under sedation using NIV with …
Ventilator Settings to Avoid Nuisance Alarms During Mouthpiece Ventilation
2016
BACKGROUND: A recent study found that activation of disconnection and low-pressure alarms is common during mouthpiece ventilation and may represent a major limitation to its use. The aim of this bench study was: (1) to investigate the technical aspects that can influence the setting of the ventilator during mouthpiece ventilation and (2) to provide a practical setting strategy to avoid the alarm activation. METHODS: Eight life-support ventilators able to deliver volume controlled ventilation were tested in a bench study using a single-limb non-vented circuit configuration connected to a standard mouthpiece. Disconnection and apnea alarm were turned off or set at the least sensitive setting.…
The right interface for the right patient in noninvasive ventilation: a systematic review
2022
Introduction Research in the field of noninvasive ventilation (NIV) has contributed to the development of new NIV interfaces. However, interface tolerance plays a crucial role in determining the beneficial effects of NIV therapy. Areas covered This systematic review explores the most significant scientific research on NIV interfaces, with a focus on the potential impact that their design might have on treatment adherence and clinical outcomes. The rationale on the choice of the right interface among the wide variety of devices that are currently available is discussed here. Expert opinion The paradigm 'The right mask for the right patient' seems to be difficult to achieve in real life. Rang…