Search results for "mri"
showing 10 items of 733 documents
Comparison of 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine-enhanced MRI in 471 patients with known or suspected renal lesions : results of a mu…
2008
The purpose of this phase III clinical trial was to compare two different extracellular contrast agents, 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine, for magnetic resonance imaging (MRI) in patients with known or suspected focal renal lesions. Using a multicenter, single-blind, interindividual, randomized study design, both contrast agents were compared in a total of 471 patients regarding their diagnostic accuracy, sensitivity, and specificity to correctly classify focal lesions of the kidney. To test for noninferiority the diagnostic accuracy rates for both contrast agents were compared with CT results based on a blinded reading. The average diagnostic accuracy across the three bli…
Outcome of LR-3 and LR-4 observations without arterial phase hyperenhancement at Gd-EOB-DTPA-enhanced MRI follow-up
2020
Objective: The aim of this study was to retrospectively analyze the outcome of LR-3 and LR-4 without arterial phase hyperenhancement (APHE), and identify which features could predict LR-5 progression on serial Gd-EOB-DTPA-enhanced MRI follow-up. Methods: Forty-nine cirrhotic patients with 55 LR-3 and 19 LR-4 without APHE were evaluated. Observations were classified as decreased, stable or increased in category at follow-up. Observation size and LI-RADS major and ancillary features were evaluated. Results: Seventeen/fifty-five (31%) LR-3 and 8/19 (42%) LR-4 progressed to LR-5 at follow-up. Baseline LI-RADS major and ancillary features were not significantly different among LR-3 and LR-4. A d…
Gadoxetate disodium-enhanced magnetic resonance cholangiography for the noninvasive detection of an active bile duct leak after laparoscopic cholecys…
2010
Abstract We report a case of an endoscopically confirmed biliary leak of the common hepatic duct after laparoscopic cholecystectomy that was prospectively diagnosed on gadoxetate disodium-enhanced magnetic resonance cholangiography. Whereas dynamic contrast-enhanced magnetic resonance images during the early vascular phases helped to rule out the causes of possible complications such as seroma, hematoma, or abdominal abscess, delayed hepatobiliary phase imaging was crucial for unequivocal diagnosis and location of the biliary leak. The diagnosis prompted therapeutic endoscopic retrograde cholangiography whereby a polytetrafluoroethylene-covered nitinol stent graft was successfully placed to…
MRI-Visible Poly(ε-caprolactone) with Controlled Contrast Agent Ratios for Enhanced Visualization in Temporary Imaging Applications
2013
International audience; Hydrophobic macromolecular contrast agents (MMCAs) are highly desirable to provide safe and efficient magnetic resonance (MR) visibility to implantable medical devices. In this study, we report on the synthesis and evaluation of novel biodegradable poly(ε-caprolactone)-based MMCAs. Poly(α-propargyl-ε-caprolactone-co-ε-caprolactone)s containing 2, 5, and 10 mol % of propargyl groups have been prepared by ring-opening copolymerization of ε-caprolactone and the corresponding propargylated lactone. In parallel, a diazido derivative of the clinically used diethylenetriaminepentaacetic acid (DTPA)/Gd3+ complex has been synthesized. Finally, MRI-visible poly(ε-caprolactone)…
Reply to "Oxaliplatin-Induced Liver Changes on Gadoxetate Disodium-Enhanced Liver MRI".
2018
ASSESSMENT INTEGRATO NELLA DIPENDENZA DAL GIOCO D’AZZARDO: DALLA PSICODIAGNOSI AL NEUROIMAGING
PVA-GTA Fricke gel dosimeters exposed to clinical photons beams: Nuclear Magnetic Resonance Relaxometry and Imaging
2016
Fricke Gel (FXGs) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. The application of Fricke gels for ionizing radiation dosimetry is continuously increasing worldwide due to their many favorable properties. However, one of their shortcomings is that ferrous and ferric ions diffuse in the gel matrix. To maintain the spatial integrity of the dose distribution, Fricke gels must be undergoing measurement within a few hours of their irradiation, so that ferric ions remain close to their point of production. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained (Schreiner, 2015). The gel matrix also contributes to the oxidati…
Gel di Fricke: studio della risposta NMR in funzione della concentrazione di ferro ed utilizzo dosimetrico in ambito clinico (3D MRI)
2014
Encapsulation of xenon by bridged resorcinarene cages with high 129Xe NMR chemical shift and efficient exchange dynamics
2023
Functionalized cages encapsulating xenon atoms enable highly sensitive, background-free molecular imaging through a technique known as HyperCEST 129Xe MRI. Here, we introduce a class of potential biosensor cage structures based on two resorcinarene macrocycles bridged either by aliphatic carbon chains or piperazines. First-principles-based modeling predicts a high chemical shift (about 345 ppm) outside the typical experimental observation window for 129Xe encapsulated by the aliphatically bridged cage and two 129Xe resonances for the piperazine-bridged cages corresponding to single and double loading. Based on the computational predictions as well as 129Xe chemical exchange saturation trans…
Resting-State Functional Magnetic Resonance Imaging for Surgical Neuro-Oncology Planning: Towards a Standardization in Clinical Settings
2021
Resting-state functional magnetic resonance imaging (rest-f-MRI) is a neuroimaging technique that has demonstrated its potential in providing new insights into brain physiology. rest-f-MRI can provide useful information in pre-surgical mapping aimed to balancing long-term survival by maximizing the extent of resection of brain neoplasms, while preserving the patient’s functional connectivity. Rest-fMRI may replace or can be complementary to task-driven fMRI (t-fMRI), particularly in patients unable to cooperate with the task paradigm, such as children or sedated, paretic, aphasic patients. Although rest-fMRI is still under standardization, this technique has been demonstrated to be feasible…