Search results for "multiple"
showing 10 items of 2678 documents
ORDINAL MEASUREMENTS WITH INTERVAL CONSTRAINTS IN THE EIA PROCESS FOR SITING A WASTE STORAGE AREA
2009
We describe application of multicriteria decision analysis (MCDA) in the Environmental Impact Assessment (EIA) procedure for siting a waste storage area. The world’s largest biofuel-based combined heat and power (CHP) plant was built in Pietarsaari, Finland. The plant produces certain byproducts, such as flue dust and bottom ash, which need to be processed and stored to prevent releases to the environment. Different storage sites will have different impacts on people, nature, and the economy. Cardinal measurement of the different impacts was considered too costly. Instead, ordinal measurement of all criteria was applied; i.e., experts ranked the alternative storage sites according to each c…
Analyses of Dual Polarization WDM and SCM Radio over Fiber and Radio over FSO for C-RAN Architecture
2016
En este trabajo se simulan y verifican experimentalmente los esquemas de transmisión para una Arquitectura de Red de Acceso Radio Centralizada (C-RAN) basados en la combinación de dos tecnologías: Radio sobre Fibra (RoF) y Radio sobre FSO (RoFSO). Las configuraciones propuestas se optimizan para la evolución a largo plazo (LTE) con un ancho de banda de 20 MHz utilizando una modulación de amplitud en cuadratura de 64-QAM en términos de magnitud de vector de error (EVM). En primer lugar, se comparan las mediciones de la multiplexación por división de polarización mediante la combinación de RoF y RoFSO (PDM-RoF/FSO) con los modelos de simulación. Esto se amplía con la combinación de PDM-Multip…
Effect of Channel-Quality Indicator Delay on HSDPA Performance
2007
This paper evaluates the effect of the channel estimation inaccuracy on the performance of an HSDPA system. This study provides some results from system level simulations that have been conducted over a very complete dynamic simulator which models an HSDPA system full compliant with specifications. This emulator allows performing multi-user transmission and link adaptation with a limited modulation and coding scheme (MCS) selection based on the channel quality indicator (CQI) modes. Many factors such as the user equipment (UE) speed, the employed scheduling algorithm or the traffic load have been considered in the assessment. Moreover the intrinsic constraints of a WCDMA system like HSDPA h…
A critical assessment of desalination operations in Sicily
2005
In this paper a brief history of desalination plants in Sicily is presented together with an in-depth description of processes and operating data, relevant to the plants actually operating on the island. 5 multi stage flash (MSF) units and one reverse osmosis (RO) plant are operating in Gela (total nominal production of about 80,000 m 3 /d), thus providing drinking water for more than 300,000 people living in the southern coast of the island. A thermal vapour compression multiple effect distillation (TVC-MED) plant (36,000 m 3 /d) is operating in Trapani and a small mechanical vapour compression (MVC) unit (5000 m 3 /d) is located in Porto Empedocle. In the oldest MSF units in Gela, several…
Energy saving with MSF-RO series desalination plants
2003
Two major techniques are commercially used in different parts of the world: distillation and membrane processes. The dominant distillation process is multi-stage flash (MSF), and the main membrane process is reverse osmosis (RO). Although cost factors vary by site, the total cost of producing potable water from seawater with the RO process is today usually less than thermal desalting processes and the economic advantages of RO vs. evaporation process, such as MSF, are responsible for the rapid increase in use of seawater RO. In many countries both RO and MSF processes are operating. Reduction in product water cost could be achieved when a hybrid MSF-RO system is used, instead of a parallel …
A review of multiple faults diagnosis methods in Voltage Source Inverters
2015
This paper examines, as in short review, the methods of diagnosis of simple and multiple faults on Voltage Source Inverter (VSI). The methods examined here are essentially based on the inspection of the load currents. Some of these diagnosis methods are characterized by low computational effort, other for a better reliability avoiding faultless positive tests. Some solutions are characterized by a share of these benefits while others prefer an enforcement of trustworthiness, in spite of the lower calculation amount. The analysis of the technical literature, certainly, offers a glimpse about the creation of new algorithms and significant advances for the future.
Development of an optical link card for the upgrade phase II of TileCal experiment
2010
This work presents the design of an optical link card developed in the frame of the R&D activities for the phase 2 upgrade of the TileCal experiment as part of the evaluation of different technologies for the final choice in the next two years. The board is designed as a mezzanine which can work independently or plugged in the Optical Multiplexer Board of the TileCal backend electronics. It includes two SNAP 12 optical connectors able to transmit and receive up to 75 Gbps and one SFP optical connector for lower speeds and compatibility with existing hardware as the Read Out Driver. All processing is done in a Stratix II GX FPGA. Details are given on the hardware design including signal and …
A structured filter for Markovian switching systems
2014
In this work, a new methodology for the structuring of multiple model estimation schemas is developed. The proposed filter is applied to the estimation and detection of active mode in dynamic systems. The discrete-time Markovian switching systems represented by several linear models, associated with a particular operating mode, are studied. Therefore, the main idea of this work is the subdivision of the models set to some subsets in order to improve the detection and estimation performances. Each subset is associated with sub-estimators based on models of the subset. In order to compute the global estimate and subset probabilities, a global estimator is proposed. Theoretical developments ba…
A novel solar trigeneration system integrating PVT (photovoltaic/thermal collectors) and SW (seawater) desalination: Dynamic simulation and economic …
2014
Abstract The paper investigates the integration of renewable energy sources and water systems, presenting a novel solar system producing simultaneously: electrical energy, thermal energy, cooling energy and domestic water. Such system is designed for small communities in European Mediterranean countries, rich in renewable sources and poor in fossil fuels and water resources. The polygeneration system under analysis includes PVT (photovoltaic/thermal solar collectors), a MED (multi-effect distillation) system for SW (seawater) desalination, a single-stage LiBr–H2O ACH (absorption chiller) and additional components, such as storage tanks, AHs (auxiliary heaters) and BOP (balance of plant) dev…
Efficient pipeline FFT processors for WLAN MIMO-OFDM systems
2005
The most area-efficient pipeline FFT processors for WLAN MIMO-OFDM systems are presented. It is shown that although the R2/sup 3/SDF architecture is the most area-efficient approach for implementing pipeline FFT processors, RrMDC architectures are more efficient in MIMO-OFDM systems when more than three channels are used.