Search results for "musculoskeletal system"
showing 10 items of 795 documents
Changes in muscle activity with increasing running speed.
2005
Electromyographic (EMG) activity of the leg muscles and the ground reaction forces were recorded in 17 elite male middle-distance runners, who performed isometric maximal voluntary contractions (MVC) as well as running at different speeds. Electromyograms were recorded from the gluteus maximus, vastus lateralis, biceps femoris, gastrocnemius and tibialis anterior. The results indicated that the averaged EMG (aEMG) activities of all the muscles studied increased (P < 0.05) with increasing running speed, especially in the pre-contact and braking phases. At higher speeds, the aEMG activities of the gastrocnemius, vastus lateralis, biceps femoris and gluteus maximus exceeded 100% MVC in these s…
Effects of 12-wk eccentric calf muscle training on muscle-tendon glucose uptake and SEMG in patients with chronic Achilles tendon pain
2014
High-load eccentric exercises have been a key component in the conservative management of chronic Achilles tendinopathy. This study investigated the effects of a 12-wk progressive, home-based eccentric rehabilitation program on ankle plantar flexors' glucose uptake (GU) and myoelectric activity and Achilles tendon GU. A longitudinal study design with control ( n = 10) and patient ( n = 10) groups was used. Surface electromyography (SEMG) from four ankle plantar flexors and GU from the same muscles and the Achilles tendon were measured during submaximal intermittent isometric plantar flexion task. The results indicated that the symptomatic leg was weaker ( P < 0.05) than the asymptomatic…
Electrical and mechanical H(max)-to-M(max) ratio in power- and endurance-trained athletes.
2001
The aim of this study was to compare the mechanical and electromyographic (EMG) characteristics of soleus motor units activated during maximal H reflex and direct M response among subjects with different histories of physical activity. Power-trained athletes produced stronger twitches, with a higher rate of twitch tension buildup and relaxation, than their endurance counterparts for both maximal H-reflex and maximal M-wave responses. The maximal H-reflex-to-maximal M-wave ratios for both force output (twitch) and EMG wave amplitude were significantly lower in power-trained than endurance-trained athletes. However, power-trained athletes exhibited a significantly greater twitch-to-EMG ratio…
Alterations of neuromuscular function after an ultramarathon.
2002
Neuromuscular fatigue of the knee extensor (KE) and plantar flexor (PF) muscles was characterized after a 65-km ultramarathon race in nine well-trained runners by stimulating the femoral and tibial nerves, respectively. One week before and immediately after the ultramarathon, maximal twitches were elicited from the relaxed KE and PF. Electrically evoked superimposed twitches of the KE were also elicited during maximal voluntary contractions (MVCs) to determine maximal voluntary activation. MVC and maximal voluntary activation decreased significantly after the ultramarathon (−30.2 ± 18.0% and −27.7 ± 13.0%, respectively; P < 0.001). Surprisingly, peak twitch increased after the ultramara…
Afferent contribution to locomotor muscle activity during unconstrained overground human walking:an analysis of triceps surae muscle fascicles
2010
Plantar flexor series elasticity can be used to dissociate muscle–fascicle and muscle–tendon behavior and thus afferent feedback during human walking. We used electromyography (EMG) and high-speed ultrasonography concomitantly to monitor muscle activity and muscle fascicle behavior in 19 healthy volunteers as they walked across a platform. On random trials, the platform was dropped (8 cm, 0.9 g acceleration) or held at a small inclination (up to ±3° in the parasagittal plane) with respect to level ground. Dropping the platform in the mid and late phases of stance produced a depression in the soleus muscle activity with an onset latency of about 50 ms. The reduction in ground reaction force…
The association between muscle EMG and perfusion in knee extensor muscles
2006
The relationships between electromyographic (EMG) activity and force as well as muscle blood flow and work have been well established. However, the association between muscle blood flow and EMG activity remains unsolved. Thus, to test the hypothesis that muscle EMG activity relates to muscle perfusion in different compartments of the quadriceps femoris (QF) muscle, 12 healthy male subjects were studied. During two very submaximal exercise bouts, at different exercise intensities, oxygen labelled radiowater and positron emission tomography were used to measure muscle perfusion. In addition, produced force of knee extensors and muscle EMG activity in the vastus lateralis (VL), vastus medialis…
Electromyographic activity related to aerobic and anaerobic threshold in ergometer bicycling
1985
Electromyographic activity (EMG) of the knee extensor musculature (m. vastus lateralis, m. vastus medialis, m. rectus femoris), triceps surae (m. gastrocnemius, m. soleus) and m. tibialis anterior was studied in ergometer bicycling at five different power outputs around aerobic (AerT) and anaerobic (AnT) thresholds. EMGs were sampled with surface electrodes for ten revolutions at the beginning, in the middle and at the end of each work load and integrated (IEMG) separately for each of the muscles and for the descending (work) and ascending (rest) phase of the revolution. The mean power frequency (MPF) of the power spectral density function for the descending periods was also calculated. The…
Superimposing hip extension on knee flexion evokes higher activation in biceps femoris than knee flexion alone.
2021
Hamstring muscle function during knee flexion has been linked to hamstring injury and performance. However, it is unclear whether knee flexion alone (KF) requires similar hamstring electromyography (EMG) activity pattern to simultaneous hip extension and knee flexion (HE-KF), a combination that occurs in the late swing phase of sprinting. This study examined whether HE-KF maximal voluntary isometric contraction (MVIC) evokes higher (EMG) activity in biceps femoris long head (BFlh) and semitendinosus (ST) than KF alone. Effects of shank rotation angles were also tested. Twenty-one males performed the above-mentioned MVICs while EMG activity was measured along ST and BFlh. Conditions were com…
Quadriceps Femoris Torque and EMG Activity in Seated versus Supine Position
2003
To compare voluntary and electrically evoked knee extensor torque, surface electromyography (EMG), and activation level obtained under seated versus supine position, i.e., with shortened versus lengthened rectus femoris (RF) muscle.The knee extensor torque obtained during maximal voluntary contractions (MVC) and after single and paired stimuli applied at rest was measured under seated (i.e., 90 degrees hip angle) and supine (i.e., 180 degrees hip angle) conditions. The associated EMG activity from biarticular RF and monoarticular vasti was also recorded, and activation level was estimated by means of the twitch interpolation technique.Knee extensor MVC was 10.6% higher in the seated compare…
Central and Peripheral Contributions to Fatigue after Electrostimulation Training
2006
Purpose: We examined the effect of 4 (WK4) and 8 wk (WK8) of neuromuscular electrical stimulation (NMES) training on both endurance time and mechanisms contributing to task failure. Methods: Ten males performed a fatiguing isometric contraction with the knee extensor muscles at 20% of maximal voluntary contraction (MVC) until exhaustion before (B), at WK4, and at WK8 of NMES training. The electromyographic (EMG) activity and muscle activation obtained under MVC were recorded before and after the fatiguing task to assess central fatigue. Torque and EMG responses obtained under electrically evoked contractions were examined before and after the fatiguing task to analyze peripheral fatigue. Re…