Search results for "myopia"

showing 10 items of 165 documents

Genome-wide meta-analyses of multiancestry cohorts identify multiple new susceptibility loci for refractive error and myopia

2013

Refractive error is the most common eye disorder worldwide and is a prominent cause of blindness. Myopia affects over 30% of Western populations and up to 80% of Asians. The CREAM consortium conducted genome-wide meta-analyses, including 37,382 individuals from 27 studies of European ancestry and 8,376 from 5 Asian cohorts. We identified 16 new loci for refractive error in individuals of European ancestry, of which 8 were shared with Asians. Combined analysis identified 8 additional associated loci. The new loci include candidate genes with functions in neurotransmission (GRIA4), ion transport (KCNQ5), retinoic acid metabolism (RDH5), extracellular matrix remodeling (LAMA2 and BMP2) and eye…

geenimeta-analyysilikinäköisyysmyopiagene
researchProduct

Prevalence of visual impairment and refractive errors in an urban area of Mexico

2019

AIM: To determine the distribution of refractive errors in a school-age population in Quintana Roo (Mexico) in the framework of an international cooperation campaign for the prevention of blindness. METHODS: A sample of 2647 school-age children (ranging from 5 to 14 years old) with a mean age of 9.1±1.9 years old were tested by trained volunteers for distance visual acuity (VA) and refractive errors. The first screening examination included uncorrected distance visual acuity (UDVA) and VA with a +2.00 D lens. Inclusion criteria for a second complete cycloplegic eye examination performed by an optometrist were UDVA <20/25 (0.10 logMAR or 0.8 decimal) and/or VA with +2.00 D ≥20/25. RESULTS: A…

hyperopiaRefractive errormedicine.medical_specialtyBilateral amblyopiaDistance visual acuitygenetic structuresPopulationVisual impairmentvisual impairmentBlindnessScreening Examination03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyOphthalmologyMyopiaMedicinemyopiarefractive erroreducationÓpticaInvestigationeducation.field_of_studyBlindnessmedicine.diagnostic_testbusiness.industryRefractive errorVisual impairmentmedicine.diseaseeye diseasesOphthalmologyHyperopialcsh:RE1-994Eye examination030221 ophthalmology & optometrysense organsmedicine.symptombusinessblindness
researchProduct

Iris Claw Phakic Lens—Intermediate and Long-term Corneal Endothelial Changes

1994

OBJECTIVE: To study the alterations in the corneal endothelial layer two years after the implantation of iris claw phakic lenses. STUDY DESIGN: Prospective study of postoperative results with a minimum follow-up of 6 months, maximum of two years and a mean of 14 months. SETTING: Department of Ophthalmology, ‘La Fe’ University Hospital, Department of Surgery of Valencia School of Medicine, Valencia, Spain. PATIENTS: Ninety eyes of 70 patients presenting high myopia who underwent anterior chamber phakic lens implantation with iris fixation IOLs in the last two years. MAIN OUTCOME MEASURES: Non-contact specular microscopy with video image system was used to perform examination of the corneal e…

medicine.medical_specialtyCorneal endotheliumgenetic structuresEndotheliumbusiness.industryHigh myopiaUniversity hospitaleye diseasesSurgeryOphthalmologymedicine.anatomical_structureOphthalmologymedicinesense organsIris (anatomy)businessIris clawProspective cohort studyFixation (histology)European journal of Implant and Refractive Surgery
researchProduct

Optical analysis to predict outcomes after implantation of a double intraocular lens magnification device.

2007

Purpose To analyze the effect of different optical parameters of the eye on the outcomes of implantation of a double intraocular lens (IOL) magnification device in patients with low vision. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The eye's refraction and magnification before and after surgery were evaluated using a theoretical eye model based on paraxial optics approximation. Four parameters on which refraction and magnification are dependent were evaluated: anterior chamber depth (ACD), axial length (AL), mean keratometry (Km), and the distance between the 2 implanted IOLs. The 4 variables were analyzed separately in the first stage. Next, different combi…

medicine.medical_specialtyOptics and PhotonicsBiometrygenetic structuresAnterior Chambermedicine.medical_treatmentMagnificationVision LowIntraocular lensEyeRefraction Ocularlaw.inventionOpticsLens Implantation IntraocularlawOphthalmologymedicineMyopiaHumansIn patientPhysicsLenses IntraocularKeratometerbusiness.industryParaxial approximationModels TheoreticalMagnification deviceRefractioneye diseasesSensory SystemsLow visionOphthalmologyHyperopiaTreatment OutcomeSurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Evaluation of Shared Genetic Susceptibility to High and Low Myopia and Hyperopia

2021

Importance: Uncertainty currently exists about whether the same genetic variants are associated with susceptibility to low myopia (LM) and high myopia (HM) and to myopia and hyperopia. Addressing this question is fundamental to understanding the genetics of refractive error and has clinical relevance for genotype-based prediction of children at risk for HM and for identification of new therapeutic targets. Objective: To assess whether a common set of genetic variants are associated with susceptibility to HM, LM, and hyperopia. Design, Setting, and Participants: This genetic association study assessed unrelated UK Biobank participants 40 to 69 years of age of European and Asian ancestry. Par…

medicine.medical_specialtyRefractive errorgenetic structuresEmmetropiaGenome-wide association study01 natural sciences03 medical and health sciences0302 clinical medicineInternal medicinemedicineGenetic predispositionMyopiaHumansGenetic Predisposition to Disease0101 mathematicsAlleleChildGenetic associationOriginal Investigationbusiness.industry010102 general mathematicsOdds ratioHeritabilitymedicine.diseaseRefractive Errorseye diseases3. Good healthOphthalmologyHyperopia030221 ophthalmology & optometrybusinessGenome-Wide Association StudyJAMA Ophthalmology
researchProduct

Rediscovering the macula of high myopia in the xxi century

2011

medicine.medical_specialtybusiness.industryOphthalmologyMEDLINEMedicineOptometryHigh myopiaGeneral MedicinebusinessArchivos de la Sociedad Española de Oftalmología (English Edition)
researchProduct

Macula structural and vascular differences in glaucoma eyes with and without high axial myopia

2021

AbstractAimsTo assess the thickness of various retinal layers, and the superficial vessel density (sVD) in the macula of glaucomatous eyes and their associations with axial length (AL) and visual field mean deviation (VFMD) to identify parameters useful for glaucoma management in myopic eyes.Methods248 glaucoma patients (401 eyes) participating in the Diagnostic Innovations in Glaucoma Study observational cohort representing 3 axial myopia groups (non-myopia: n=146 eyes; mild myopia: n=208 eyes; high myopia (AL&gt;26 mm): n=47 eyes) who completed macular OCT and OCT-Angiography imaging were included. The cross-sectional associations of AL and VFMD with the thickness of the ganglion cell inn…

medicine.medical_specialtygenetic structuresbusiness.industryNerve fiber layerGlaucomaRetinalmedicine.diseaseInner plexiform layereye diseasesGanglionVisual fieldchemistry.chemical_compoundmedicine.anatomical_structurechemistryOphthalmologymedicineWeak associationsense organsbusinessAxial myopia
researchProduct

Surgical management of retinal detachment because of macular hole in highly myopic eyes

2012

PURPOSE: The purpose of this study was to review the current management of macular hole retinal detachment in highly myopic eyes. METHODS: We searched English MEDLINE databases from January 1997 to January 2011 for surgical management of macular hole retinal detachment in highly myopic eyes. The main outcomes reported include retinal reattachment and visual acuity after primary surgery. RESULTS: Surgical procedures including pneumoretinopexy, pars plana vitrectomy with gas or silicone oil tamponade with or without laser therapy around the macular hole, and macular buckling have been the primary treatment choices. New techniques, including internal limiting membrane or epiretinal membrane pe…

medicine.medical_specialtygenetic structureshighly myopic eyeEndotamponadeOphthalmologic Surgical ProceduresRetinal detachment surgeryOphthalmologymedicineHumansMacular holetreatmentbusiness.industryRetinal DetachmentRetinal detachmentGeneral Medicinemedicine.diseaseRetinal Perforationseye diseasesmacular holeOphthalmologyCurrent managementMyopia DegenerativeRetinal Perforationsense organsbusinessOphthalmologic Surgical ProcedureHuman
researchProduct

Ortokeratoloģijas ietekme uz acs garuma un refrakcijas izmaiņām bērniem ar miopiju

2017

Darbs uzrakstīts angļu valodā uz 68 lapaspusēm, satur 17 attēlus, 10 tabulas un 73 literatūras atsauces. Darba mērķis bija salīdzināt acu aksiālā garuma un refrakcijas izmaiņas divām grupām tuvredzīgo jauniešu. Vienai grupai tuvredzība tika koriģēta ar ortokeratoloģiskajām kontaktlēcām (OK), bet otrajai ar brillēm. Pēc 18 mēnešiem tuvredzīgo pacientu grupai koriģētai ar brillēm acs aksiālais garums vidēji palielinājās par 0,20 mm, turpretī pacientiem koriģētiem ar OK kontaktlēcām tas bija tikai 0,05 mm. Pacientu grupai koriģētai ar OK kontaktlēcām tuvredzības pieaugums vidēji bija tikai -0,04 D, bet pacientiem koriģētiem ar brillēm tas bija -0,40 D. Refrakcijas izmaiņu atšķirība 0,36 D bija…

myopic progressionrefraction spherical equivalentorthokeratologymyopiaOptometrijaeye axial length
researchProduct