Search results for "myopia"

showing 10 items of 165 documents

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.

2013

The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…

AdultCorneal Wavefront Aberrationgenetic structuresComputer sciencebusiness.industrymedicine.medical_treatmentVisual AcuityIntraocular lenseye diseasesOphthalmologySpherical aberrationOpticsLens Implantation IntraocularmedicineMyopiaOptometryOftalmologíaHumanssense organsbusinessAdaptive opticsOptometryÓpticaClinicalexperimental optometry
researchProduct

Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK

2018

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…

AdultCorneal surgery laserIntraocular pressuremedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPaquimetria corneanagenetic structuresIntraocular pressuremedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityLentes de contatoKeratomileusisCorneal endothelial cell losslaw.invention03 medical and health sciencesCorneal pachymetry0302 clinical medicinePerda de células endoteliais da córneaPressão intraocularlcsh:OphthalmologylawOphthalmologyMyopiaHumansMedicineContact lensesCorneal pachymetryCirurgia da córnea a laserRetrospective Studiesmedicine.diagnostic_testbusiness.industryCorneal TopographyLASIKGeneral MedicineContact Lenses HydrophilicCorneal topographyeye diseasesLens (optics)Contact lensOphthalmologylcsh:RE1-994030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Parasitic myomas after laparoscopic surgery: an emerging complication in the use of morcellator? Description of four cases

2011

Objective To report the development of parasitic myomas after the use of a morcellator. Design Retrospective study. Setting Tertiary care referral center for the treatment of benign gynecologic pathologies. Patient(s) Women undergoing surgery for uterine fibroids. Intervention(s) Chart review. Main Outcome Measure(s) Presence of parasitic leiomyomas. Result(s) We identified four cases of parasitic myomas over the 3-year study period. Two out of the four were symptomatic. The prevalence of this complication, considering all women with whom the electric morcellator was used (n = 423) was 0.9% (95% CI, 0.3–2.2%). Considering exclusively the women who underwent myomectomy (n = 321), it was 1.2%…

AdultLaparoscopic surgerymedicine.medical_specialtyTime FactorsFibroidUterine fibroidsBiopsymedicine.medical_treatmentIatrogenic DiseaselaparoscopyFibroid laparoscopy leiomyoma morcellator parasitic myopia.Gynecologic Surgical ProceduresNeoplasm Seedingleiomyomaparasitic myopiamedicineHumansLaparoscopyPeritoneal NeoplasmsRetrospective StudiesAbdominopelvic cavityFibroid laparoscopy leiomyoma morcellator parasitic myomamedicine.diagnostic_testmorcellatorbusiness.industryObstetrics and GynecologyRetrospective cohort studyEquipment DesignMiddle AgedSurgical Instrumentsmedicine.diseaseMagnetic Resonance ImagingSurgeryLeiomyomaReproductive MedicineUterine NeoplasmsFemaleMorcellatorbusinessComplication
researchProduct

Corrigendum to “Short-term changes in light distortion in orthokeratology subjects"

2015

Artigo completo publicado na revista "BioMed Research International, (2015), 1-7" e disponível no RepositóriUM em: http://hdl.handle.net/1822/33375

AdultMaleAdolescentLightmedicine.medical_treatmentVisual AcuityLentes de contactolcsh:MedicineBioinformaticsGeneral Biochemistry Genetics and Molecular BiologyContrast SensitivityCorneaYoung AdultDistortionMyopiamedicineHumansÓpticaScience & TechnologyGeneral Immunology and Microbiologybusiness.industrylcsh:ROrthokeratologyCorneal TopographyGeneral MedicineRefractive ErrorsTerm (time)OptometryFemaleCorrigendumbusinessOrthokeratologic Procedures
researchProduct

Associations of reading posture, gaze angle and reading distance with myopia and myopic progression

2016

Purpose To study the associations of habitual reading posture, gaze angle in reading and reading distance with myopia and changes in myopia among myopic children. Methods A total of 240 myopic schoolchildren (mean age 10.9 years), with no previous spectacles, were recruited during 1983–1984 to a randomized 3-year clinical trial of bifocal treatment of myopia. Three annual examinations with subjective cycloplegic refraction were conducted for 237–238 subjects. A further examination was conducted at the mean age of 23.2 years for 178 subjects. Habitual reading posture was elicited by questionnaire at study outset. Reading distance was measured with a Clement Clark accommodometer and gaze angl…

AdultMaleAdolescentgenetic structuresmedia_common.quotation_subjectPosturegaze directionReading distanceSpherical equivalentFixation OcularRefraction OcularSittingYoung Adult03 medical and health sciencesSchool nurse0302 clinical medicinereading distanceSurveys and QuestionnairesReading (process)MyopiaHumansYoung adultChildmedia_commonmyopic progressionreading postureDistance PerceptionAccommodation OcularSitting postureta3142General MedicineGazeeye diseasesta3125OphthalmologyEyeglassesReadingDisease ProgressionVisual Perception030221 ophthalmology & optometryOptometryFemalesense organsPsychology030217 neurology & neurosurgeryheightFollow-Up StudiesActa Ophthalmologica
researchProduct

Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability

2001

Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…

AdultMaleBiometryLightInterobserver reliabilityAnterior ChamberEmmetropiaData descriptionCorneaOptical biometryOpticsMyopiaHumansReliability (statistics)AgedMathematicsObserver VariationReproducibilitybusiness.industryCorneal TopographyReproducibility of ResultsMiddle AgedSensory SystemsOphthalmologyInterferometryPartial coherence interferometryFemaleSurgerybusinessNuclear medicinePartial coherenceJournal of Cataract and Refractive Surgery
researchProduct

Myopia and Cognitive Performance: Results From the Gutenberg Health Study.

2016

Purpose To analyze the association between myopia and cognitive performance. Methods A cohort of the population-based Gutenberg Health Study included 3819 eligible enrollees between 40 and 79 years. We used the Tower of London (TOL) test to assess cognitive performance. Myopia was defined as a spherical equivalent (SE) ≤ -0.5 diopters (D) via noncycloplegic autorefractometry. We conducted linear mixed models with the SE as the dependent variable and the age, sex, duration of education, and TOL score as covariates. Results Complete data were available for 3452 participants (90.4%). The mean TOL score was 14.0 ± 3.9 in the myopes versus 12.9 ± 4.0 in the nonmyopes (P < 0.001). The mean TOL sc…

AdultMaleComplete datamedicine.medical_specialtyTime Factorsgenetic structuresPopulationRefraction Ocular03 medical and health sciences0302 clinical medicineCognitionOphthalmologyGermanymedicineMyopiaPrevalenceHumansEffects of sleep deprivation on cognitive performanceProspective StudiesProspective cohort studyeducationDioptreAgededucation.field_of_studybusiness.industryHigh myopiaCognitionMiddle Agedeye diseasesPopulation SurveillanceCohort030221 ophthalmology & optometryOptometryEducational StatusFemalebusiness030217 neurology & neurosurgeryFollow-Up StudiesInvestigative ophthalmologyvisual science
researchProduct

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

2015

Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…

AdultMaleEffects of long-term contact lens wear on the corneaMaterials sciencegenetic structuresCorneal PachymetryScheimpflug principleVisual AcuityCurvatureCorneaYoung AdultOpticsCorneamedicineMyopiaHumansCorneal pachymetryDisposable Equipmentmedicine.diagnostic_testbusiness.industryCorneal TopographyGeneral MedicineOrgan SizeCorneal topographyContact Lenses Hydrophiliceye diseasesCircadian RhythmContact lensOphthalmologymedicine.anatomical_structureFemalesense organsDisposable EquipmentbusinessBiomedical engineeringEuropean journal of ophthalmology
researchProduct

Myopia, use of eyes, and living habits among men aged 33-37 years

2009

As a part of a more extensive research project on health and functional capacity among a representative sample of men, the living habits and backgrounds of myopic men between 33 and 37 years of age living in the town of Jyväskylä were studied in comparison with non-myopic men of the same age. The prevalence of a negative spheric equivalent, which was considered as a criterion of myopia, was 25%. It was found that the myopic, on the average, had been more interested in reading from childhood onwards, their educational and occupational status were higher, and their body structure was lighter. As children they had taken less physical exercise, but as adults no difference was found in physical …

AdultMaleGerontologygenetic structuresLife styleOccupational prestigemedia_common.quotation_subjectPhysical ExertionPhysical exerciseGeneral Medicineeye diseasesOphthalmologySocioeconomic FactorsReading (process)MyopiaEducational StatusHumansOptometrysense organsOccupationsPsychologyLife Stylemedia_commonActa Ophthalmologica
researchProduct