Search results for "myopia"
showing 10 items of 165 documents
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.
2013
The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…
Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK
2018
ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…
Parasitic myomas after laparoscopic surgery: an emerging complication in the use of morcellator? Description of four cases
2011
Objective To report the development of parasitic myomas after the use of a morcellator. Design Retrospective study. Setting Tertiary care referral center for the treatment of benign gynecologic pathologies. Patient(s) Women undergoing surgery for uterine fibroids. Intervention(s) Chart review. Main Outcome Measure(s) Presence of parasitic leiomyomas. Result(s) We identified four cases of parasitic myomas over the 3-year study period. Two out of the four were symptomatic. The prevalence of this complication, considering all women with whom the electric morcellator was used (n = 423) was 0.9% (95% CI, 0.3–2.2%). Considering exclusively the women who underwent myomectomy (n = 321), it was 1.2%…
Corrigendum to “Short-term changes in light distortion in orthokeratology subjects"
2015
Artigo completo publicado na revista "BioMed Research International, (2015), 1-7" e disponível no RepositóriUM em: http://hdl.handle.net/1822/33375
Associations of reading posture, gaze angle and reading distance with myopia and myopic progression
2016
Purpose To study the associations of habitual reading posture, gaze angle in reading and reading distance with myopia and changes in myopia among myopic children. Methods A total of 240 myopic schoolchildren (mean age 10.9 years), with no previous spectacles, were recruited during 1983–1984 to a randomized 3-year clinical trial of bifocal treatment of myopia. Three annual examinations with subjective cycloplegic refraction were conducted for 237–238 subjects. A further examination was conducted at the mean age of 23.2 years for 178 subjects. Habitual reading posture was elicited by questionnaire at study outset. Reading distance was measured with a Clement Clark accommodometer and gaze angl…
Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability
2001
Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…
Myopia and Cognitive Performance: Results From the Gutenberg Health Study.
2016
Purpose To analyze the association between myopia and cognitive performance. Methods A cohort of the population-based Gutenberg Health Study included 3819 eligible enrollees between 40 and 79 years. We used the Tower of London (TOL) test to assess cognitive performance. Myopia was defined as a spherical equivalent (SE) ≤ -0.5 diopters (D) via noncycloplegic autorefractometry. We conducted linear mixed models with the SE as the dependent variable and the age, sex, duration of education, and TOL score as covariates. Results Complete data were available for 3452 participants (90.4%). The mean TOL score was 14.0 ± 3.9 in the myopes versus 12.9 ± 4.0 in the nonmyopes (P < 0.001). The mean TOL sc…
Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.
2015
Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…
Myopia, use of eyes, and living habits among men aged 33-37 years
2009
As a part of a more extensive research project on health and functional capacity among a representative sample of men, the living habits and backgrounds of myopic men between 33 and 37 years of age living in the town of Jyväskylä were studied in comparison with non-myopic men of the same age. The prevalence of a negative spheric equivalent, which was considered as a criterion of myopia, was 25%. It was found that the myopic, on the average, had been more interested in reading from childhood onwards, their educational and occupational status were higher, and their body structure was lighter. As children they had taken less physical exercise, but as adults no difference was found in physical …