Search results for "myopia"

showing 10 items of 165 documents

Refractive lens exchange with the Acri. Twin asymmetric diffractive bifocal intraocular lens system

2009

PURPOSE To evaluate efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had implantation of asymmetric Acri.Twin bifocal diffractive intraocular lenses. METHODS The study comprised 130 eyes of 65 consecutive patients after RLE who had bilateral implantation of the Acri.Twin system. Eyes were divided into myopic and hyperopic groups. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.99 for myopic and 0.93 for hyperopic patients at …

AdultMaleReoperationmedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIn patientProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryPresbyopiaGeneral MedicinePresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyHyperopiaIntraocular lenses030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Comparison of short-term light disturbance, optical and visual performance outcomes between a myopia control contact lens and a single-vision contact…

2020

Purpose To compare the optical and visual performance of a dual-focus (DF) contact lens used for myopia control with a single-vision (SV) contact lens of the same material. Methods A randomised, double-masked crossover study. Twenty-eight healthy, myopic volunteers between 18 and 32 years of age (23.49 +/- 4.07 years) participated in this study. The sensory dominant eye for distance vision was determined. Refraction, best-corrected visual acuity (VA) and aberrations for 3 mm and 5 mm pupil diameters were quantified without a contact lens in situ. Subjects were fitted with two contact lens designs: DF and SV, both made of omafilcon A material. The Quality of Vision (QoV) questionnaire, over-…

AdultMaleTime FactorsAdolescentgenetic structuresVisual qualityControl (management)Visual AcuityVisual performanceLight disturbanceContrast Sensitivity03 medical and health sciencesYoung Adult0302 clinical medicineDouble-Blind MethodMyopiaHumansMiSightCross-Over StudiesScience & TechnologyColor VisionMultifocal contact lensContact Lenses HydrophilicSensory Systemseye diseasesTerm (time)Contact lensOphthalmologyScholarship030221 ophthalmology & optometryOptometryFemalePsychology030217 neurology & neurosurgeryMyopia controlOptometryFollow-Up Studies
researchProduct

Assessment of corneal morphological changes induced by the use of daily disposable contact lenses.

2015

To assess the effect of different disposable soft contact lenses upon corneal thickness, and upon anterior and posterior corneal curvatures using a dual-Scheimpflug imaging based device.Twenty-eight young, healthy subjects wore four different types of daily disposable soft contact lenses on four different days: Dailies Total1, Proclear 1 Day, Clariti 1-Day and 1-Day Acuvue Moist. The lenses had different material and water content. Pachymetry maps and keratometry values were obtained using the Galilei G4 twice a day: one before putting the lens on and one after an eight-hour period of contact-lens wear. Measurements were also recorded without any contact lenses being worn during a day.Clari…

AdultMaleVisual Acuitylaw.inventionCorneaYoung AdultlawMyopiaMedicineHumansDisposable EquipmentKeratometerCorneal curvaturebusiness.industryHealthy subjectsCorneal TopographyGeneral MedicineEquipment DesignContact Lenses Hydrophiliceye diseasesContact lensLens (optics)OphthalmologyOptometryDaily disposableFemalesense organsThickeningbusinessOptometryFollow-Up StudiesContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Long-term comparison of corneal aberration changes after laser in situ keratomileusis: mechanical microkeratome versus femtosecond laser flap creatio…

2010

Purpose To compute and compare visual acuity, refractive outcomes, and anterior corneal aberration changes after myopic laser in situ keratomileusis (LASIK) with flap creation by a mechanical microkeratome and by a femtosecond laser. Setting Private practice refractive surgery center, Valencia, Spain. Design Comparative case series. Methods Patients were assigned to have LASIK flap creation with a mechanical microkeratome (Carriazo-Barraquer) or a femtosecond laser (IntraLase). The Visx S2 excimer laser was used for myopic ablation in all cases. Main outcome measures included uncorrected and corrected distance visual acuities and the defocus equivalent. Higher-order aberrations (HOAs) were …

AdultMaleVisual acuityCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentCorneal StromaKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSurgical FlapsYoung AdultPostoperative ComplicationsMicrokeratomeRefractive surgeryCorneamedicineMyopiaHumansProspective Studiesmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyMiddle AgedCorneal topographyeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structurePrivate practiceOptometrySurgeryFemalesense organsmedicine.symptombusinessFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Diurnal variations in visual performance for disposable contact lenses.

2013

The purpose of this study is to compare the visual performance provided by different daily disposable contact lenses and to analyze its variation over time.Visual performance was evaluated in terms of visual acuity (VA) and contrast sensitivity (CS) in 15 myopic subjects (-0.50 to -4.00 diopters) who had been previously fitted with each one of the following seven types of soft contact lenses: DAILIES TOTAL1 (Alcon, Forth Worth, TX), DAILIES AquaComfort Plus (Alcon), 1-DAY ACUVUE TruEye (JohnsonJohnson Vision Care, Jacksonville, FL), 1-DAY ACUVUE MOIST (JohnsonJohnson Vision Care), SofLens daily disposable (BauschLomb, Rochester, NY), Proclear 1 Day (CooperVision, Fairport, NY), and Clariti …

AdultMaleVisual acuitygenetic structuresmedia_common.quotation_subjectVisual AcuityContrast SensitivityYoung AdultmedicineMyopiaContrast (vision)HumansDisposable EquipmentVision Ocularmedia_commonMathematicsContact Lenses Hydrophiliceye diseasesCircadian RhythmOphthalmologyOptometryDaily disposableFemalesense organsDisposable Equipmentmedicine.symptomOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Objective analysis of contact lens fit.

2015

Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p 0.05). The 95% conf…

AdultMalegenetic structuresObjective analysisObjective assessmentCorneaDouble-Blind MethodStatisticsMyopiaHumansMathematicsFit/gap analysisBlinkingbusiness.industryObjective measurementReproducibility of ResultsGeneral MedicineRepeatabilityEquipment DesignContact Lenses HydrophilicCentrationConfidence intervalContact lensOphthalmologyFemaleNuclear medicinebusinessOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.

2013

PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …

AdultMalemedicine.medical_specialtyBiopticsOptics and PhotonicsPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentImplantable Collamer Lens (ICL)Keratomileusis Laser In SituVisual AcuityKeratomileusisAstigmatismExcimerPhakic intraocular lensRefraction OcularPhotorefractive KeratectomyCellular and Molecular NeuroscienceYoung AdultOpticsBioptics (surgery)Lens Implantation IntraocularOphthalmologymedicineMyopiaHumansDioptreImplantable collamer lensScience & TechnologyExcimer laserbusiness.industryAstigmatismMiddle Agedmedicine.diseaseSensory SystemsPhotorefractive keratectomyeye diseasesOphthalmologyImplantable Collamer LensTreatment OutcomeFemalebusinessGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
researchProduct

Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes

2011

Purpose To evaluate visual acuity, refractive outcomes, and anterior corneal higher-order aberrations (HOAs) after myopic laser in situ keratomileusis (LASIK) with uneventful single femtosecond laser pass versus double pass performed for intraoperative suction loss. Setting Private refractive surgery center, Valencia, Spain. Design Cohort study. Methods After the LASIK flap was created with a single pass of an Intralase femtosecond laser in 1 eye and a double pass in the fellow eye, the ablation was performed with a Visx S2 laser. At 12 months, the refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and anterior corneal HOAs were measured with 4.0 mm and 6.0 mm pup…

AdultMalemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuitygenetic structuresCorneal Stromamedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSurgical Flapslaw.inventionCohort StudiesYoung AdultlawRefractive surgeryOphthalmologyMyopiamedicineHumansDioptreRetrospective Studiesbusiness.industryLASIKMiddle AgedLaserAblationeye diseasesSensory SystemsSurgeryOphthalmologyTreatment OutcomeFemtosecondFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.

2006

ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…

AdultMalemedicine.medical_specialtyCorneal endotheliumBiometrygenetic structuresScheimpflug principleIrisAnterior surfacePhakic intraocular lensRefraction Ocularlaw.inventionLens Implantation IntraocularlawAnterior Eye SegmentCorneaOphthalmologyLens CrystallinemedicineMyopiaPhotographyHumansIris (anatomy)Retrospective StudiesLenses Intraocularbusiness.industrySuture Techniqueseye diseasesLens (optics)Ophthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Corneal Biomechanical Parameters With Corneoscleral Contact Lenses in Post-Laser In Situ Keratomileusis Eyes

2018

Objective: To evaluate corneal biomechanical parameters wearing corneoscleral contact lenses (CScL) in patients with irregular corneas after laser in situ keratomileusis (LASIK). Methods: Data from patients fitted with CScL because of corneal surface irregularities after complicated LASIK surgery were selected by two eye clinics. Previously and after 1 year of CScL fitting, corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc), and central corneal thickness were evaluated. In addition, visual acuity, subjective comfort, and wearing time CScL were reported. Results: The study comprised 27 eyes. Statistically significant differences were fo…

AdultMalemedicine.medical_specialtyIntraocular pressureCorneal Wavefront AberrationVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityCorneal resistance factorKeratomileusisLASIKCorneaCorneal hysteresis03 medical and health sciences0302 clinical medicineOphthalmologyMyopiamedicineHumansIn patientCorneal surfaceRefractive surgeryIntraocular PressureRetrospective Studiesbusiness.industryLASIKCorneal hysteresisContact Lenses Hydrophiliceye diseasesBiomechanical PhenomenaScleraOphthalmologymedicine.anatomical_structureCorneoscleral contact lensesPatient Satisfaction030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessSclera030217 neurology & neurosurgery
researchProduct