Search results for "nema"
showing 10 items of 1972 documents
Arm end-point trajectories under normal and micro-gravity environments.
2001
Abstract The purpose of the present experiment was to study the way in which the CNS represents gravitational force during vertical arm pointing movements. Movements in upward and downward directions were executed by two cosmonauts in normal-gravity and weightlessness. Analyses focused upon finger kinematics in the sagittal plane. In normal-gravity, downward direction movements showed smaller curvatures and greater relative times to peak velocity ( AT MT ) when compared with upward direction movements. Data from the weightlessness experiments showed that whilst downward movements decreased their curvature during space flight, curvatures of upward movements changed slightly. Furthermore, AT …
Dog sperm swimming parameters analysed by computer-assisted semen analysis of motility reveal major breed differences
2019
Dogs have undergone an intensive artificial selection process ever since the beginning of their relationship with humans. As a consequence, a wide variety of well-defined breeds exist today. Due to the enormous variation in dog phenotypes and the unlikely chance of gene exchange between them, the question arises as to whether they should still be regarded as a single species or, perhaps, they be considered as different taxa that possess different reproductive traits. The aim of this study was therefore to characterize some male reproductive traits, focusing on kinematic characteristics of dog spermatozoa from several breeds. Thirty-seven dogs from the following breeds were used: Staffordshi…
The helminth community of the wood mouse Apodemus sylvaticus from the Erro River valley, Navarre, Spain.
2014
AbstractThe helminth fauna of the wood mouse,Apodemus sylvaticus, in the Erro River valley (Navarre, Spain) was investigated from a total of 150 mice between February 2001 and July 2002. An overall prevalence of 90.7% was recorded and up to 14 helminth species identified. The most prevalent species was the nematodeHeligmosomoidespolygyrus(78.0%), whereasSyphacia stromawas the species with the highest median abundance (19.8). The detection ofCalodium hepaticum,Rodentolepis stramineaand the larvae ofHydatigera taeniaeformisare significant, since these helminth species could be considered potential human parasites. The helminth infracommunity comprised no more than five species. A significant …
Human toxocariasis: a report of nine cases
2008
Aim: Human toxocariasis is caused by infection with the larval stage of nematode parasites of dogs and cats, Toxocara canis or Toxocara cati. These helminths are not able to complete their life cycle in undefinitive hosts and so undergo aberrant migrations in the tissues causing a wide spectrum of signs and symptoms. Eosinophilia is often severe and sometimes represents the only sign of infection, except in ocular and neurological forms. Methods: We describe the clinical features of nine children affected by toxocariasis admitted to our Infectious Diseases department from 2004 to 2006. Results: Fever and hepatomegaly were the most common clinical findings. In two cases eosinophilia was not …
CASA-Mot technology: how results are affected by the frame rate and counting chamber.
2017
For over 30 years, CASA-Mot technology has been used for kinematic analysis of sperm motility in different mammalian species, but insufficient attention has been paid to the technical limitations of commercial computer-aided sperm analysis (CASA) systems. Counting chamber type and frame rate are two of the most important aspects to be taken into account. Counting chambers can be disposable or reusable, with different depths. In human semen analysis, reusable chambers with a depth of 10 µm are the most frequently used, whereas for most farm animal species it is more common to use disposable chambers with a depth of 20 µm . The frame rate was previously limited by the hardware, although chang…
The Relation between Geometry and Time in Mental Actions
2012
Mental imagery is a cognitive tool that helps humans take decisions by simulating past and future events. The hypothesis has been advanced that there is a functional equivalence between actual and mental movements. Yet, we do not know whether there are any limitations to its validity even in terms of some fundamental features of actual movements, such as the relationship between space and time. Although it is impossible to directly measure the spatiotemporal features of mental actions, an indirect investigation can be conducted by taking advantage of the constraints existing in planar drawing movements and described by the two-thirds power law (2/3PL). This kinematic law describes one of th…
Kinematics of obstacle clearance in the rat
2010
Although the rat has become the favourite animal model in preclinical research on locomotion, studies designed to assess the strategy used by rats to avoid obstacle are lacking. Using an optoelectronic 3D motion analysis system, we therefore, compared the step pattern, timing and length variables of locomotor cycles, trajectories and joint angles of limbs when rats step between and over obstacles (3 cm-high) fixed on a treadmill belt (25 cm/s). Motion in all four limbs of adult animals with an initial age of 11 weeks was serially recorded for a period of 10 weeks. The results showed that obstacle clearance is associated with the reorganization of the basic step pattern resulting in increase…
Dynamic thoracohumeral kinematics are dependent upon the etiology of the shoulder injury.
2017
[EN] Obtaining kinematic patterns that depend on the shoulder injury may be important when planning rehabilitation. The main goal of this study is to explore whether the kinematic patterns of continuous and repetitive shoulder elevation motions are different according to the type of shoulder injury in question, specifically tendinopathy or rotator cuff tear, and to analyze the influence of the load handled during its assessment. For this purpose, 19 individuals with tendinopathy and 9 with rotator cuff tear performed a repetitive scaption movement that was assessed with stereophotogrammetry. Furthermore, static range of motion (ROM) and isometric strength were evaluated with a goniometer an…
Test-retest reliability of 3D kinematic gait variables in hip osteoarthritis patients
2011
Import JabRef | WosArea Orthopedics; Rheumatology; International audience; Objectives: (1) to investigate the test-retest reliability of 3D gait analysis (3DGA) in hip Osteoarthritis (OA) patients; (2) to find the minimum number of gait trials needed to overcome intrinsic variability; (3) to check the accuracy of angles measured by the 3D system. Design: 23 Patients suffering from hip OA with no other major disease were recruited. We evaluated the reliability of spatio-temporal variables and body angles (lower-limb joints, trunk and pelvis angles) during two sessions of 3DGA using intra-class correlation coefficients (ICC). The minimum number of trials needed to overcome intrinsic variabili…
Sperm kinematic subpopulations of the American crocodile (Crocodylus acutus)
2021
There has been very limited use of computer assisted semen analysis (CASA) to evaluate reptile sperm. The aim of this study was to examine sperm kinematic variables in American crocodile (Crocodylus acutus) semen samples and to assess whether sperm subpopulations could be characterized. Eight ejaculates (two ejaculates/male) from four sexually mature captive crocodiles were obtained. An ISAS®v1 CASA-Mot system, with an image acquisition rate of 50 Hz, and ISAS®D4C20 counting chambers were used for sperm analyses. The percentages of motile and progressively motile spermatozoa did not differ among animals (P > 0.05) but there was a significant animal effect with regards to kinematic variables…