Search results for "nucl-ex"

showing 10 items of 1009 documents

Dawning of the N=32 shell closure seen through precision mass measurements of neutron-rich titanium isotopes

2018

A precision mass investigation of the neutron-rich titanium isotopes 51 − 55 Ti was performed at TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the N = 32 shell closure, and the overall uncertainties of the 52 − 55 Ti mass values were significantly reduced. Our results conclusively establish the existence of the weak shell effect at N = 32 , narrowing down the abrupt onset of this shell closure. Our data were compared with state-of-the-art ab initio shell model calculations which, despite very successfully describing where the N = 32 shell gap is strong, overpredict its strength and extent in titanium and heavier isotones. These measurements a…

Materials scienceNuclear Theorynucl-thNuclear TheoryAb initioGeneral Physics and Astronomychemistry.chemical_elementFOS: Physical sciences[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometrynucl-ex01 natural sciencesNuclear Theory (nucl-th)symbols.namesake0103 physical sciencesPhysics::Atomic and Molecular ClustersNeutron[ PHYS.NEXP ] Physics [physics]/Nuclear Experiment [nucl-ex]Nuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentNuclear ExperimentIsotope010308 nuclear & particles physicsStarke Wechselwirkung und exotische Kerne – Abteilung BlaumPenning trapchemistry13. Climate actionsymbolsIon trapAtomic physicsTitan (rocket family)Titanium
researchProduct

Extending the applicability of an open-ring trap to perform experiments with a single laser-cooled ion.

2015

An open-ring ion trap, also referred to as transparent trap was initially built up to perform $\beta$-$\nu$ correlation experiments with radioactive ions. This trap geometry is also well suited to perform experiments with laser-cooled ions, serving for the development of a new type of Penning trap, in the framework of the project TRAPSENSOR at the University of Granada. The goal of this project is to use a single $^{40}$Ca$^+$ ion as detector for single-ion mass spectrometry. Within this project and without any modification to the initial electrode configuration, it was possible to perform Doppler cooling on $^{40}$Ca$^+$ ions, starting from large clouds and reaching single ion sensitivity.…

Materials sciencePhysics - Instrumentation and DetectorsIon beam[PHYS.PHYS.PHYS-ATOM-PH]Physics [physics]/Physics [physics]/Atomic Physics [physics.atom-ph]010308 nuclear & particles physicsAtomic Physics (physics.atom-ph)FOS: Physical sciencesInstrumentation and Detectors (physics.ins-det)Penning trapMass spectrometry01 natural sciencesIonPhysics - Atomic PhysicsTrap (computing)Physics::Plasma PhysicsLaser cooling0103 physical sciencesIon trapPhysics::Atomic PhysicsAtomic physicsNuclear Experiment (nucl-ex)010306 general physicsInstrumentationNuclear ExperimentDoppler coolingThe Review of scientific instruments
researchProduct

Do nuclei go pear-shaped? Coulomb excitation of 220Rn and 224Ra at REX-ISOLDE (CERN)

2014

Artículo escrito por muchos autores, sólo se referencian el primero, los autores que firman como Universidad Autónoma de Madrid y el grupo de colaboración en el caso de que aparezca en el artículo

Materials scienceta114PhysicsQC1-999Coulomb excitationREX-ISOLDEFísicaradon[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energyNucleiradiumNuclear magnetic resonancePhysics::Accelerator PhysicsGamma spectroscopypear-shaped nuclei
researchProduct

Nuclear charge radii of potassium isotopes beyond N=28

2014

We report on the measurement of optical isotope shifts for 38, 39, 42, 44, 46–51 K relative to 47 K from which changes in the nuclear mean square charge radii across the N = 28 shell closure are deduced. The investigation was carried out by bunched-beam collinear laser spectroscopy at the CERN-ISOLDE radioactive ion-beam facility. Mean square charge radii are now known from 37K to 51K, covering all ν f7/2-shell as well as all νp3/2-shell nuclei. These measurements, in conjunction with those of Ca, Cr, Mn and Fe, provide a first insight into the Z dependence of the evolution of nuclear size above the shell closure at N = 28

Mean squareNuclear and High Energy PhysicsPotassiumCollinear laser spectroscopyNuclear TheoryShell (structure)FOS: Physical scienceschemistry.chemical_elementEffective nuclear chargeNuclear Physics - ExperimentNuclear Experiment (nucl-ex)SpectroscopyNuclear ExperimentNuclear ExperimentPhysicsIsotopeCharge (physics)Physique atomique et nucléaireIsotope shiftchemistryIsotopes of potassiumPotassiumPhysics::Accelerator PhysicsAtomic physicsPräzisionsexperimente - Abteilung BlaumNuclear charge radius
researchProduct

Electromagnetic properties of low-lying states in neutron-deficient Hg isotopes: Coulomb excitation of Hg-182, Hg-184, Hg-186 and Hg-188

2019

The neutron-deficient mercury isotopes serve as a classical example of shape coexistence, whereby at low energy near-degenerate nuclear states characterized by different shapes appear. The electromagnetic structure of even-mass 182-188 Hg isotopes was studied using safe-energy Coulomb excitation of neutron-deficient mercury beams delivered by the REX-ISOLDE facility at CERN. The population of $ 0^{+}_{1,2}$01,2+, $ 2^{+}_{1,2}$21,2+and $ 4^{+}_{1}$41+states was observed in all nuclei under study. Reduced E2 matrix elements coupling populated yrast and non-yrast states were extracted, including their relative signs. These are a sensitive probe of shape coexistence and may be used to validate…

MomentsIntruder01 natural sciencesMOMENTSNuclear ExperimentPhysicseducation.field_of_studyYrastBohr modelLIFETIMESddc:Mean field theorysymbolsFísica nuclearAtomic physicsydinfysiikkaConfigurationNuclear and High Energy PhysicsELECTRIC-MONOPOLE TRANSITIONS3106PopulationElectric-monopole transitionsDEFORMED BANDSLifetimesCoulomb excitationNUCLEAR[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]114 Physical sciencessymbols.namesakeIsomerismSHAPE COEXISTENCE0103 physical sciencesNuclear fusionNuclear Physics - ExperimentNeutronNuclear010306 general physicseducationCONFIGURATIONDeformed bands010308 nuclear & particles physicsINTRUDERShape coexistence2207 Física Atómica y NuclearDecayPhysics and Astronomy13. Climate actionISOMERISMInteracting boson modelDECAY
researchProduct

Mass measurements towards doubly magic Ni-78 : Hydrodynamics versus nuclear mass contribution in core-collapse supernovae

2022

International audience; We report the first high-precision mass measurements of the neutron-rich nuclei 74,75Ni and the clearly identified ground state of 76Cu, along with a more precise mass-excess value of 78Cu, performed with the double Penning trap JYFLTRAP at the Ion Guide Isotope Separator On-Line (IGISOL) facility. These new results lead to a quantitative estimation of the quenching for the N=50 neutron shell gap. The impact of this shell quenching on core-collapse supernova dynamics is specifically tested using a dedicated statistical equilibrium approach that allows a variation of the mass model independent of the other microphysical inputs. We conclude that the impact of nuclear m…

NUCLEOSYNTHESISIONSCore-collapse supernovaNuclear and High Energy PhysicsScience & TechnologyIMPACTPhysicsPenning trapR-PROCESSneutronitAstronomy & Astrophysics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]114 Physical sciencesSTATEPhysics Particles & FieldsPhysics NuclearSPECTROMETRYPhysical SciencesISOTOPESNuclear massNuclear Physics - ExperimentydinfysiikkaShell gap
researchProduct

GEANT4 simulation of the neutron background of the C6D6 set-up for capture studies at n_TOF

2014

The neutron sensitivity of the C6D6 detector setup used at n_TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has beeni mplemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with anatC sample, showing an excellent agreement above 1 keV. At lower energies, an additional compo…

Neutron captureNuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaGEANT4 simulations; Neutron time of flight; Neutron background; n_TOF; Neutron captureFOS: Physical sciencesNeutronN-TOF7. Clean energy01 natural sciencesPartícules (Física nuclear)Nuclear physicsCross section (physics)0103 physical sciencesNeutronNuclear Experiment (nucl-ex)010306 general physicsGEANT4 simulations;N-TOF;Neutron time of flight;Neutron capture;Neutron backgroundNuclear ExperimentInstrumentationphysics.ins-detNuclear ExperimentGEANT4Line (formation)Particles (Nuclear physics)PhysicsBonner sphere:Energies::Energia nuclear [Àrees temàtiques de la UPC]NeutronsGEANT4 simulation:Física [Àrees temàtiques de la UPC]010308 nuclear & particles physicsDetectorFísicaNeutron sensitivityDetectorInstrumentation and Detectors (physics.ins-det)Neutron radiationNEUTRON TIME OF FLIGHTNeutron captureBackgroundDeuteriumN_TOFGEANT4 simulationsNeutron backgroundSimulation
researchProduct

Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins

2010

Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.

Neutron electric dipole momentAtomic Physics (physics.atom-ph)FOS: Physical sciences[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Lorentz covariance01 natural sciencesResonance (particle physics)Physics - Atomic PhysicsHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)Quantum mechanics0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]NeutronNuclear Experiment (nucl-ex)Electrical and Electronic Engineering010306 general physicsNuclear ExperimentLarmor precessionPhysics[PHYS.PHYS.PHYS-ATOM-PH]Physics [physics]/Physics [physics]/Atomic Physics [physics.atom-ph]Spins010308 nuclear & particles physicsCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsNeutron spectroscopyUltracold neutrons
researchProduct

Statistical sensitivity of the nEDM apparatus at PSI to n − n′ oscillations

2018

The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron β-decay. Two groups have performed a series of experiments in search of neutron – mirror-neutron (n − n′) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time τnn′. Later, these data sets have been further analyzed by Berezhiani et al.(2009–2017), and signals, compatible with n − n′ oscillations in the presence of mirror magnetic fields, have been reported. The Neutron Electric Dipole Moment Collaboration based at the Paul Scherrer Institute performed a new series of experiments to further test…

Neutron electric dipole momentQC1-999magnetic field[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesmirror particle0103 physical sciencesoverlapNeutronSensitivity (control systems)[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicssterileoscillation: timePhysicsn: electric momentSeries (mathematics)010308 nuclear & particles physicsOscillationPhysicsDegenerate energy levelssensitivityMagnetic fieldComputational physicsNeutron sourcestatisticalperformance
researchProduct

The n2EDM experiment at the Paul Scherrer Institute

2018

We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.

Neutron transportPhysics - Instrumentation and DetectorsNeutron electric dipole momentPhysics::Instrumentation and DetectorsQC1-999FOS: Physical sciences7. Clean energy01 natural sciencesHigh Energy Physics - ExperimentNuclear physicsHigh Energy Physics - Experiment (hep-ex)Chamber design0103 physical sciencesNeutronspectrometer: design[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Nuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentNuclear ExperimentPhysicsn: electric momentSpectrometer010308 nuclear & particles physicsPhysicsInstrumentation and Detectors (physics.ins-det)sensitivityMeasuring instrumentUltracold neutronsNucleonperformanceInternational Workshop on Particle Physics at Neutron Sources 2018, May 2018, Grenoble, France
researchProduct